Arrhythmia Detection in Atrioventricular, Single-Lead, Floating Atrial Dipole ICD Systems Compared with Conventional Single- and Dual-Chamber Defibrillators

被引:0
|
作者
Gausz, Flora Diana [1 ]
Lena, Kom Nangob Manuela [1 ,2 ]
Gedeon, Paul Emmanuel [1 ,3 ]
Miklos, Marton [1 ]
Benak, Attila [1 ]
Bencsik, Gabor [1 ]
Makai, Attila [1 ]
Kranyak, Dora [1 ]
Gagyi, Rita Beata [1 ]
Pap, Robert [1 ]
Saghy, Laszlo [1 ]
Szili-Torok, Tamas [1 ]
Vamos, Mate [1 ]
机构
[1] Univ Szeged, Cardiol Ctr, Dept Internal Med, Cardiac Electrophysiol Div, H-6725 Szeged, Hungary
[2] Univ Szeged, Dept Oncotherapy, H-6720 Szeged, Hungary
[3] Queen Elizabeth Univ Hosp, Neurosurg, Glasgow G51 4TF, Scotland
关键词
ICD; implantable cardioverter defibrillator; floating atrial sensing dipole; VDD; tachycardia discrimination; atrial arrythmia detection; IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS; RISK; DISCRIMINATION; FIBRILLATION; RATIONALE; SHOCKS;
D O I
10.3390/jcdd11120386
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: An atrioventricular defibrillator system with a floating atrial dipole (VDD ICD) can provide atrial sensing by a single lead. Our aim was to compare the arrhythmia detection efficacy of VDD ICDs with conventional single- (VVI) and dual-chamber (DDD) defibrillators. Methods: Data from consecutive patients undergoing ICD implantation were retrospectively analyzed. The primary endpoint was the incidence of device-detected, new-onset atrial arrhythmias, while secondary endpoints were sensing parameters, complication rates, incidence of appropriate/inappropriate ICD therapy, arrhythmic/heart failure-related hospitalizations, and all-cause mortality. Results: A total of 256 patients (mean age 64 +/- 12 years, male 75%, primary prophylaxis 28%, mean follow-up 3.7 +/- 2.4 years) were included (VVI: 93, VDD: 94, DDD: 69). Atrial arrhythmia episodes were detected more frequently by VDD systems compared to VVI ICDs (aHR 7.087; 95% CI 2.371-21.183; p < 0.001), and at a rate similar to that of DDD ICDs (aHR 1.781; 95% CI 0.737-4.301; p = 0.200). The rate of inappropriate shocks was not different among the three ICD systems. Conclusion: VDD devices revealed an advantage in atrial arrhythmia detection compared to VVI ICDs and were non-inferior to DDD systems. Their main indication may be closer monitoring in high-risk patients with atrial arrhythmias to help therapy optimization and not the improvement of tachycardia discrimination.
引用
收藏
页数:14
相关论文
共 50 条
  • [42] High incidence of device-related and lead-related complications in the dual-chamber implantable cardioverter defibrillator compared with the single-chamber version
    Takahashi, T
    Bhandari, AK
    Watanuki, M
    Cannom, DS
    Sakurada, H
    Hiraoka, M
    CIRCULATION JOURNAL, 2002, 66 (08) : 746 - 750
  • [43] Atrial sensing performance of a recently developed defibrillation lead with a free-floating atrial dipole connected to a single chamber defibrillator with enhanced atrial sensing characteristics
    Zerm, T
    Schmitz, D
    Bondke, HJ
    Lemke, B
    Wiegand, U
    Tiroke, A
    Mitzenheim, S
    Schuchert, A
    EUROPEAN HEART JOURNAL, 2003, 24 : 275 - 275
  • [44] Long-term evaluation of sensing variability of a floating atrial dipole in a single-lead defibrillator: The mechanistic basis of long-term stability of amplified atrial electrogram
    Gwag, Hye Bin
    Lee, Su Hyun
    Kim, June Soo
    Park, Kyoung-Min
    On, Young Keun
    Hwang, Gyo-Seung
    Park, Sang Weon
    Lee, Sung Ho
    Park, Seung-Jung
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2021, 336 : 67 - 72
  • [45] CLINICAL-EXPERIENCE WITH A SINGLE-PASS DUAL CHAMBER PACEMAKER LEAD COMPARED WITH SEPARATE ATRIAL AND VENTRICULAR LEADS
    BERMAN, N
    DUXBURY, G
    LIPTON, I
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (02): : 436 - 436
  • [46] The effectiveness and cost-effectiveness of dual-chamber pacemakers compared with single-chamber pacemakers for bradycardia due to atrioventricular block or sick sinus syndrome: systematic review and economic evaluation
    Castelnuovo, E
    Stein, K
    Pitt, M
    Garside, R
    Payne, E
    HEALTH TECHNOLOGY ASSESSMENT, 2005, 9 (43) : 1 - +
  • [47] Heart failure in patients with sick sinus syndrome treated with single lead atrial or dual-chamber pacing: no association with pacing mode or right ventricular pacing site
    Riahi, Sam
    Nielsen, Jens Cosedis
    Hjortshoj, Soren
    Thomsen, Pout Erik B.
    Hojberg, Soren
    Moller, Mogens
    Dalsgaard, Dorthe
    Nielsen, Tonny
    Asklund, Mogens
    Friis, Elsebeth V.
    Christensen, Per D.
    Simonsen, Erik H.
    Eriksen, Ulrik H.
    Jensen, Gunnar V. H.
    Svendsen, Jesper H.
    Toff, William D.
    Healey, Jeffrey S.
    Andersen, Henning R.
    EUROPACE, 2012, 14 (10): : 1475 - 1482
  • [48] Six-lead electrocardiography compared to single-lead electrocardiography and photoplethysmography of a wrist-worn device for atrial fibrillation detection controlled by premature atrial or ventricular contractions: six is smarter than one
    Bacevicius, Justinas
    Taparauskaite, Neringa
    Kundelis, Ricardas
    Sokas, Daivaras
    Butkuviene, Monika
    Stankeviciute, Guoste
    Abramikas, Zygimantas
    Pilkiene, Aiste
    Dvinelis, Ernestas
    Staigyte, Justina
    Marinskiene, Julija
    Audzijoniene, Deimile
    Petrylaite, Marija
    Jukna, Edvardas
    Karuzas, Albinas
    Juknevicius, Vytautas
    Jakaite, Rusne
    Basyte-Bacevice, Viktorija
    Bileisiene, Neringa
    Badaras, Ignas
    Kiseliute, Margarita
    Zarembaite, Gintare
    Gudauskas, Modestas
    Jasiunas, Eugenijus
    Johnson, Linda
    Marozas, Vaidotas
    Aidietis, Audrius
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [49] Comparison of Inappropriate Shocks and Other Health Outcomes Between Single- and Dual-Chamber Implantable Cardioverter-Defibrillators for Primary Prevention of Sudden Cardiac Death: Results From the Cardiovascular Research Network Longitudinal Study of Implantable Cardioverter-Defibrillators
    Peterson, Pamela N.
    Greenlee, Robert T.
    Go, Alan S.
    Magid, David J.
    Cassidy-Bushrow, Andrea
    Garcia-Montilla, Romel
    Glenn, Karen A.
    Gurwitz, Jerry H.
    Hammill, Stephen C.
    Hayes, John
    Kadish, Alan
    Reynolds, Kristi
    Sharma, Param
    Smith, David H.
    Varosy, Paul D.
    Vidaillet, Humberto
    Zeng, Chan X.
    Normand, Sharon-Lise T.
    Masoudi, Frederick A.
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2017, 6 (11):