Arrhythmia Detection in Atrioventricular, Single-Lead, Floating Atrial Dipole ICD Systems Compared with Conventional Single- and Dual-Chamber Defibrillators

被引:0
|
作者
Gausz, Flora Diana [1 ]
Lena, Kom Nangob Manuela [1 ,2 ]
Gedeon, Paul Emmanuel [1 ,3 ]
Miklos, Marton [1 ]
Benak, Attila [1 ]
Bencsik, Gabor [1 ]
Makai, Attila [1 ]
Kranyak, Dora [1 ]
Gagyi, Rita Beata [1 ]
Pap, Robert [1 ]
Saghy, Laszlo [1 ]
Szili-Torok, Tamas [1 ]
Vamos, Mate [1 ]
机构
[1] Univ Szeged, Cardiol Ctr, Dept Internal Med, Cardiac Electrophysiol Div, H-6725 Szeged, Hungary
[2] Univ Szeged, Dept Oncotherapy, H-6720 Szeged, Hungary
[3] Queen Elizabeth Univ Hosp, Neurosurg, Glasgow G51 4TF, Scotland
关键词
ICD; implantable cardioverter defibrillator; floating atrial sensing dipole; VDD; tachycardia discrimination; atrial arrythmia detection; IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS; RISK; DISCRIMINATION; FIBRILLATION; RATIONALE; SHOCKS;
D O I
10.3390/jcdd11120386
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: An atrioventricular defibrillator system with a floating atrial dipole (VDD ICD) can provide atrial sensing by a single lead. Our aim was to compare the arrhythmia detection efficacy of VDD ICDs with conventional single- (VVI) and dual-chamber (DDD) defibrillators. Methods: Data from consecutive patients undergoing ICD implantation were retrospectively analyzed. The primary endpoint was the incidence of device-detected, new-onset atrial arrhythmias, while secondary endpoints were sensing parameters, complication rates, incidence of appropriate/inappropriate ICD therapy, arrhythmic/heart failure-related hospitalizations, and all-cause mortality. Results: A total of 256 patients (mean age 64 +/- 12 years, male 75%, primary prophylaxis 28%, mean follow-up 3.7 +/- 2.4 years) were included (VVI: 93, VDD: 94, DDD: 69). Atrial arrhythmia episodes were detected more frequently by VDD systems compared to VVI ICDs (aHR 7.087; 95% CI 2.371-21.183; p < 0.001), and at a rate similar to that of DDD ICDs (aHR 1.781; 95% CI 0.737-4.301; p = 0.200). The rate of inappropriate shocks was not different among the three ICD systems. Conclusion: VDD devices revealed an advantage in atrial arrhythmia detection compared to VVI ICDs and were non-inferior to DDD systems. Their main indication may be closer monitoring in high-risk patients with atrial arrhythmias to help therapy optimization and not the improvement of tachycardia discrimination.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Cost-Effectiveness of Single-Chamber Compared with Dual-Chamber and Single-Lead with Atrial Sensing Implantable Cardioverter Defibrillators
    Hutton, David W.
    Harvey, Michael J.
    Thaker, Jay P.
    Freeman, James V.
    CIRCULATION, 2014, 130
  • [2] Rationale and feasibility of the atrioventricular single-lead ICD systems with a floating atrial dipole (DX) in clinical practice
    Vamos, Mate
    Nemeth, Marianna
    Balazs, Tibor
    Zima, Endre
    Duray, Gabor Zoltan
    TRENDS IN CARDIOVASCULAR MEDICINE, 2022, 32 (02) : 84 - 89
  • [3] Arrhythmia Detection in Single- and Dual-Chamber Implantable Cardioverter Defibrillators: The More Leads, the Better?
    Francia, Pietro
    Balla, Cristina
    Uccellini, Arianna
    Cappato, Riccardo
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2009, 20 (09) : 1077 - 1082
  • [4] A NEW DUAL-CHAMBER SINGLE-LEAD SYSTEM
    HIRSCHBERG, J
    EKWALL, C
    STRANDBERG, H
    CARLSTEN, J
    BOWALD, S
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (11): : 1870 - 1872
  • [5] IS LESS MORE? BENEFITS OF A NEW SINGLE-CHAMBER ICD WITH ATRIAL SENSING COMPARED WITH DUAL-CHAMBER ICD
    Maludum, Obiora
    Balderia, Percy
    Nixon, Yolanda
    Sheeron, Bernadette
    Smukler, Jessica
    Joshi, Kamal
    Greenspan, Allan
    Mainigi, Sumeet
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (10) : A326 - A326
  • [6] Neuroendocrine and haemodynamic changes in single-lead atrial pacing and dual-chamber pacing modes
    Zhang, Ying-ying
    Wu, Dong-yan
    Fu, Nai-kuan
    Lu, Feng-min
    Xu, Jing
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2013, 41 (04) : 1057 - 1066
  • [7] A comparison of single-lead atrial pacing with dual-chamber pacing in sick sinus syndrome
    Nielsen, Jens Cosedis
    Thomsen, Poul Erik B.
    Hojberg, Soren
    Moller, Mogens
    Vesterlund, Thomas
    Dalsgaard, Dorthe
    Mortensen, Leif S.
    Nielsen, Tonny
    Asklund, Mogens
    Friis, Elsebeth V.
    Christensen, Per D.
    Simonsen, Erik H.
    Eriksen, Ulrik H.
    Jensen, Gunnar V. H.
    Svendsen, Jesper H.
    Toff, William D.
    Healey, Jeffrey S.
    Andersen, Henning R.
    EUROPEAN HEART JOURNAL, 2011, 32 (06) : 686 - 696
  • [8] Feasibility of Atrial Sensing Via a Free-Floating Single-Pass Defibrillation Lead for Dual-Chamber Defibrillators
    Andreas Schuchert
    Michael Niehaus
    Ludwig Binner
    Roberto Belke
    Thomas Meinertz
    Journal of Interventional Cardiac Electrophysiology, 2003, 8 : 209 - 214
  • [9] Feasibility of atrial sensing via a free-floating single-pass defibrillation lead for dual-chamber defibrillators
    Schuchert, A
    Niehaus, M
    Binner, L
    Belke, R
    Meinertz, T
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2003, 8 (03) : 209 - 214
  • [10] Clinical Outcomes of Single- versus Dual-Chamber Implantable Cardioverter Defibrillators: Lessons from the Israeli ICD Registry
    Konstantino, Yuval
    Haim, Moti
    Boxer, Jeremy
    Goldenberg, Ilan
    Feldman, Alexander
    Michowitz, Yoav
    Glikson, Michael
    Suleiman, Mahmoud
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2016, 27 (06) : 718 - 723