Comparison of oropharyngeal leak pressure of I-gel™ and Blockbuster™ laryngeal mask airway in anaesthetized pediatric patients

被引:3
|
作者
Selvin, Caren Candace [1 ]
Singariya, Geeta [1 ]
Bihani, Pooja [1 ]
Kamal, Manoj [2 ]
Paliwal, Naveen [1 ]
Ujwal, Shobha [1 ]
机构
[1] Dr SN Med Coll Jodhpur, Dept Anesthesiol & Crit Care, Jodhpur, India
[2] All India Inst Med Sci Jodhpur, Dept Anesthesiol & Crit Care, 123 Vaishali Ave,Jhanwar Rd, Jodhpur 342008, Rajasthan, India
来源
ANESTHESIA AND PAIN MEDICINE | 2023年 / 18卷 / 01期
关键词
Blockbuster LMA; I-gel; Pediatric anesthesia; Supraglottic airways; I-GEL; GENERAL-ANESTHESIA; CHILDREN; PERFORMANCE; DEVICES;
D O I
10.17085/apm.22209
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Supraglottic airways (SGA) are increasingly used in pediatric anesthesia. Among SGA, I-gel (TM) is a commonly used device in pediatric patients. The Blockbuster (TM) laryngeal mask airway (LMA) is latest addition in pediatric airway armamentarium. This study was conducted to compare the clinical performance of I-gel (TM) and Blockbuster (TM) LMA in pediatric patients. Methods: A total of 140 children aged 1-5 years, who were undergoing elective surgery, were randomized into two groups either I-gel (TM) (Group I) or Blockbuster (TM) LMA (Group B). Air-way was secured with appropriate-sized LMA according to group allocation under general anesthesia. The primary objective of study was oropharyngeal leak pressures (OPLP), and secondary objectives were number of attempts of device insertion, success rate, ease of LMA insertion, hemodynamic parameters, and postoperative pharyngolaryngeal morbidities. Results: The mean OPLP was significantly higher for I-gel (TM) compared to Blockbuster (TM) LMA (27.97 +/- 1.65 vs. 26.04 +/- 2.12; P < 0.001). The devices were successfully inserted on the first attempt in 97.14% and 90% of the Group I and Group B respectively. The insertion time, ease of insertion, hemodynamic parameters and postoperative complications were compa-rable between groups. Conclusions: The I-gel (TM) was more efficacious device in term of OPLP than Blockbuster (TM) LMA for positive pressure ventilation in pediatric patients undergoing short surgical proce-dures under general anesthesia.
引用
收藏
页数:121
相关论文
共 50 条
  • [31] A RANDOMIZED COMPARISON OF I-GEL AND AMBU AURAGAIN TM LARYNGEAL MASK AIRWAY IN PATIENTS WITH SIMULATED CERVICAL IMMOBILIZATION
    Hur, Min
    Kim, Tae Kyong
    Lee, Hyung-Chul
    ANESTHESIA AND ANALGESIA, 2019, 128 : 17 - 20
  • [32] Comparison between I-Gel and Classic Laryngeal Mask Airway for Airway Management of Patients with Anticipated Difficult Airway: A Randomised Clinical Trial
    Raman, Rajesh
    Gautam, Shefali
    Sonkar, Suraj
    Prabha, Rati
    Alam, Sharif
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2021, 15 (10) : UC10 - UC13
  • [33] Comparison of Laryngeal Mask Airway Supreme and Laryngeal Mask Airway Proseal with respect to oropharyngeal leak pressure during laparoscopic cholecystectomy: a randomised controlled trial
    Belena, Jose M.
    Nunez, Monica
    Anta, Diego
    Carnero, Maria
    Gracia, Jose L.
    Ayala, Jose L.
    Alvarez, Raquel
    Yuste, Javier
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2013, 30 (03) : 119 - 123
  • [34] Comparison of I-gel with Classic Laryngeal Mask Airway Regarding the Ease of Use and Clinical Performance
    Ari, Dilek Erdogan
    Ar, Arzu Yildirim
    Karip, Ceren Sanli
    Siyahkoc, Incifer
    Arslan, Ahmet Hakan
    Akgun, Fatma Nur
    TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2015, 43 (05) : 299 - 303
  • [35] Comparison of endotracheal intubation, laryngeal mask airway, and I-gel in children undergoing strabismus surgery
    Allahyari, Elaheh
    Azimi, Ali
    Zarei, Hamed
    Bamdad, Shahram
    JOURNAL OF RESEARCH IN MEDICAL SCIENCES, 2021, 26 (01):
  • [36] Are nurses able to perform blind intubation? Randomized comparison of I-gel and laryngeal mask airway
    Ladny, Jerzy R.
    Bielski, Karol
    Szarpak, Lukasz
    Cieciel, Michal
    Konski, Roman
    Smereka, Jacek
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2017, 35 (05): : 786 - 787
  • [37] Comparison of the clinical performance of airway management with the i-gel® and laryngeal mask airway Supreme™ in geriatric patients: a prospective and randomized study
    In, Chi Bum
    Cho, Sung-Ae
    Lee, Seok-Jin
    Sung, Tae-Yun
    Cho, Choon-Kyu
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2019, 72 (01) : 39 - 46
  • [38] Comparison of fibrescope guided intubation via the classic laryngeal mask airway and i-gel in a manikin
    de Lloyd, L.
    Hodzovic, I.
    Voisey, S.
    Wilkes, A. R.
    Latto, I. P.
    ANAESTHESIA, 2010, 65 (01) : 36 - 43
  • [39] Emergency airway management by paramedics: comparison between standard endotracheal intubation, laryngeal mask airway, and I-gel
    Leventis, Charalampos
    Chalkias, Athanasios
    Sampanis, Michail A.
    Foulidou, Xanthipi
    Xanthos, Theodoros
    EUROPEAN JOURNAL OF EMERGENCY MEDICINE, 2014, 21 (05) : 371 - 373
  • [40] Reply to Letter: Comparison of the I-gel supraglottic airway as a conduit for tracheal intubation with the intubating laryngeal mask airway
    Michalek, Pavel
    Donaldson, William
    RESUSCITATION, 2010, 81 (07) : 911 - 911