Quantitative study on magnetic flux leakage internal detection signal of defects on the outer wall of bimetal composite pipes

被引:0
|
作者
He, Tengjiao [1 ]
Zhong, Hanyu [1 ]
Liao, Kexi [1 ]
Liao, Jiancheng [1 ]
Zhao, Shuai [2 ]
He, Guoxi [1 ]
Zhang, Jiezhen [3 ]
机构
[1] Southwest Petr Univ, Petr Engn Sch, Chengdu 610500, Peoples R China
[2] PetroChina Southwest Oil & Gas Field Co, Safety Environm & Technol Supervis Res Inst, Chengdu 610041, Peoples R China
[3] PetroChina Xinjiang Oilfield Co, Karamay 834003, Xinjiang, Peoples R China
关键词
Bimetal composite pipe; MFL; Multi-layer media; Magnetic dipole; Non-magnetic saturation; PSO-LSTM;
D O I
10.1016/j.ijpvp.2025.105438
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Bimetal composite pipes are widely used in oil and gas gathering pipelines due to their exceptional anti-corrosion and high-pressure resistance properties. However, the magnetic flux leakage (MFL) internal detection device for single-layer pipes is unsuitable for the bimetal composite pipe. It is difficult to detect the location and size of pipe defects in the outer layer. To solve the problem of poor detection performance for the bimetal composite pipe, this paper conducted a series of studies. Firstly, in this paper, the multi-layer media magnetic dipole model for bimetal composite pipes is established. Then, the influence of the thickness and permeability of the inner layer on the MFL signal of the outer wall defects is quantitatively studied. What's more, a MFL detection simulation model for bimetal composite pipes is established, and the detection rate of defects on the outer wall of bimetal composite pipes is improved by optimizing the design of the magnetization device. Finally, a defect size inversion method in the outer layer of bimetal composite pipes is proposed, which is validated by an indoor experimental test. The results indicate that compared to the case with the inner layer, the amplitude of axial and radial MFL signals raise by 74 % and 76 % respectively in the absence of an inner layer pipeline. The amplitude of the MFL signal of the outer wall defect decreases exponentially as the thickness and relative magnetic permeability of the inner layer increase. After optimizing the magnetization device, the magnetic induction intensity of the outer layer is increased by 29 %, and the detection rate of defects is increased by 37 %. The maximum error of the defect size inversion model is 6.4 %, which meets the requirements of engineering applications.
引用
收藏
页数:20
相关论文
共 50 条
  • [31] Study of signal mechanism based on combining magnetic flux leakage and eddy current testing
    School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
    不详
    不详
    Jixie Gongcheng Xuebao, 2009, 7 (233-237):
  • [32] Quantitative Study on Corrosion of Steel Strands Based on Self-Magnetic Flux Leakage
    Xia, Runchuan
    Zhou, Jianting
    Zhang, Hong
    Liao, Leng
    Zhao, Ruiqiang
    Zhang, Zeyu
    SENSORS, 2018, 18 (05)
  • [33] Numerical analysis and experimental study of magnetic flux leakage detection for the weld defect
    Wei, Cui
    Peng-xiao, Zhao
    BioTechnology: An Indian Journal, 2014, 10 (08) : 2923 - 2931
  • [34] Multifrequency AC Magnetic Flux Leakage Testing for the Detection of Surface and Backside Defects in Thick Steel Plates
    Wang, Gang
    Xiao, Qi
    Gao, Zihao
    Li, Wenhui
    Jia, Liang
    Liang, Ce
    Yu, Xue
    IEEE MAGNETICS LETTERS, 2022, 13
  • [35] Research on Image Detection and Recognition for Defects on the Surface of the Steel Plate Based on Magnetic Flux Leakage Signals
    Wang Ze-song
    2017 29TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2017, : 6139 - 6144
  • [36] Prediction of Depth Defects During Pipeline Magnetic Flux Leakage Detection Based on the AVOA-BPNN
    Xu, Lushuai
    Dong, Shaohua
    Peng, Donghua
    Wei, Haotian
    Ma, Yundong
    PROCEEDINGS OF ASME 2023 PRESSURE VESSELS & PIPING CONFERENCE, PVP2023, VOL 7, 2023,
  • [37] Theoretical study on the characteristics of self-magnetic flux leakage signals from pipeline defects
    Li, Changjun
    Li, Zhongji
    Jia, Wenlong
    INSIGHT, 2019, 61 (09) : 536 - 541
  • [38] STUDY ON LOW FREQUENCY AC EXCITATION MAGNETIC FLUX LEAKAGE TESTING FOR DEFECTS WITH DIFFERENT DEPTHS
    Lu, Xinyuan
    Li, Guanghai
    Chen, Liangchao
    Chang, Yu
    Zhang, Xiaozhu
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE, 2018, VOL 5, 2019,
  • [39] Study of Defects in the Petrochemical Storage Tank Floor using the Magnetic Flux Leakage (MFL) Technique
    Durai, Mathivanan
    Lin, Zi-Qi
    Lan, Chou-Wei
    Chang, Ho
    Peng, Chi-Chuan
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2022, 22 (02) : 807 - 814
  • [40] Study of Defects in the Petrochemical Storage Tank Floor using the Magnetic Flux Leakage (MFL) Technique
    Mathivanan Durai
    Zi-Qi Lin
    Chou-Wei Lan
    Ho Chang
    Chi-Chuan Peng
    Journal of Failure Analysis and Prevention, 2022, 22 : 807 - 814