Contactless and continuous monitoring of respiratory rate in a hospital ward: a clinical validation study

被引:0
|
作者
Toften, Stale [1 ]
Kjellstadli, Jonas T. [1 ]
Kvaerness, Jorn [2 ]
Pedersen, Line [3 ,4 ]
Laugsand, Lars E. [4 ,5 ]
Thu, Ole K. F. [6 ,7 ]
机构
[1] Vitalthings, Dept Res & Data Sci, Trondheim, Norway
[2] God Klin Forskning, Oppdal, Norway
[3] St Olavs Univ Hosp, Dept Pain & Complex Disorders, Trondheim, Norway
[4] Norwegian Univ Sci & Technol NTNU, Fac Med & Hlth Sci, Dept Circulat & Med Imaging, Trondheim, Norway
[5] St Olavs Univ Hosp, Emergency Dept, Trondheim, Norway
[6] Vitalthings AS, Trondheim, Norway
[7] St Olavs Univ Hosp, Dept Anesthesia & Intens Care Med, Trondheim, Norway
关键词
contactless monitoring; continuous monitoring; monitoring; respiratory rate; hospital; clinical deterioration; validation; Vitalthings Guardian M10; ALARM FATIGUE; CARDIAC-ARREST; DETERIORATION; SYSTEMS; IMPACT;
D O I
10.3389/fphys.2024.1502413
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Introduction Continuous monitoring of respiratory rate in hospital wards can provide early detection of clinical deterioration, thereby reducing mortality, reducing transfers to intensive care units, and reducing the hospital length of stay. Despite the advantages of continuous monitoring, manually counting every 1-12 h remains the standard of care in most hospital wards. The objective of this study was to validate continuous respiratory rate measurements from a radar-based contactless patient monitor [Vitalthings Guardian M10 (Vitalthings AS, Norway)] in a hospital ward.Methods An observational study (clinicaltrials.gov: NCT06083272) was conducted at the emergency ward of a university hospital. Adult patients were monitored during rest with Vitalthings Guardian M10 in both a stationary and mobile configuration simultaneously with a reference device [Nox T3s (Nox Medical, Alpharetta, GA, United States)]. The agreement was assessed using Bland-Altman 95% limits of agreement. The sensitivity and specificity of clinical alarms were evaluated using a Clarke Error grid modified for continuous monitoring of respiratory rate. Clinical aspects were further evaluated in terms of trend analysis and examination of gaps between valid measurements.Results 32 patients were monitored for a median duration of 42 min [IQR (range) 35-46 (30-59 min)]. The bias was 0.1 and 0.0 breaths min-1 and the 95% limits of agreement ranged from -1.1 to 1.2 and -1.1 to 1.1 breaths min-1 for the stationary and mobile configuration, respectively. The concordances for trends were 96%. No clinical alarms were missed, and no false alarms or technical alarms were generated. No interval without a valid measurement was longer than 5 min.Conclusion Vitalthings Guardian M10 measured respiratory rate accurately and continuously in resting patients in a hospital ward.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Challenges and prospects of visual contactless physiological monitoring in clinical study
    Bin Huang
    Shen Hu
    Zimeng Liu
    Chun-Liang Lin
    Junfeng Su
    Changchen Zhao
    Li Wang
    Wenjin Wang
    npj Digital Medicine, 6
  • [42] Continuous monitoring of cerebrovascular autoregulation: a validation study
    Lang, EW
    Mehdorn, HM
    Dorsch, NWC
    Czosnyka, M
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2002, 72 (05): : 583 - 586
  • [43] Measurement system based on RBG camera signal for contactless breathing pattern and respiratory rate monitoring
    Massaroni, Carlo
    Schena, Emiliano
    Silvestri, Sergio
    Taffoni, Fabrizio
    Merone, Mario
    2018 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2018, : 953 - 958
  • [44] Contactless Monitoring of Respiratory Rate and Breathing Absence from Head Movements Using an RGB Camera
    Gwak, Migyeong
    Vatanparvar, Korosh
    Zhu, Li
    Kuang, Jilong
    Gao, Alex
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [45] The effectiveness of continuous respiratory rate monitoring in predicting hypoxic and pyrexic events: a retrospective cohort study
    McCartan, Thomas A.
    Worrall, Amy P.
    Conluain, Ruan O.
    Alaya, Fatimah
    Mulvey, Christopher
    MacHale, Elaine
    Brennan, Vincent
    Lombard, Lorna
    Walsh, Joanne
    Murray, Myles
    Costello, Richard W.
    Greene, Garrett
    PHYSIOLOGICAL MEASUREMENT, 2021, 42 (06)
  • [46] Clinical validation of a wearable respiratory rate device: A brief report
    Eisenkraft, Arik
    Goldstein, Nir
    Ben Ishay, Arik
    Fons, Meir
    Tabi, Michael
    Sherman, Anna Danielle
    Merin, Roei
    Nachman, Dean
    CHRONIC RESPIRATORY DISEASE, 2023, 20
  • [47] The Effectiveness of Continuous Respiratory Rate Monitoring in Predicting Hypoxic and Pyrexic Events
    McCartan, T. A.
    Worrall, A. P.
    Conluain, R. O.
    Alaya, F.
    Mulvey, C.
    MacHale, E.
    Brennan, V.
    Lombard, L.
    Walsh, J.
    Murray, M.
    Costello, R. W.
    Greene, G.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2021, 190 (SUPPL 1) : S6 - S6
  • [48] Novel Continuous Respiratory Rate Monitoring Using an Armband Wearable Sensor
    Huang, Nicholas
    Zhou, Menglian
    Bian, Dayi
    Mehta, Pooja
    Shah, Milan
    Rajput, Kuldeep Singh
    Selvaraj, Nandakumar
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 7470 - 7475
  • [49] The optimal duration of continuous respiratory rate monitoring to predict in-hospital mortality within seven days of admission - A pilot study in a low resource setting
    Sikakulya, Franck Katembo
    Nakitende, Immaculate
    Nabiryo, Joan
    Pakdel, Rezvan
    Namuleme, Sylivia
    Lumala, Alfred
    Kellett, John
    RESUSCITATION PLUS, 2024, 20
  • [50] Respiratory rate monitoring in ICU patients and healthy volunteers using electrical impedance tomography: a validation study
    Wisse, J. J.
    Flinsenberg, M. J. W.
    Jonkman, A. H.
    Goos, T. G.
    Gommers, D.
    PHYSIOLOGICAL MEASUREMENT, 2024, 45 (05)