Experimental evaluation of a novel demountable shear connection system in prefabricated steel-concrete composite beams

被引:0
|
作者
Yang, Hailin [1 ,2 ]
Yu, Pengcheng [3 ]
Zheng, Yan [1 ,2 ]
机构
[1] Guilin Univ Technol, Guangxi Key Lab Green Bldg Mat & Construct Industr, Guilin 541004, Peoples R China
[2] Guilin Univ Technol, Coll Civil Engn, Guilin 541004, Peoples R China
[3] Univ South China, Coll Civil Engn, Hengyang 421001, Peoples R China
关键词
Prefabricated steel-concrete composite beam; Demountable shear connector; Steel shot particles; Push-out test; Shear behavior; BEHAVIOR; PERFORMANCE; DESIGN;
D O I
10.1016/j.conbuildmat.2025.140624
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Unlike traditional studies focused on developing demountable shear connectors for prefabricated steel-concrete composite structures, this paper introduces a novel demountable shear connection system that replaces cement- based fillers with steel shot particles. The proposed system consists of a partially-threaded no-headed stud (PTNHS), two washers of different diameters, a cup-shaped steel tube, and steel shot particles. Using steel shot particles as filler eliminates the need for curing under specific time and temperature conditions, thereby reducing traffic interruptions. This research conducts a preliminary push-out test to investigate the mechanical behavior of the proposed system and evaluate its installation and disassembly procedures. Experimental results revealed that specimens failed due to shear except two specimens failed due to welding defects. The fracture surfaces of the PTNHS shear connectors were located above the weld collar. Only localized concrete crushing was observed in precast concrete slabs. The load-slip curves of PTNHS shear connectors within the same specimen exhibited similar patterns. The maximum average shear stiffnesses of PTNHS shear connectors was only 27.2 % of headed studs shear connectors. The slip of all specimens at the peak load exceeded 6 mm. Adding a 5 mm thick washer with a larger-diameter significantly improved shear stiffness but had no effect on shear capacity. Mixing steel shot particles with resin increased shear capacity but reduced shear stiffness. The average ultimate load of PFSSC-19(16) specimens was 12.7 % and 15.1 % lower than that of bolted shear connectors and headed stud shear connectors, respectively. However, the average ultimate loads of PTNHS shear connectors with a 22 mm diameter were only about two-thirds of headed stud shear connector. Finally, it was found that the shear capacities of PTNHS shear connectors calculated using China code GB50017 were in good agreement with the experimental results.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Research Progress of Prefabricated Steel-Concrete Composite Shear Wall
    Liang, Wentao
    Yang, Yuanlong
    Liu, Yufei
    He, Longfu
    Hu, Hui
    PROCEEDINGS OF THE 2024 8TH INTERNATIONAL CONFERENCE ON CIVIL ARCHITECTURE AND STRUCTURAL ENGINEERING, ICCASE 2024, 2024, 33 : 597 - 603
  • [42] Flexural Behavior of New Demountable Steel-Concrete Composite Beam with Novel Demountable Connectors
    Liu, Jicheng
    Cen, Kaiwen
    Wang, Zhexiong
    Li, Wei
    Shi, Lili
    BUILDINGS, 2025, 15 (05)
  • [43] Proof of concept of a demountable steel-concrete composite flooring system
    Gîrbacea, Ioan Andrei
    Nijgh, Martin Paul
    Veljkovic, Milan
    ce/papers, 2019, 3 (3-4): : 571 - 576
  • [44] Finite Element Modeling of Steel-concrete Composite Beams with Different Shear Connection Degrees
    Zheng, Xing
    Li, Wenxian
    Huang, Qiao
    Wang, Bing
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2021, 21 (01) : 381 - 391
  • [45] Finite Element Modeling of Steel-concrete Composite Beams with Different Shear Connection Degrees
    Xing Zheng
    Wenxian Li
    Qiao Huang
    Bing Wang
    International Journal of Steel Structures, 2021, 21 : 381 - 391
  • [46] Parametric Modal Dynamic Analysis of Steel-Concrete Composite Beams with Deformable Shear Connection
    Machado, Wanderson G.
    Neves, Francisco de A.
    de Sousa, Joao Batista M., Jr.
    LATIN AMERICAN JOURNAL OF SOLIDS AND STRUCTURES, 2017, 14 (02): : 335 - 356
  • [47] Experimental investigation of steel-concrete composite beams with different degrees of shear connection under monotonic and fatigue loads
    Wang, Bing
    Huang, Qiao
    Liu, Xiaoling
    Li, Wenxian
    ADVANCES IN STRUCTURAL ENGINEERING, 2018, 21 (02) : 227 - 240
  • [48] Behavior of downstand simply supported steel-concrete composite beam applying friction based demountable shear connection
    Fodor, Jovan
    Schäfer, Markus
    ce/papers, 2021, 4 (2-4) : 809 - 816
  • [49] Strength of shear connectors in steel-concrete composite beams
    Madheswaran, C.K.
    Natarajan, K.
    Prakash, A.
    Journal of the Institution of Engineers (India): Civil Engineering Division, 2007, 88 (AUG.): : 14 - 20
  • [50] Experimental study on shear strength of steel-concrete composite beams with web opening
    Wang, P. (wangpengletter@163.com), 2013, Tsinghua University (30):