Accuracy and safety of percutaneous pedicle screw placement using the K-wireless minimally invasive spine percutaneous pedicle screw system in Japan: A randomized active controlled study

被引:1
|
作者
Ohmori, Kazuo [1 ]
Terayama, Sei [2 ]
Ono, Koichiro
Sakamoto, Miyuki [3 ]
Horikoshi, Yukie
机构
[1] Nippon Koukan Hosp, Ctr Spinal Surg, 1-2-1 Koukandori,Kawasaki Ku, Kawasaki, Kanagawa, Japan
[2] Shunyokai Cent Hosp, Dept Orthoped Surg, 485 Niitomi, Kimotuki, Kagoshima, Japan
[3] Johnson & Johnson KK, Med Co, 3-5-2 Nishikanda,Chiyoda Ku, Tokyo, Japan
来源
关键词
Randomized controlled trial; K-wireless MIS PPS system; Accuracy of screw insertion; Percutaneous Pedicle Screw; Minimally Invasive Spine; PPS; FIXATION; FUSION;
D O I
10.1016/j.xnsj.2022.100121
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Minimally invasive lumbar fusion has recently become a widely used technique worldwide. This randomized active controlled study was conducted to demonstrate the non-inferiority of the K-wireless Minimally Invasive Spine (MIS) Percutaneous Pedicle Screw (PPS) system compared with use of the six pedicle screw systems currently used in our practices with respect to the accuracy of pedicle screw placement.Also to compare the screw- insertion time and number of fluoroscopic observations during screw insertion between the groups. Methods: A total of 80 patients with degenerative spinal diseases or vertebral fractures were assigned, including 41 patients in the K-wireless MIS PPS system group (K-wireless group) and 39 in the control group (K-wire group). The accuracy of the screw insertion, screw-insertion time, number of fluoroscopic observations during screw insertion, and the incidence of adverse events were compared between the K-wireless group and the K-wire group. The accuracy rate was calculated as the number of screws with no breach divided by the total number of screws. Results: The accuracy rates of screw insertion were 85.7% and 75.0% in the K-wireless and K-wire groups, respectively, with an intergroup difference of 10.7% (95% confidence interval: 2.3-19.1%). The K-wireless group demonstrated non-inferiority compared with the K-wire group. The mean screw-insertion time was significantly shorter in the K-wireless group (2.62 and 2.97 min in the K-wireless and K-wire groups, respectively; P = 0.005). There were also significantly fewer fluoroscopies in the K-wireless group (10.7 and 17.4 in the K-wireless and K-wire groups, respectively; P < 0.001). There were no device-related or study treatment-related adverse events in either group. Conclusions: The accuracy of pedicle screw insertion using the K-wireless MIS PPS system was not inferior to that of existing products. In terms of safety, no product-related or treatment-related adverse events were identified in this study and no new safety concerns were noted.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] The Accuracy and Safety of a Pedicle Screw Using the Freehand Technique in Minimally Invasive Scoliosis Surgery
    Nam, Yunjin
    Chang, Dong-Gune
    Kim, Hong Jin
    Ha Kim, Young
    Lee, Sangmin
    Yang, Jae Hyuk
    Suh, Seung Woo
    NEUROSPINE, 2023, 20 (01) : 240 - 247
  • [22] Minimally Invasive Transforaminal Lumbar Interbody Fusion Using Augmented Reality Surgical Navigation for Percutaneous Pedicle Screw Placement
    Charles, Yann P.
    Cazzato, Roberto L.
    Nachabe, Rami
    Chatterjea, Anindita
    Steib, Jean-Paul
    Gangi, Afshin
    CLINICAL SPINE SURGERY, 2021, 34 (07): : E415 - E424
  • [23] How safe is minimally invasive pedicle screw placement for treatment of thoracolumbar spine fractures?
    Heintel, Timo Michael
    Dannigkeit, Stefan
    Fenwick, Annabel
    Jordan, Martin Cornelius
    Jansen, Hendrik
    Gilbert, Fabian
    Meffert, Rainer
    EUROPEAN SPINE JOURNAL, 2017, 26 (05) : 1515 - 1524
  • [24] How safe is minimally invasive pedicle screw placement for treatment of thoracolumbar spine fractures?
    Timo Michael Heintel
    Stefan Dannigkeit
    Annabel Fenwick
    Martin Cornelius Jordan
    Hendrik Jansen
    Fabian Gilbert
    Rainer Meffert
    European Spine Journal, 2017, 26 : 1515 - 1524
  • [25] Beyond Pedicle Screw Placement: Future Minimally Invasive Applications of Robotics in Spine Surgery
    Bhimreddy, Meghana
    Menta, Arjun K.
    Fuleihan, Antony A.
    Davidar, A. Daniel
    Kramer, Patrick
    Jillala, Ritvik
    Najeed, Mustafa
    Wang, Xihang
    Theodore, Nicholas
    NEUROSURGERY, 2025, 96 (3S) : S94 - S102
  • [26] Percutaneous "K-wireless" pedicle screw fixation technique: an evaluation of the initial experience of 100 screws with assessment of accuracy, radiation exposure, and procedure time
    Spitz, Steven M.
    Sandhu, Faheem A.
    Voyadzis, Jean-Marc
    JOURNAL OF NEUROSURGERY-SPINE, 2015, 22 (04) : 422 - 431
  • [27] Safety and Efficacy of All-In-One Percutaneous Pedicle Screw System
    Kojima, Atsushi
    Aihara, Takato
    Urushibara, Makoto
    Hatakeyama, Kenji
    Sodeyama, Tomonori
    GLOBAL SPINE JOURNAL, 2023, 13 (04) : 970 - 976
  • [28] The Role of Minimally Invasive Percutaneous Pedicle Screw Fixation for the Management of Spinal Metastatic Disease
    Tannoury, Chadi
    Beeram, Indeevar
    Singh, Varun
    Saade, Aziz
    Bhale, Rahul
    Tannoury, Tony
    WORLD NEUROSURGERY, 2022, 159 : E453 - E459
  • [29] Efficacies of minimally invasive percutaneous pedicle screw fixation versus open pedicle screw fixation on the treatment of type A vertebral fractures at the thoracolumbar junction
    Xu, Siqi
    Qin, Jie
    Feng, Yani
    Ouyang, Pengrong
    Wang, Rui
    Li, Jing
    He, Xijing
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2020, 13 (11): : 9107 - 9115
  • [30] Percutaneous Placement of Pedicle Screws in the Lumbar Spine Using a Bone Mounted Miniature Robotic System First Experiences and Accuracy of Screw Placement Point of View
    Phillips, Frank M.
    SPINE, 2009, 34 (04) : 399 - 399