Optimal filling ratios and thermal performance of a two-phase closed thermosyphon pile in frozen soil under warming conditions

被引:0
|
作者
Abweny, Mohammad A. [1 ]
Abdel-Jawad, Ammar [1 ]
Xiao, Suguang [1 ]
机构
[1] Clarkson Univ, Dept Civil & Environm Engn, Potsdam, NY 13699 USA
关键词
Filling ratio; Two-phase closed thermosyphon; Climate change; Permafrost; Cooling capacity; THAW SETTLEMENT; PERMAFROST;
D O I
10.1016/j.applthermaleng.2025.125441
中图分类号
O414.1 [热力学];
学科分类号
摘要
Two-phase closed thermosyphon (TPCT) piles have been employed since the 1960s to stabilize ground temperatures in permafrost regions, preserving the structural integrity of foundations. TPCT piles utilize phase change processes of working fluids, such as CO2 or ammonia, to extract heat from the permafrost and lower its temperature during winter. One important factor influencing the performance of TPCT piles is the filling ratio of the working fluid, which remains underexplored in existing literature. This study aims to fill this gap by investigating the thermal performance of TPCT piles in frozen sandy soil through experiments conducted in a cold room, using a soil box measuring 1.38 m by 0.9 m by 1.22 m. Two model piles, each with a diameter of 63.5 mm and a length of 810 mm, were installed in the soil box. One pile was a CO2-charged TPCT, leveraging the thermosyphon principle, while the other was a conventional uncharged pile for baseline comparison. The filling ratio of the TPCT pile varied from 10 % to 60 % to assess its impact on thermal performance. Five temperature cycles were applied, with the final two cycles incorporating a gradual warming rate of 2 degrees C per cycle to simulate climate change. Results indicated that a filling ratio between 30 % and 50 % optimized thermal performance. Furthermore, the cooling capacity of TPCT piles was reduced by 11.9 % with every 1 degrees C increase in air temperature during the cooling period, providing valuable insights for designing TPCT piles in permafrost regions under warming conditions.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Thermal performance enhancement and optimization of two-phase closed thermosyphon with graphene-nanoplatelets coatings
    Advanced Engineering Platform, School of Engineering, Monash University, Bandar Sunway
    47500, Malaysia
    不详
    230027, China
    Energy Convers. Manage.,
  • [42] Investigation of low Global Warming Potential working fluids for a closed two-phase thermosyphon
    MacGregor, Robert W.
    Kew, Peter A.
    Reay, David A.
    APPLIED THERMAL ENGINEERING, 2013, 51 (1-2) : 917 - 925
  • [43] Thermal extraction from a low-temperature stage of coal pile spontaneous combustion by two-phase closed thermosyphon
    Xiao, Yang
    Zhong, Kai-Qi
    Tian, Jia-Yao
    Yin, Lan
    Tian, Yuan
    Shu, Chi-Min
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2021, 144 (02) : 587 - 597
  • [44] The experimental investigation on thermal performance of a flat two-phase thermosyphon
    Zhang, Ming
    Liu, Zhongliang
    Ma, Guoyuan
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2008, 47 (09) : 1195 - 1203
  • [45] Thermal performance of a two-phase thermosyphon energy storage system
    Lin, MC
    Chun, LJ
    Lee, WS
    Chen, SL
    SOLAR ENERGY, 2003, 75 (04) : 295 - 306
  • [46] Thermal extraction from a low-temperature stage of coal pile spontaneous combustion by two-phase closed thermosyphon
    Yang Xiao
    Kai-Qi Zhong
    Jia-Yao Tian
    Lan Yin
    Yuan Tian
    Chi-Min Shu
    Journal of Thermal Analysis and Calorimetry, 2021, 144 : 587 - 597
  • [47] Numerical simulation on the heat transfer characteristics of two-phase loop thermosyphon with high filling ratios
    Wang, Kuiming
    Hu, Chengzhi
    Jiang, Bo
    Hu, Xianfeng
    Tang, Dawei
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2022, 184
  • [48] Experimental study on the thermal performance of a novel two-phase loop thermosyphon under low-heat-flux conditions
    Wang, Lin
    Zhong, Wei
    Min, Wandong
    Wang, Zijin
    Cao, Xiaoling
    APPLIED THERMAL ENGINEERING, 2024, 236
  • [49] Evaluation of the thermal performance of a solar water heating thermosyphon versus a two-phase closed thermosyphon using different working fluids
    Ordaz-Flores, A.
    Garcia-Valladares, O.
    Gomez, V. H.
    PROCEEDINGS OF ISES SOLAR WORLD CONGRESS 2007: SOLAR ENERGY AND HUMAN SETTLEMENT, VOLS I-V, 2007, : 789 - 793
  • [50] Thermal performance of sub-atmospheric two-phase loop thermosyphon at pitching and rolling conditions
    Chang, Shyy Woei
    Huang, Bo Jyun
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 77 : 745 - 764