Quantitative study on magnetic flux leakage internal detection signal of defects on the outer wall of bimetal composite pipes

被引:0
|
作者
He, Tengjiao [1 ]
Zhong, Hanyu [1 ]
Liao, Kexi [1 ]
Liao, Jiancheng [1 ]
Zhao, Shuai [2 ]
He, Guoxi [1 ]
Zhang, Jiezhen [3 ]
机构
[1] Southwest Petr Univ, Petr Engn Sch, Chengdu 610500, Peoples R China
[2] PetroChina Southwest Oil & Gas Field Co, Safety Environm & Technol Supervis Res Inst, Chengdu 610041, Peoples R China
[3] PetroChina Xinjiang Oilfield Co, Karamay 834003, Xinjiang, Peoples R China
关键词
Bimetal composite pipe; MFL; Multi-layer media; Magnetic dipole; Non-magnetic saturation; PSO-LSTM;
D O I
10.1016/j.ijpvp.2025.105438
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Bimetal composite pipes are widely used in oil and gas gathering pipelines due to their exceptional anti-corrosion and high-pressure resistance properties. However, the magnetic flux leakage (MFL) internal detection device for single-layer pipes is unsuitable for the bimetal composite pipe. It is difficult to detect the location and size of pipe defects in the outer layer. To solve the problem of poor detection performance for the bimetal composite pipe, this paper conducted a series of studies. Firstly, in this paper, the multi-layer media magnetic dipole model for bimetal composite pipes is established. Then, the influence of the thickness and permeability of the inner layer on the MFL signal of the outer wall defects is quantitatively studied. What's more, a MFL detection simulation model for bimetal composite pipes is established, and the detection rate of defects on the outer wall of bimetal composite pipes is improved by optimizing the design of the magnetization device. Finally, a defect size inversion method in the outer layer of bimetal composite pipes is proposed, which is validated by an indoor experimental test. The results indicate that compared to the case with the inner layer, the amplitude of axial and radial MFL signals raise by 74 % and 76 % respectively in the absence of an inner layer pipeline. The amplitude of the MFL signal of the outer wall defect decreases exponentially as the thickness and relative magnetic permeability of the inner layer increase. After optimizing the magnetization device, the magnetic induction intensity of the outer layer is increased by 29 %, and the detection rate of defects is increased by 37 %. The maximum error of the defect size inversion model is 6.4 %, which meets the requirements of engineering applications.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Internal and External Defects Discrimination of Pipelines Using Composite Magnetic Flux Leakage Detection
    Long, Yue
    Huang, Songling
    Peng, Lisha
    Wang, Wenzhi
    Wang, Shen
    Zhao, Wei
    2021 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC 2021), 2021,
  • [2] Quantization of magnetic flux leakage internal detection signals for composite defects of gas and oil pipelines
    Liu, Bin
    Wu, Zihan
    Wang, Peng
    He, Luyao
    Yang, Lijian
    Lian, Zheng
    Liu, Tong
    ENERGY REPORTS, 2023, 9 : 5899 - 5914
  • [3] Importance of Magnetizing Field on Magnetic Flux Leakage Signal of Defects
    Hong Quang Pham
    Quang Trung Trinh
    Duy Tuan Doan
    Quang Hung Tran
    IEEE TRANSACTIONS ON MAGNETICS, 2018, 54 (06)
  • [4] Magnetic flux leakage signal analysis of pipe defects and signal characterization extractions
    Wang, TY
    Jiang, Q
    Wen, S
    Shang, ZW
    CONDITION MONITORING 2001, PROCEEDINGS, 2001, : 126 - 133
  • [5] A composite testing method of homologous magnetic flux leakage and motion-induced eddy current for inner and outer defects
    Liang, Ce
    Wang, Gang
    Ma, Hanting
    Xiao, Qi
    Yu, Xue
    MEASUREMENT, 2025, 240
  • [6] NONLINEAR MODEL OF FLAW DETECTION IN STEEL PIPES BY MAGNETIC-FLUX LEAKAGE
    ALTSCHULER, E
    PIGNOTTI, A
    NDT & E INTERNATIONAL, 1995, 28 (01) : 35 - 40
  • [7] A Signal Filtering Method for Magnetic Flux Leakage Detection of Rail Surface Defects Based on Minimum Entropy Deconvolution
    Liu, Jing
    Su, Shoubao
    Guo, Haifeng
    Lu, Yuhua
    Chen, Yuexia
    INTERNATIONAL JOURNAL OF SWARM INTELLIGENCE RESEARCH, 2024, 15 (01)
  • [8] Quantization of pipeline magnetic flux leakage detection signal under load
    Liu T.
    Liu B.
    Feng G.
    Lian Z.
    Yang L.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2022, 43 (01): : 262 - 273
  • [9] Detection of Natural Gas Pipeline Defects using Magnetic Flux Leakage Measurements
    Kandroodi, Mojtaba Rostami
    Araabi, Babak Nadjar
    Ahmadabadi, Majid Nili
    Shirani, Farshad
    Bassiri, Maisam Mansoob
    2013 21ST IRANIAN CONFERENCE ON ELECTRICAL ENGINEERING (ICEE), 2013,
  • [10] Magnetic Flux Leakage Signal Processing in Strip Steel Flaw Area Detection
    Chen, Jiangying
    Chen, Weiting
    Qian, Shijin
    Chen, Delu
    2013 6TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING (CISP), VOLS 1-3, 2013, : 1096 - 1100