Thermodynamic performance and CO2 emission analysis of transcritical CO2 two-stage compression refrigeration system with intermediate gas supplementation

被引:0
|
作者
Wang, Youdong [1 ,2 ]
Li, Xiaoqiong [2 ]
Guo, Yanhua [3 ]
Dai, Jian [4 ]
Song, Jitian [1 ]
He, Qing [2 ]
Zhang, Zhentao [2 ]
Xu, Qing [1 ]
Yang, Junling [2 ]
机构
[1] Tianjin Univ Sci & Technol, Coll Mech Engn, Tianjin Key Lab Integrated Design & Online Monitor, Tianjin 300222, Peoples R China
[2] Chinese Acad Sci, Tech Inst Phys & Chem, Beijing 100190, Peoples R China
[3] Huazhong Univ Sci & Technol, Sch Energy & Power Engn, Wuhan 430074, Peoples R China
[4] Nanchang Univ, Sch Civil Engn & Architecture, Nanchang 330031, Peoples R China
关键词
Two-stage compression; Refrigeration system; Intermediate gas supplementation; CO2; emission; Economic cost; HEAT-PUMP SYSTEM; THEORETICAL-ANALYSIS; CYCLE; SIMULATION; ENERGY;
D O I
10.1016/j.energy.2025.135193
中图分类号
O414.1 [热力学];
学科分类号
摘要
Low evaporation temperature characteristic of transcritical CO2 refrigeration systems results in high discharge temperature and decreased system efficiency. In this paper, a transcritical CO2 two-stage compression refrigeration system with intermediate gas supplementation (TCTCRS-IGS) was proposed, and thermodynamic and CO2 emission analysis was conducted. Firstly, the transcritical CO2 two-stage compression refrigeration system (TCTCRS) with and without intermediate gas supplementation was compared. Then, experimental investigations were conducted to analyze the effects of evaporation temperature, high pressure, intermediate pressure, gas cooler outlet temperature, and intermediate cooler outlet temperature. Besides, CO2 emission was analyzed at different conditions. The results show that the TCTCRS-IGS system achieved a 24.73 % reduction in discharge temperature and a 7.42 % increase in COP compared to TCTCRS. Meanwhile, the TCTCRS-IGS system is less affected by the intermediate cooler outlet temperature. However, it is significantly influenced by the other parameters. As the evaporation temperature rises, the cooling capacity and COP improve by 57.7 % and 23.9 %, respectively. The COP shows an initial increase followed by a decrease with high pressure, reaching a maximum value of 1.39. The COP reaches its highest point of 1.5 at an intermediate pressure of 4.2 MPa. As the gas cooler outlet temperature increases, COP initially decrease and then rise. Besides, the CO2 emissions are influenced by evaporation temperature, high pressure, and gas cooler outlet temperature, with little impact from intermediate pressure and cooler outlet temperature. The TCTCRS-IGS system offers economic costs through superior energy efficiency, lowering operating and environmental costs. The TCTCRS-IGS system contributes to the enhancement of the TCTCRS performance, fostering the development of low-carbon technology.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] PERFORMANCE ANALYSIS OF TRANSCRITICAL CO2 REFRIGERATION SYSTEM FOR SUPERMARKET APPLICATION
    Santosa, IDewa M. C.
    Sudirman
    Ing, Suta Waisnawa
    INTERNATIONAL JOURNAL OF GEOMATE, 2018, 15 (50): : 70 - 75
  • [22] Numerical simulation of CO2 two-stage compression refrigeration system with external intercooler
    Niu, Heng
    Li, Wuyan
    Xiao, Hansong
    Zhang, Xianpeng
    Zhao, Kai
    Yang, Zixu
    Wang, Baolong
    Shi, Wenxing
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 151 : 14 - 25
  • [23] Performance of a new two-stage multi-intercooling transcritical CO2 ejector refrigeration cycle
    Manjili, F. Eskandari
    Yavari, M. A.
    APPLIED THERMAL ENGINEERING, 2012, 40 : 202 - 209
  • [24] The performance analysis of a two-stage transcritical CO2 cooling cycle with various gas cooler pressures
    Oezguer, Arif Emre
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2008, 32 (14) : 1309 - 1315
  • [25] Thermodynamic performance and the exergy destruction of the transcritical CO2 two-stage compression and ejector expansion direct cooling ice making system
    Li, Wenlong
    Wang, Baodong
    Deng, Jianqiang
    He, Yang
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 151 : 314 - 330
  • [26] Thermodynamic analysis on a two-stage transcritical CO2 heat pump cycle with double ejectors
    Xing, Meibo
    Yu, Jianlin
    Liu, Xiaoqin
    ENERGY CONVERSION AND MANAGEMENT, 2014, 88 : 677 - 683
  • [27] Hybrid two-stage CO2 transcritical mechanical compression-ejector cooling cycle: Thermodynamic analysis and optimization
    Ierin, Volodymyr
    Chen, Guangming
    Volovyk, Oleksii
    Shestopalov, Kostyantyn
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 132 : 45 - 55
  • [28] Second law analysis of two-stage compression transcritical CO2 heat pump cycle
    Oezguer, Arif Emre
    Bayrakci, Hilmi Cenk
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2008, 32 (13) : 1202 - 1209
  • [29] Thermodynamic design and simulation of a CO2 based transcritical vapour compression refrigeration system with an ejector
    Ahammed, Md. Ezaz
    Bhattacharyya, Souvik
    Ramgopal, M.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 45 : 177 - 188
  • [30] Thermodynamic design and simulation of a CO2 based transcritical vapour compression refrigeration system with an ejector
    Ahammed, Md. Ezaz
    Bhattacharyya, Souvik
    Ramgopal, M.