Simultaneous Determination of p-Benzoquinone and Resorcinol at Reduced Graphene Oxide Modified Glassy Carbon Electrode

被引:0
|
作者
Oliveira, Eleilde de S. [1 ,2 ]
Marques, Aldalea L. B. [1 ,2 ]
Alves, Ismael Carlos B. [1 ,2 ]
Marques, Edmar P. [1 ,2 ]
dos Santos, Jose Ribamar N. [1 ,2 ]
Sawczuk, Raquel B. dos S. [1 ,2 ]
de Azevedo, Lorena C. Martiniano [1 ,2 ]
Sousa, Janyeid Karla Castro [1 ,2 ]
机构
[1] Fed Univ Maranhao UFMA, Nucl Studies Petr & Energy NEPE, LPQA, Sao Luis, MA, Brazil
[2] Fed Univ Maranhao UFMA, Dept Chem Technol, LAPQAP, Sao Luis, MA, Brazil
来源
关键词
Benzene derivatives; Environmental samples; Reduced graphene oxide; Electrochemical determination; Voltammetry; ELECTROCHEMICAL DETERMINATION; BTEX COMPOUNDS; HYDROQUINONE; CATECHOL; BEHAVIOR; BENZENE; COMPOSITE;
D O I
10.22034/abec.2024.717549
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In this work we report the development of an electrochemical sensor based on a modified glassy carbon electrode (GCE) modified with reduced graphene oxide (rGO) for simultaneous determination of p-benzoquinone (BQ) and resorcinol (RS) in soil and water samples of gas stations, using the electrochemical techniques of cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and square wave voltammetry (SWV). The sensor modification was carried out by drop casting, a 10 mu L aliquot of the rGO suspension was dropped onto the surface of the GCE. The sensor showed a linear response for both analytes through SWV from 20 mu M up to 100 mu M. Good results of sensitivity, limit of detection (LOD), and quantification (LOQ) were obtained for BQ (0.03 mu A mu M-1, 0.37 mu M,( )and 1.23 mu M) and RS (0.07 mu A mu M-1, 0.81 mu M,( )and 2.71 mu M), respectively. The method was tested in environmental samples (soil and water) through spike and recovery procedure (recovery > 99%), with precision (RSD) of 0.10% (BQ) and 0.36% (RS).
引用
收藏
页码:910 / 927
页数:18
相关论文
共 50 条
  • [11] Modified Glassy Carbon Electrode with Silver Nanoparticles/Polyaniline/Reduced Graphene Oxide Nanocomposite for the Simultaneous Determination of Biocompounds in Biological Fluids
    Ghanbari, Kh
    Moloudi, M.
    Bonyadi, S.
    JOURNAL OF ELECTROCHEMICAL SCIENCE AND TECHNOLOGY, 2019, 10 (04) : 361 - 372
  • [12] Simultaneous Determination of Theophylline and Caffeine Using Poly(L-phenylalanine)-Reduced Graphene Oxide Modified Glassy Carbon Electrode
    Zhang, Lin
    Wang, Ting
    Fan, Xinxia
    Deng, Dongmei
    Li, Yuanyuan
    Yan, Xiaoxia
    Luo, Liqiang
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (04): : 1 - 11
  • [13] Simultaneous determination of dihydroxybenzene isomers based on graphene-graphene oxide nanocomposite modified glassy carbon electrode
    Zhou, Xibin
    He, Zhifang
    Lian, Qianwen
    Li, Zhao
    Jiang, Huan
    Lu, Xiaoquan
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 193 : 198 - 204
  • [14] A glassy carbon electrode modified with cerium phosphate nanotubes for the simultaneous determination of hydroquinone, catechol and resorcinol
    Li, Zhen
    Yue, Yuhua
    Hao, Yanjun
    Feng, Shun
    Zhou, Xianli
    MICROCHIMICA ACTA, 2018, 185 (04)
  • [15] Simultaneous Determination of Acetaminophen and Caffeine Based on Graphene Oxide/Cerium Hexacyanoferrate Modified Glassy Carbon Electrode
    Lu Xian-Chun
    Huang Ke-Jing
    Wu Zhi-Wei
    Huang Shu-Fang
    Xu Chun-Xuan
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 40 (03) : 452 - 456
  • [16] Simultaneous Determination of Catechol, Hydroquinone, and Resorcinol on CTAB Functionalized Graphene Oxide/Multiwalled Carbon Nanotube Modified Electrode
    Yang, Yu Jun
    Li, Weikun
    FULLERENES NANOTUBES AND CARBON NANOSTRUCTURES, 2015, 23 (05) : 410 - 417
  • [17] A glassy carbon electrode modified with cerium phosphate nanotubes for the simultaneous determination of hydroquinone, catechol and resorcinol
    Zhen Li
    Yuhua Yue
    Yanjun Hao
    Shun Feng
    Xianli Zhou
    Microchimica Acta, 2018, 185
  • [18] Polyfurfural-Electrochemically Reduced Graphene Oxide Modified Glassy Carbon Electrode for the Direct Determination of Nitrofurazone
    Ye, Fang
    Huang, Jianzhi
    Xu, Yongqun
    Zeng, Qiang
    Nan, Junmin
    Wang, Lishi
    ANALYTICAL LETTERS, 2018, 51 (05) : 728 - 741
  • [19] Electrochemical Behavior and Determination of Matrine by the Reduced Graphene Oxide-Nafion Modified Glassy Carbon Electrode
    Zhang, Hongjiao
    Xiong, Huabin
    Gao, Yuntao
    Wang, Zhengwei
    Li, Xiaofen
    Ma, Xiaoyan
    Yang, Hongqiao
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (08): : 6348 - 6358
  • [20] Copper nanoparticles and reduced graphene oxide modified a glassy carbon electrode for the determination of glyphosate in water samples
    Setznagl, Sarah
    Cesarino, Ivana
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2022, 102 (01) : 293 - 305