Comparison of oropharyngeal leak pressure of I-gel™ and Blockbuster™ laryngeal mask airway in anaesthetized pediatric patients

被引:3
|
作者
Selvin, Caren Candace [1 ]
Singariya, Geeta [1 ]
Bihani, Pooja [1 ]
Kamal, Manoj [2 ]
Paliwal, Naveen [1 ]
Ujwal, Shobha [1 ]
机构
[1] Dr SN Med Coll Jodhpur, Dept Anesthesiol & Crit Care, Jodhpur, India
[2] All India Inst Med Sci Jodhpur, Dept Anesthesiol & Crit Care, 123 Vaishali Ave,Jhanwar Rd, Jodhpur 342008, Rajasthan, India
来源
ANESTHESIA AND PAIN MEDICINE | 2023年 / 18卷 / 01期
关键词
Blockbuster LMA; I-gel; Pediatric anesthesia; Supraglottic airways; I-GEL; GENERAL-ANESTHESIA; CHILDREN; PERFORMANCE; DEVICES;
D O I
10.17085/apm.22209
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Supraglottic airways (SGA) are increasingly used in pediatric anesthesia. Among SGA, I-gel (TM) is a commonly used device in pediatric patients. The Blockbuster (TM) laryngeal mask airway (LMA) is latest addition in pediatric airway armamentarium. This study was conducted to compare the clinical performance of I-gel (TM) and Blockbuster (TM) LMA in pediatric patients. Methods: A total of 140 children aged 1-5 years, who were undergoing elective surgery, were randomized into two groups either I-gel (TM) (Group I) or Blockbuster (TM) LMA (Group B). Air-way was secured with appropriate-sized LMA according to group allocation under general anesthesia. The primary objective of study was oropharyngeal leak pressures (OPLP), and secondary objectives were number of attempts of device insertion, success rate, ease of LMA insertion, hemodynamic parameters, and postoperative pharyngolaryngeal morbidities. Results: The mean OPLP was significantly higher for I-gel (TM) compared to Blockbuster (TM) LMA (27.97 +/- 1.65 vs. 26.04 +/- 2.12; P < 0.001). The devices were successfully inserted on the first attempt in 97.14% and 90% of the Group I and Group B respectively. The insertion time, ease of insertion, hemodynamic parameters and postoperative complications were compa-rable between groups. Conclusions: The I-gel (TM) was more efficacious device in term of OPLP than Blockbuster (TM) LMA for positive pressure ventilation in pediatric patients undergoing short surgical proce-dures under general anesthesia.
引用
收藏
页数:121
相关论文
共 50 条
  • [1] The supraglottic airway I-gel in comparison with ProSeal laryngeal mask airway and classic laryngeal mask airway in anaesthetized patients
    Shin, Won-Jung
    Cheong, Yu-Seon
    Yang, Hong-Seuk
    Nishiyama, Tomoki
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (07) : 598 - 601
  • [2] A RANDOMIZED COMPARISON OF THE I-GEL WITH THE PROSEAL LARYNGEAL MASK AIRWAY IN PEDIATRIC PATIENTS
    Fukuhara, A.
    Okutani, R.
    Oda, Y.
    ANESTHESIA AND ANALGESIA, 2012, 114
  • [3] Mucosal pressure and oropharyngeal leak pressure with the ProSeal versus laryngeal mask airway in anaesthetized paralysed patients
    Keller, C
    Brimacombe, J
    BRITISH JOURNAL OF ANAESTHESIA, 2000, 85 (02) : 262 - 266
  • [4] Comparison of two supraglottic airway devices, the i-gel airway and the ProSeal laryngeal mask airway, in non-paralysed anaesthetized patients
    Jain, A.
    Luthra, A.
    Bhukal, I.
    Bala, I.
    BRITISH JOURNAL OF ANAESTHESIA, 2016, 116 (06) : E907 - E907
  • [5] Chronological change in oropharyngeal leak pressure of pediatric i-gel™
    Yoshikawa, Yusuke
    Hirata, Naoyuki
    Nawa, Yuko
    Yamakage, Michiaki
    PEDIATRIC ANESTHESIA, 2019, 29 (01) : 107 - 108
  • [6] Clinical Performance of I-gel® and BlockBuster™ Laryngeal Mask Airway in Adult Patients during General Anesthesia: A Randomized Comparison
    Das, Prerna Prabhat
    Tiwari, Tanmay
    Raman, Rajesh
    Gautam, Shefali
    Kushwaha, B. B.
    Kumar, Yatendra
    INTERNATIONAL JOURNAL OF APPLIED AND BASIC MEDICAL RESEARCH, 2024, 14 (02) : 108 - 113
  • [7] Comparison between i-gel airway an the proseal laryngeal mask airway in pediatric patients undergoing general anesthesia
    Acharya, R.
    Dave, N. M.
    PEDIATRIC ANESTHESIA AND CRITICAL CARE JOURNAL, 2016, 4 (02): : 97 - 102
  • [8] A randomized comparison of the i-gel and the ProSeal laryngeal mask airway in pediatric patients: performance and fiberoptic findings
    Fukuhara, Aya
    Okutani, Ryu
    Oda, Yutaka
    JOURNAL OF ANESTHESIA, 2013, 27 (01) : 1 - 6
  • [9] A randomized comparison of the i-gel and the ProSeal laryngeal mask airway in pediatric patients: performance and fiberoptic findings
    Aya Fukuhara
    Ryu Okutani
    Yutaka Oda
    Journal of Anesthesia, 2013, 27 : 1 - 6
  • [10] Comparing i-gel and Ambu AuraOnce laryngeal mask airway in pediatric patients Reply
    Aqil, Mansoor
    Alzahem, Abdulrahman M.
    SAUDI MEDICAL JOURNAL, 2017, 38 (12) : 1262 - 1263