To study the quenching characteristics of materials in a cryogenic liquid bath transient temperature measurements of high accuracy are necessary. Thermocouple is an ideal tool for this application because of its low self-heat capacity. However, they require calibration before usage that require multiple fixed-point temperatures. The common fixed-point temperatures are the water-ice melting temperature, the dry ice sublimation temperature, and the boiling temperature of liquid nitrogen. It is important to note that there are uncertainties associated with dry ice sublimation and liquid nitrogen boiling temperature inherent to the heat and mass transport phenomenon at their phase-changing interface or inside the bulk medium. The dry ice temperature is influenced by the mass transport phenomenon occurring at the interface between the dry ice and the ambient surrounding it. In a typical lab environment, dry ice temperature is significantly lower than the commonly quoted sublimation temperature of -78.5 degrees C at 1.013 bar. In the case of liquid nitrogen stored in a cryostat, temperature gradients develop in the liquid bath. This paper describes a protocol for calibrating thermocouples by accurately defining and using fixed-point temperatures of dry ice in a saturated environment and a liquid nitrogen slush.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] FURNACES FOR CALIBRATING METAL THERMOCOUPLES UP TO 2000-2500 DEGREES C
    DANISHEV.SK
    SMIRNOVA, NI
    MEASUREMENT TECHNIQUES-USSR, 1965, (12): : 1126 - &
  • [42] Miniature fixed-point cells and their integration in self-calibrating thermocouples
    Boguhn, D
    Bernhard, F
    Lehmann, H
    Tegeler, E
    TEMPERATURE '98, 1998, 1379 : 25 - 34
  • [43] Calibrating cryogenic temperature of TEM specimens using EELS
    Kumar, Abinash
    Tiukalova, Elizaveta
    Venkatraman, Kartik
    Lupini, Andrew
    Hachtel, Jordan A.
    Chi, Miaofang
    ULTRAMICROSCOPY, 2024, 265
  • [44] CALIBRATION OF COPPER-CONSTANTAN THERMOCOUPLES AT LOW TEMPERATURES
    BONDAREV.AP
    MEASUREMENT TECHNIQUES-USSR, 1970, (03): : 411 - &
  • [45] APPLICATION OF SUCTION THERMOCOUPLES FOR MEASURING HIGH GAS TEMPERATURES
    KARASINA, ES
    KROPP, LI
    MINTS, MS
    INDUSTRIAL LABORATORY, 1962, 28 (05): : 665 - 666
  • [46] MEASUREMENT OF HIGH GAS TEMPERATURES WITH FINE WIRE THERMOCOUPLES
    BRADLEY, D
    MATTHEWS, KJ
    JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 1968, 10 (04): : 299 - &
  • [47] MEASURING THE TEMPERATURES OF GAS TURBINES WITH FILM THERMOCOUPLES.
    Simbirskii, D.F.
    Frid, A.M.
    Anikin, A.Ya.
    Grigor'ev, L.S.
    Lotarev, V.A.
    Zlenko, A.N.
    Blyumin, Ya.I.
    Thermal Engineering (English translation of Teploenergetika), 1972, 19 (06): : 65 - 69
  • [48] NEW ALLOYS HELP THERMOCOUPLES HANDLE HIGHER TEMPERATURES
    不详
    ADVANCED MATERIALS & PROCESSES, 1991, 139 (03): : 40 - 41
  • [50] Maximum Lowering of Temperatures in Composite Semiconductor Thermocouples.
    Semenyuk, V.A.
    Nechiporuk, O.L.
    Izvestiya Vysshikh Uchebnykh Zavedenij i Energeticheskikh Ob''edinenij Sng. Energetika, 1976, (02): : 105 - 110