Accuracy of Implant Positioning in Total Hip Arthroplasty via a Supine Direct Anterior Approach Using Fluoroscopy

被引:0
|
作者
Kanno, Keijiro [1 ]
Hagiwara, Shigeo [1 ]
Shiko, Yuki [2 ]
Kawarai, Yuya [1 ]
Nakamura, Junichi [1 ]
Ohtori, Seiji [1 ]
机构
[1] Chiba Univ, Grad Sch Med, Dept Orthopaed Surg, 1-8-1 Inohana,Chuo Ku, Chiba 2608670, Japan
[2] Chiba Univ Hosp, Clin Res Ctr, Biostat Sect, 1-8-1 Inohana,Chuo Ku, Chiba 2608670, Japan
关键词
direct anterior approach; implant position; propensity score matching; total hip arthroplasty; ACETABULAR COMPONENT ORIENTATION; DISLOCATION; POSTERIOR; PLACEMENT; ALIGNMENT; SURGERY;
D O I
10.1155/aort/8892577
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Adequate implantation is important to avoid complications following total hip arthroplasty (THA). This study aimed to evaluate the accuracy and precision of implant placement in the direct anterior approach (DAA) using fluoroscopy in comparison with the anterolateral approach in lateral decubitus position (OCM) using a single implant.Methods: We retrospectively compared propensity score-matched THAs in DAA with fluoroscopy and in OCM. The achievement ratio of the Lewinnek cup safe zone, absolute difference in alignment, and positioning from preoperative planning was evaluated and compared between each approach.Results: 33 patients in both groups were eligible for this study. Significantly more cups were inside the safe zone in the DAA group than in the OCM group (33/33 vs. 25/33, p = 0.0048). No significant differences were found between the DAA group and OCM group regarding the discrepancy from the target cup inclination, anteversion, and three-dimensional positioning. No significant difference was noted in stem alignment; however, the equality of coronal alignment variances was smaller in the DAA group (p = 0.0047). No significant differences were found in the clinical score and complication rate.Conclusion: The DAA using fluoroscopy may provide more accuracy for cup placement and precision for stem placement than OCM.
引用
收藏
页数:8
相关论文
共 50 条
  • [11] Accuracy of Acetabular Component Positioning Using Computer-assisted Navigation in Direct Anterior Total Hip Arthroplasty
    Bradley, Michael P.
    Benson, Jessica R.
    Muir, Jeffrey M.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (04)
  • [12] Utility of Intraoperative Fluoroscopic Positioning of Total Hip Arthroplasty Components Using a Posterior and Direct Anterior Approach
    Belyea, Christopher M.
    Lansford, Jefferson L.
    Yim, Duke G.
    MILITARY MEDICINE, 2022, 187 (1-2) : E11 - E16
  • [13] Accuracy of Fluoroscopic Guided Acetabular Component Positioning During Direct Anterior Total Hip Arthroplasty
    Slotkin, Eric M.
    Patel, Preetesh D.
    Suarez, Juan C.
    JOURNAL OF ARTHROPLASTY, 2015, 30 (09): : 102 - 106
  • [14] Robotic-Arm Assisted Direct Anterior Total Hip Arthroplasty; Improving Implant Accuracy
    Xu, Sheng
    Bernardo, Lawrence Irving Calderon
    Yew, Andy Khye Soon
    Pang, Hee Nee
    SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2021, 38
  • [15] Total Hip Arthroplasty via Lateral Approach in Supine Position
    Wang, Jian
    Shi, Zhan-jun
    ORTHOPAEDIC SURGERY, 2014, 6 (02) : 165 - 167
  • [16] Direct Anterior Approach to Total Hip Arthroplasty Using Computer Navigation
    Kreuzer, Stefan
    Leffers, Kevin
    BULLETIN OF THE HOSPITAL FOR JOINT DISEASES, 2011, 69 : S52 - S55
  • [17] Direct anterior approach for total hip arthroplasty using the fracture table
    Horne P.H.
    Olson S.A.
    Current Reviews in Musculoskeletal Medicine, 2011, 4 (3) : 139 - 145
  • [18] Direct anterior approach for total hip arthroplasty using the "bikini incision"
    Corten, Kristoff
    Holzapfel, Boris Michael
    OPERATIVE ORTHOPADIE UND TRAUMATOLOGIE, 2021, 33 (04): : 318 - 330
  • [19] Accuracy comparison of cup positioning during total hip arthroplasty using Hip Align and AR-Hip in the supine position
    Masahiro Fujita
    Shinya Hayashi
    Yuichi Kuroda
    Naoki Nakano
    Toshihisa Maeda
    Takehiko Matsushita
    Tomoyuki Matsumoto
    Ryosuke Kuroda
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 7229 - 7235
  • [20] Accuracy comparison of cup positioning during total hip arthroplasty using Hip Align and AR-Hip in the supine position
    Fujita, Masahiro
    Hayashi, Shinya
    Kuroda, Yuichi
    Nakano, Naoki
    Maeda, Toshihisa
    Matsushita, Takehiko
    Matsumoto, Tomoyuki
    Kuroda, Ryosuke
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (12) : 7229 - 7235