Experimental evaluation of a novel demountable shear connection system in prefabricated steel-concrete composite beams

被引:0
|
作者
Yang, Hailin [1 ,2 ]
Yu, Pengcheng [3 ]
Zheng, Yan [1 ,2 ]
机构
[1] Guilin Univ Technol, Guangxi Key Lab Green Bldg Mat & Construct Industr, Guilin 541004, Peoples R China
[2] Guilin Univ Technol, Coll Civil Engn, Guilin 541004, Peoples R China
[3] Univ South China, Coll Civil Engn, Hengyang 421001, Peoples R China
关键词
Prefabricated steel-concrete composite beam; Demountable shear connector; Steel shot particles; Push-out test; Shear behavior; BEHAVIOR; PERFORMANCE; DESIGN;
D O I
10.1016/j.conbuildmat.2025.140624
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Unlike traditional studies focused on developing demountable shear connectors for prefabricated steel-concrete composite structures, this paper introduces a novel demountable shear connection system that replaces cement- based fillers with steel shot particles. The proposed system consists of a partially-threaded no-headed stud (PTNHS), two washers of different diameters, a cup-shaped steel tube, and steel shot particles. Using steel shot particles as filler eliminates the need for curing under specific time and temperature conditions, thereby reducing traffic interruptions. This research conducts a preliminary push-out test to investigate the mechanical behavior of the proposed system and evaluate its installation and disassembly procedures. Experimental results revealed that specimens failed due to shear except two specimens failed due to welding defects. The fracture surfaces of the PTNHS shear connectors were located above the weld collar. Only localized concrete crushing was observed in precast concrete slabs. The load-slip curves of PTNHS shear connectors within the same specimen exhibited similar patterns. The maximum average shear stiffnesses of PTNHS shear connectors was only 27.2 % of headed studs shear connectors. The slip of all specimens at the peak load exceeded 6 mm. Adding a 5 mm thick washer with a larger-diameter significantly improved shear stiffness but had no effect on shear capacity. Mixing steel shot particles with resin increased shear capacity but reduced shear stiffness. The average ultimate load of PFSSC-19(16) specimens was 12.7 % and 15.1 % lower than that of bolted shear connectors and headed stud shear connectors, respectively. However, the average ultimate loads of PTNHS shear connectors with a 22 mm diameter were only about two-thirds of headed stud shear connector. Finally, it was found that the shear capacities of PTNHS shear connectors calculated using China code GB50017 were in good agreement with the experimental results.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Shear Behaviour and Calculation Methods of Bearing-Shear Connectors for Prefabricated Steel-Concrete Composite Beams
    Zheng, Zhichao
    Zou, Yang
    Chou, Yaling
    Qin, Fengjiang
    Chen, Fengmin
    Di, Jin
    Zhang, Zhigang
    MATERIALS, 2023, 16 (13)
  • [32] Experimental Study on Longitudinal Shear Behavior of Prefabricated Steel-Concrete Composite Beams with Hidden Continuous Channels and Shear Key Connections
    Huang, Da
    Nie, Xin
    Fan, Jiansheng
    Ding, Ran
    JOURNAL OF STRUCTURAL ENGINEERING, 2025, 151 (03)
  • [33] Performances of Steel-Concrete Composite Construction with Demountable Shear Connectors - Review
    Al-Muslihand, Abdulhadi Th.
    Al-Hadithy, Laith Kh.
    2ND INTERNATIONAL CONFERENCE ON SUSTAINABLE ENGINEERING TECHNIQUES (ICSET 2019), 2019, 518
  • [34] Experimental evaluation of effective width in steel-concrete composite beams
    Amadio, C
    Fedrigo, C
    Fragiacomo, M
    Macorini, L
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2004, 60 (02) : 199 - 220
  • [35] HIGH TEMPERATURE PUSH-OUT TESTS ON DEMOUNTABLE SHEAR CONNECTORS OF STEEL-CONCRETE COMPOSITE BEAMS
    Mansilla, Roberto
    Espinós, Ana
    Payá-Faforteza, Ignacio
    Odenbreit, Christoph
    Romero, Manuel L.
    ce/papers, 2023, 6 (3-4) : 2074 - 2079
  • [36] Finite Element Analyses of Demountable Shear Connection in Cold-Formed Steel-Concrete Composite Beam Based on Experimental Data
    Žuvelek, Vlaho
    Ćurković, Ivan
    Lukačević, Ivan
    Rajić, Andrea
    ce/papers, 2023, 6 (3-4) : 213 - 219
  • [37] A macro element of demountable bolted steel-concrete composite connections for a novel prefabricated concrete sandwich wall panel structure
    Xiong, Feng
    Zou, Hongyun
    Lu, Yang
    ENGINEERING STRUCTURES, 2023, 293
  • [38] Vibrations of steel-concrete composite beams with damaged connection
    Morassi, A
    PROCEEDINGS OF ISMA 2002: INTERNATIONAL CONFERENCE ON NOISE AND VIBRATION ENGINEERING, VOLS 1-5, 2002, : 357 - 366
  • [39] Shear behavior of groove-plate nested connectors in prefabricated steel-concrete composite beams
    Jiang, Jinlong
    Zhou, Zhixiang
    Liang, Huaping
    Zhang, Zhongya
    Tang, Junhua
    Li, Xin
    Zou, Yang
    Structures, 2025, 75
  • [40] Study on Shear Behavior of Multi-Bolt Connectors for Prefabricated Steel-Concrete Composite Beams
    Wang, Wei
    Zhang, Xie-dong
    Zhou, Xi-long
    Wu, Lin
    Zhu, Hao-jie
    FRONTIERS IN MATERIALS, 2021, 8