Quantitative study on magnetic flux leakage internal detection signal of defects on the outer wall of bimetal composite pipes

被引:0
|
作者
He, Tengjiao [1 ]
Zhong, Hanyu [1 ]
Liao, Kexi [1 ]
Liao, Jiancheng [1 ]
Zhao, Shuai [2 ]
He, Guoxi [1 ]
Zhang, Jiezhen [3 ]
机构
[1] Southwest Petr Univ, Petr Engn Sch, Chengdu 610500, Peoples R China
[2] PetroChina Southwest Oil & Gas Field Co, Safety Environm & Technol Supervis Res Inst, Chengdu 610041, Peoples R China
[3] PetroChina Xinjiang Oilfield Co, Karamay 834003, Xinjiang, Peoples R China
关键词
Bimetal composite pipe; MFL; Multi-layer media; Magnetic dipole; Non-magnetic saturation; PSO-LSTM;
D O I
10.1016/j.ijpvp.2025.105438
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Bimetal composite pipes are widely used in oil and gas gathering pipelines due to their exceptional anti-corrosion and high-pressure resistance properties. However, the magnetic flux leakage (MFL) internal detection device for single-layer pipes is unsuitable for the bimetal composite pipe. It is difficult to detect the location and size of pipe defects in the outer layer. To solve the problem of poor detection performance for the bimetal composite pipe, this paper conducted a series of studies. Firstly, in this paper, the multi-layer media magnetic dipole model for bimetal composite pipes is established. Then, the influence of the thickness and permeability of the inner layer on the MFL signal of the outer wall defects is quantitatively studied. What's more, a MFL detection simulation model for bimetal composite pipes is established, and the detection rate of defects on the outer wall of bimetal composite pipes is improved by optimizing the design of the magnetization device. Finally, a defect size inversion method in the outer layer of bimetal composite pipes is proposed, which is validated by an indoor experimental test. The results indicate that compared to the case with the inner layer, the amplitude of axial and radial MFL signals raise by 74 % and 76 % respectively in the absence of an inner layer pipeline. The amplitude of the MFL signal of the outer wall defect decreases exponentially as the thickness and relative magnetic permeability of the inner layer increase. After optimizing the magnetization device, the magnetic induction intensity of the outer layer is increased by 29 %, and the detection rate of defects is increased by 37 %. The maximum error of the defect size inversion model is 6.4 %, which meets the requirements of engineering applications.
引用
收藏
页数:20
相关论文
共 50 条
  • [41] A Simplified Lift-Off Correction for Three Components of the Magnetic Flux Leakage Signal for Defect Detection
    Peng, Lisha
    Huang, Songling
    Wang, Shen
    Zhao, Wei
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [42] A novel sensor based on the composite mechanism of magnetic flux leakage and magnetic field disturbance for comprehensive inspection of defects with varying angles and widths
    Shen, Yang
    Wang, Yujue
    Wu, Bin
    Li, Peng
    Han, Zhenhua
    Zhang, Changhu
    Liu, Xiucheng
    NDT & E INTERNATIONAL, 2024, 145
  • [43] Quantitative Evaluation of Deformation in High-Speed Magnetic Flux Leakage Signals for Weld Defects in Oil and Gas Pipelines
    Ren, Lemei
    Liu, Wenlong
    Zhu, Bo
    Tian, Guansan
    Lu, Hui
    Yan, Linkai
    PROCESSES, 2024, 12 (11)
  • [44] A Novel Cascaded Deep Learning Model for the Detection and Quantification of Defects in Pipelines via Magnetic Flux Leakage Signals
    Yuksel, Veysel
    Tetik, Yusuf Engin
    Basturk, Mahmut Omer
    Recepoglu, Onur
    Gokce, Kursad
    Cimen, Mehmet Ali
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [45] Study on the Impact of Pole Spacing on Magnetic Flux Leakage Detection under Oversaturated Magnetization
    Liu, Wenlong
    Ren, Lemei
    Tian, Guansan
    SENSORS, 2024, 24 (16)
  • [46] Study on Corroded Detection of Bridge Prestressed Reinforcement Based on the Magnetic Flux Leakage method
    Zhao, Jun
    Niu, Ditao
    VIBRATION, STRUCTURAL ENGINEERING AND MEASUREMENT I, PTS 1-3, 2012, 105-107 : 1241 - 1244
  • [47] Quantitative study on internal detection signal of weak magnetic stress in oil and gas pipelines based on force-magnetic noncoaxial effect
    Liu, Bin
    Sun, Jiayu
    He, Luyao
    Geng, Hao
    Yang, Lijian
    MEASUREMENT, 2023, 215
  • [48] Influence of curvature radius on the axial crack signal of the magnetic flux leakage detection for tapered roller bearing rings
    Yang, Yun
    Peng, Guang
    Qiu, Shaoxiong
    Chen, Cuili
    Liang, Zhenyu
    FRONTIERS IN PHYSICS, 2023, 10
  • [49] Quantitative Detection of Wire Rope Based on Three-Dimensional Magnetic Flux Leakage Color Imaging Technology
    Zhang, Juwei
    Peng, Fuchang
    Chen, Jinbao
    IEEE ACCESS, 2020, 8 : 104165 - 104174
  • [50] Quantitative corrosion detection of reinforced concrete based on self-magnetic flux leakage and rust spot area
    Chen, Lin
    Liu, Xianlin
    Lin, Yunfei
    Xia, Junfeng
    Zhao, Siyu
    Zhang, Senhua
    ENGINEERING RESEARCH EXPRESS, 2022, 4 (03):