Simultaneous Determination of p-Benzoquinone and Resorcinol at Reduced Graphene Oxide Modified Glassy Carbon Electrode

被引:0
|
作者
Oliveira, Eleilde de S. [1 ,2 ]
Marques, Aldalea L. B. [1 ,2 ]
Alves, Ismael Carlos B. [1 ,2 ]
Marques, Edmar P. [1 ,2 ]
dos Santos, Jose Ribamar N. [1 ,2 ]
Sawczuk, Raquel B. dos S. [1 ,2 ]
de Azevedo, Lorena C. Martiniano [1 ,2 ]
Sousa, Janyeid Karla Castro [1 ,2 ]
机构
[1] Fed Univ Maranhao UFMA, Nucl Studies Petr & Energy NEPE, LPQA, Sao Luis, MA, Brazil
[2] Fed Univ Maranhao UFMA, Dept Chem Technol, LAPQAP, Sao Luis, MA, Brazil
来源
关键词
Benzene derivatives; Environmental samples; Reduced graphene oxide; Electrochemical determination; Voltammetry; ELECTROCHEMICAL DETERMINATION; BTEX COMPOUNDS; HYDROQUINONE; CATECHOL; BEHAVIOR; BENZENE; COMPOSITE;
D O I
10.22034/abec.2024.717549
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In this work we report the development of an electrochemical sensor based on a modified glassy carbon electrode (GCE) modified with reduced graphene oxide (rGO) for simultaneous determination of p-benzoquinone (BQ) and resorcinol (RS) in soil and water samples of gas stations, using the electrochemical techniques of cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and square wave voltammetry (SWV). The sensor modification was carried out by drop casting, a 10 mu L aliquot of the rGO suspension was dropped onto the surface of the GCE. The sensor showed a linear response for both analytes through SWV from 20 mu M up to 100 mu M. Good results of sensitivity, limit of detection (LOD), and quantification (LOQ) were obtained for BQ (0.03 mu A mu M-1, 0.37 mu M,( )and 1.23 mu M) and RS (0.07 mu A mu M-1, 0.81 mu M,( )and 2.71 mu M), respectively. The method was tested in environmental samples (soil and water) through spike and recovery procedure (recovery > 99%), with precision (RSD) of 0.10% (BQ) and 0.36% (RS).
引用
收藏
页码:910 / 927
页数:18
相关论文
共 50 条
  • [31] Determination of doxorubicin by reduced graphene oxide/gold/polypyrrole modified glassy carbon electrode: A new preparation strategy
    Behravan, Maryam
    Aghaie, Hossein
    Giahi, Masoud
    Maleknia, Laleh
    DIAMOND AND RELATED MATERIALS, 2021, 117 (117)
  • [32] Electrochemical determination of dopamine using a glassy carbon electrode modified with TiN-reduced graphene oxide nanocomposite
    Haldorai, Yuvaraj
    Vilian, A. T. Ezhil
    Rethinasabapathy, Muruganantham
    Huh, Yun Suk
    Han, Young-Kyu
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 247 : 61 - 69
  • [33] Electrochemical Determination of Dopamine by a Reduced Graphene Oxide-Gold Nanoparticle-Modified Glassy Carbon Electrode
    Chen, Ting
    Tang, Lina
    Yang, Fan
    Zhao, Qiang
    Jin, Xin
    Ning, Yong
    Zhang, Guo-Jun
    ANALYTICAL LETTERS, 2016, 49 (14) : 2223 - 2233
  • [34] Determination of Imidacloprid Based on the Development of a Glassy Carbon Electrode Modified with Reduced Graphene Oxide and Manganese (II) Phthalocyanine
    Paula, Santos Anna
    Elisa Ferreira, Oliveira Ana
    Cesar, Pereira Arnaldo
    ELECTROANALYSIS, 2020, 32 (01) : 86 - 94
  • [35] Electrochemical deposition of gold nanoparticles on reduced graphene oxide modified glassy carbon electrode for simultaneous determination of levodopa, uric acid and folic acid
    Benvidi, Ali
    Dehghani-Firouzabadi, Afsaneh
    Mazloum-Ardakani, Mohammad
    Mirjalili, Bi-Bi Fatemeh
    Zare, Reza
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 736 : 22 - 29
  • [36] Electrochemical sensing of phenacetin on electrochemically reduced graphene oxide modified glassy carbon electrode
    Meng, Xiao-Tong
    Zhu, De-Jing
    Jiang, Yu-Hang
    Cao, Yue
    Si, Wei-Meng
    Cao, Jun
    Li, Qiu-Hong
    Li, Jiao
    Lei, Wu
    NEW CARBON MATERIALS, 2022, 37 (04) : 764 - 771
  • [37] Electrochemical detection of pyrosine with electrochemically reduced graphene oxide modified glassy carbon electrode
    Yong Kong
    Xiaolin Ren
    Zongli Huo
    Guoxin Wang
    Yongxin Tao
    Chao Yao
    European Food Research and Technology, 2013, 236 : 955 - 961
  • [38] Electrochemical detection of selenium using glassy carbon electrode modified with reduced graphene oxide
    Idris, Azeez O.
    Mabuba, Nonhlangabezo
    Nkosi, Duduzile
    Maxakato, Nobanathi
    Arotiba, Omotayo A.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2017, 97 (06) : 534 - 547
  • [39] Direct Electrochemistry of Eugenol at a Glassy Carbon Electrode Modified with Electrochemically Reduced Graphene Oxide
    Wang, Shijie
    Zhang, Ting
    Wang, Zhe
    Wang, Dong
    Wang, Zhao
    Sun, Mojie
    Song, Xiaochen
    Liu, Hong
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2019, 14 (04): : 3618 - 3627
  • [40] Electrochemical detection of pyrosine with electrochemically reduced graphene oxide modified glassy carbon electrode
    Kong, Yong
    Ren, Xiaolin
    Huo, Zongli
    Wang, Guoxin
    Tao, Yongxin
    Yao, Chao
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2013, 236 (06) : 955 - 961