Thermodynamic performance and CO2 emission analysis of transcritical CO2 two-stage compression refrigeration system with intermediate gas supplementation

被引:0
|
作者
Wang, Youdong [1 ,2 ]
Li, Xiaoqiong [2 ]
Guo, Yanhua [3 ]
Dai, Jian [4 ]
Song, Jitian [1 ]
He, Qing [2 ]
Zhang, Zhentao [2 ]
Xu, Qing [1 ]
Yang, Junling [2 ]
机构
[1] Tianjin Univ Sci & Technol, Coll Mech Engn, Tianjin Key Lab Integrated Design & Online Monitor, Tianjin 300222, Peoples R China
[2] Chinese Acad Sci, Tech Inst Phys & Chem, Beijing 100190, Peoples R China
[3] Huazhong Univ Sci & Technol, Sch Energy & Power Engn, Wuhan 430074, Peoples R China
[4] Nanchang Univ, Sch Civil Engn & Architecture, Nanchang 330031, Peoples R China
关键词
Two-stage compression; Refrigeration system; Intermediate gas supplementation; CO2; emission; Economic cost; HEAT-PUMP SYSTEM; THEORETICAL-ANALYSIS; CYCLE; SIMULATION; ENERGY;
D O I
10.1016/j.energy.2025.135193
中图分类号
O414.1 [热力学];
学科分类号
摘要
Low evaporation temperature characteristic of transcritical CO2 refrigeration systems results in high discharge temperature and decreased system efficiency. In this paper, a transcritical CO2 two-stage compression refrigeration system with intermediate gas supplementation (TCTCRS-IGS) was proposed, and thermodynamic and CO2 emission analysis was conducted. Firstly, the transcritical CO2 two-stage compression refrigeration system (TCTCRS) with and without intermediate gas supplementation was compared. Then, experimental investigations were conducted to analyze the effects of evaporation temperature, high pressure, intermediate pressure, gas cooler outlet temperature, and intermediate cooler outlet temperature. Besides, CO2 emission was analyzed at different conditions. The results show that the TCTCRS-IGS system achieved a 24.73 % reduction in discharge temperature and a 7.42 % increase in COP compared to TCTCRS. Meanwhile, the TCTCRS-IGS system is less affected by the intermediate cooler outlet temperature. However, it is significantly influenced by the other parameters. As the evaporation temperature rises, the cooling capacity and COP improve by 57.7 % and 23.9 %, respectively. The COP shows an initial increase followed by a decrease with high pressure, reaching a maximum value of 1.39. The COP reaches its highest point of 1.5 at an intermediate pressure of 4.2 MPa. As the gas cooler outlet temperature increases, COP initially decrease and then rise. Besides, the CO2 emissions are influenced by evaporation temperature, high pressure, and gas cooler outlet temperature, with little impact from intermediate pressure and cooler outlet temperature. The TCTCRS-IGS system offers economic costs through superior energy efficiency, lowering operating and environmental costs. The TCTCRS-IGS system contributes to the enhancement of the TCTCRS performance, fostering the development of low-carbon technology.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] CO2 transcritical compression/ejection hybrid refrigeration cycle with two evaporators
    Ma, Yitai
    Guan, Haiqing
    Yang, Junlan
    Liu, Shengchun
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2006, 27 (01): : 73 - 77
  • [42] Thermodynamic performance evaluation of an ejector-enhanced transcritical CO2 parallel compression refrigeration cycle
    Bai, Tao
    Shi, Rongxuan
    Yu, Jianlin
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 149 : 49 - 61
  • [43] Thermodynamic evaluation of CO2 transcritical refrigeration cycle with ejector
    Khellaf, Nabil
    Gomri, Rabah
    INTERNATIONAL JOURNAL OF EXERGY, 2016, 19 (02) : 210 - 231
  • [44] Thermodynamics analysis of a modified dual-evaporator CO2 transcritical refrigeration cycle with two-stage ejector
    Bai, Tao
    Yan, Gang
    Yu, Jianlin
    ENERGY, 2015, 84 : 325 - 335
  • [45] Transcritical CO2 system with two-stage throttling for supermarkets: Field tests, energy and emission performance assessment in China
    Liu, Shengchun
    Li, Jiayu
    Dai, Baomin
    Wang, Jiahao
    Zhang, Qitong
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2024, 166 : 159 - 173
  • [46] Performance Analysis of Two-stage Compression CO2 Transcritical Cycle with R290 Mechanical Subcooling Unit
    Lu, Fenping
    Liu, Shengchun
    Dai, Baomin
    Li, Jiayu
    JOINT INTERNATIONAL CONFERENCE ON ENERGY, ECOLOGY AND ENVIRONMENT ICEEE 2018 AND ELECTRIC AND INTELLIGENT VEHICLES ICEIV 2018, 2018,
  • [47] Transcritical CO2 Supermarket Refrigeration
    Weber, Collin
    Horning, Harrison
    ASHRAE JOURNAL, 2015, 57 (10) : 26 - +
  • [48] Performance improvement of a transcritical CO2 refrigeration cycle using two-stage thermoelectric modules in sub-cooler and gas cooler
    Jamali, Siamak
    Yari, Mortaza
    Mohammadkhani, Farzad
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 74 : 105 - 115
  • [49] A CO2 transcritical refrigeration system with ejector and economizer
    Li M.
    Zhan H.
    Wang P.
    Liu X.
    Li Y.
    Ma Y.
    Huagong Xuebao/CIESC Journal, 2021, 72 : 146 - 152
  • [50] Experimental Investigation on Transcritical CO2 Refrigeration System
    Liu, Yingfu
    Shen, Pengyu
    Jin, Guangya