Optimal filling ratios and thermal performance of a two-phase closed thermosyphon pile in frozen soil under warming conditions

被引:0
|
作者
Abweny, Mohammad A. [1 ]
Abdel-Jawad, Ammar [1 ]
Xiao, Suguang [1 ]
机构
[1] Clarkson Univ, Dept Civil & Environm Engn, Potsdam, NY 13699 USA
关键词
Filling ratio; Two-phase closed thermosyphon; Climate change; Permafrost; Cooling capacity; THAW SETTLEMENT; PERMAFROST;
D O I
10.1016/j.applthermaleng.2025.125441
中图分类号
O414.1 [热力学];
学科分类号
摘要
Two-phase closed thermosyphon (TPCT) piles have been employed since the 1960s to stabilize ground temperatures in permafrost regions, preserving the structural integrity of foundations. TPCT piles utilize phase change processes of working fluids, such as CO2 or ammonia, to extract heat from the permafrost and lower its temperature during winter. One important factor influencing the performance of TPCT piles is the filling ratio of the working fluid, which remains underexplored in existing literature. This study aims to fill this gap by investigating the thermal performance of TPCT piles in frozen sandy soil through experiments conducted in a cold room, using a soil box measuring 1.38 m by 0.9 m by 1.22 m. Two model piles, each with a diameter of 63.5 mm and a length of 810 mm, were installed in the soil box. One pile was a CO2-charged TPCT, leveraging the thermosyphon principle, while the other was a conventional uncharged pile for baseline comparison. The filling ratio of the TPCT pile varied from 10 % to 60 % to assess its impact on thermal performance. Five temperature cycles were applied, with the final two cycles incorporating a gradual warming rate of 2 degrees C per cycle to simulate climate change. Results indicated that a filling ratio between 30 % and 50 % optimized thermal performance. Furthermore, the cooling capacity of TPCT piles was reduced by 11.9 % with every 1 degrees C increase in air temperature during the cooling period, providing valuable insights for designing TPCT piles in permafrost regions under warming conditions.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] The interface effect of carbon nanotube suspension on the thermal performance of a two-phase closed thermosyphon
    Xue, H. S.
    Fan, J. R.
    Hu, Y. C.
    Hong, R. H.
    Cen, K. F.
    JOURNAL OF APPLIED PHYSICS, 2006, 100 (10)
  • [22] Effects of hydrophobic and superhydrophobic coatings of a condenser on the thermal performance of a two-phase closed thermosyphon
    Kim, Yeonghwan
    Kim, Jin Sub
    Shin, Dong Hwan
    Seo, Jin Hyeuk
    You, Seung M.
    Lee, Jungho
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 144
  • [23] Upgrading of the thermal performance of two-phase closed thermosyphon (TPCT) using fusel oil
    Sozen, Adnan
    Menlik, Tayfun
    Guru, Metin
    Aktas, Mustafa
    HEAT AND MASS TRANSFER, 2017, 53 (01) : 141 - 149
  • [24] Numerical investigations on the thermal performance of two-phase closed thermosyphon with extended condenser surface
    Zhao Liu
    Jin Zhao
    Chao Wang
    Yangjun Qin
    Yanbiao Wang
    Chang Liu
    Heat and Mass Transfer, 2023, 59 : 377 - 392
  • [25] Effect of sintered microporous coating at the evaporator on the thermal performance of a two-phase closed thermosyphon
    Kim, Yeonghwan
    Shin, Dong Hwan
    Kim, Jin Sub
    You, Seung M.
    Lee, Jungho
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 131 : 1064 - 1074
  • [26] Experimental and computational investigation of thermal performance and fluid flow in two-phase closed thermosyphon
    Cho, Sehyeon
    Kong, Daeyoung
    Geum, Gyohoon
    Kang, Sukkyung
    Seo, Jin Hyeuk
    Kim, Jun Soo
    Lee, Seong Hyuk
    Lee, Jungho
    Lee, Hyoungsoon
    APPLIED THERMAL ENGINEERING, 2023, 235
  • [27] The interface effect of carbon nanotube suspension on the thermal performance of a two-phase closed thermosyphon
    Xue, H.S.
    Fan, J.R.
    Hu, Y.C.
    Hong, R.H.
    Cen, K.F.
    Journal of Applied Physics, 2006, 100 (10):
  • [28] Performance enhancement of a two-phase closed thermosyphon with a vortex generator
    Tarokh, Ali
    Bliss, Connor
    Hemmati, Arman
    APPLIED THERMAL ENGINEERING, 2021, 182
  • [29] Climate warming is likely to weaken the performance of two-phase closed thermosyphon on the Qinghai-Tibet Plateau
    Jiang, Guan-Li
    Fu, Zi-Teng
    Men, Xin-Yu
    Zhao, Hong -Ting
    Gao, Si-Ru
    Liu, Yong-Zhi
    Wu, Qing-Bai
    ADVANCES IN CLIMATE CHANGE RESEARCH, 2024, 15 (01): : 90 - 100
  • [30] Thermal performance of reciprocating two-phase thermosyphon with nozzle
    Chang, Shyy Woei
    Yu, Kuo-Ching