Accuracy of Implant Positioning in Total Hip Arthroplasty via a Supine Direct Anterior Approach Using Fluoroscopy

被引:0
|
作者
Kanno, Keijiro [1 ]
Hagiwara, Shigeo [1 ]
Shiko, Yuki [2 ]
Kawarai, Yuya [1 ]
Nakamura, Junichi [1 ]
Ohtori, Seiji [1 ]
机构
[1] Chiba Univ, Grad Sch Med, Dept Orthopaed Surg, 1-8-1 Inohana,Chuo Ku, Chiba 2608670, Japan
[2] Chiba Univ Hosp, Clin Res Ctr, Biostat Sect, 1-8-1 Inohana,Chuo Ku, Chiba 2608670, Japan
关键词
direct anterior approach; implant position; propensity score matching; total hip arthroplasty; ACETABULAR COMPONENT ORIENTATION; DISLOCATION; POSTERIOR; PLACEMENT; ALIGNMENT; SURGERY;
D O I
10.1155/aort/8892577
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Adequate implantation is important to avoid complications following total hip arthroplasty (THA). This study aimed to evaluate the accuracy and precision of implant placement in the direct anterior approach (DAA) using fluoroscopy in comparison with the anterolateral approach in lateral decubitus position (OCM) using a single implant.Methods: We retrospectively compared propensity score-matched THAs in DAA with fluoroscopy and in OCM. The achievement ratio of the Lewinnek cup safe zone, absolute difference in alignment, and positioning from preoperative planning was evaluated and compared between each approach.Results: 33 patients in both groups were eligible for this study. Significantly more cups were inside the safe zone in the DAA group than in the OCM group (33/33 vs. 25/33, p = 0.0048). No significant differences were found between the DAA group and OCM group regarding the discrepancy from the target cup inclination, anteversion, and three-dimensional positioning. No significant difference was noted in stem alignment; however, the equality of coronal alignment variances was smaller in the DAA group (p = 0.0047). No significant differences were found in the clinical score and complication rate.Conclusion: The DAA using fluoroscopy may provide more accuracy for cup placement and precision for stem placement than OCM.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Direct Anterior Approach Total Hip Arthroplasty Revisited
    Flevas, Dimitrios A.
    Tsantes, Andreas G.
    Mavrogenis, Andreas F.
    JBJS REVIEWS, 2020, 8 (04)
  • [22] Complications of the Direct Anterior Approach for Total Hip Arthroplasty
    Barton, Cefin
    Kim, Paul R.
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2009, 40 (03) : 371 - +
  • [23] Direct anterior approach for revision total hip arthroplasty
    Manrique, Jorge
    Chen, Antonia F.
    Heller, Snir
    Hozack, William J.
    ANNALS OF TRANSLATIONAL MEDICINE, 2014, 2 (10)
  • [24] Component placement accuracy of two digital intraoperative fluoroscopy supplementation systems in direct anterior total hip arthroplasty
    Tyler Thorne
    Scott Nishioka
    Samantha Andrews
    Kristin Mathews
    Cass Nakasone
    Archives of Orthopaedic and Trauma Surgery, 2022, 142 : 1283 - 1288
  • [25] Component placement accuracy of two digital intraoperative fluoroscopy supplementation systems in direct anterior total hip arthroplasty
    Thorne, Tyler
    Nishioka, Scott
    Andrews, Samantha
    Mathews, Kristin
    Nakasone, Cass
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2022, 142 (06) : 1283 - 1288
  • [26] Fluoroscopy-guided direct anterior approach total hip arthroplasty provides more accurate component positions in the supine position than in the lateral position
    Chen, Penglei
    Liu, Wangxin
    Wu, Cong
    Ruan, Pengfei
    Zeng, Jicheng
    Ji, Weifeng
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [27] Fluoroscopy-guided direct anterior approach total hip arthroplasty provides more accurate component positions in the supine position than in the lateral position
    Penglei Chen
    Wangxin Liu
    Cong Wu
    Pengfei Ruan
    Jicheng Zeng
    Weifeng Ji
    BMC Musculoskeletal Disorders, 24
  • [28] Total hip replacement performed via a direct anterior approach: A comparison of the lateral and supine position
    Rogers, Gareth
    Hoggett, Lee
    Bhutta, Aqeel
    Bonshahi, Ardeshir
    JOURNAL OF ORTHOPAEDICS, 2022, 34 : 344 - 348
  • [29] Accuracy of acetabular cup placement during anterolateral supine total hip arthroplasty using intraoperative fluoroscopy: a retrospective study
    Cho, Eiji
    Hisatome, Takashi
    Oda, Shuhei
    Fujimaki, Hirohisa
    Nakanishi, Kazuyoshi
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [30] Accuracy of acetabular cup placement during anterolateral supine total hip arthroplasty using intraoperative fluoroscopy: a retrospective study
    Eiji Cho
    Takashi Hisatome
    Shuhei Oda
    Hirohisa Fujimaki
    Kazuyoshi Nakanishi
    Journal of Orthopaedic Surgery and Research, 17