A protocol for accurately calibrating thermocouples at cryogenic temperatures

被引:0
|
作者
Purandare, A. S. [1 ]
Vanapalli, S. [1 ]
机构
[1] Univ Twente, Fac Sci & Technol, Appl Thermal Sci Lab, Post Bus 217, NL-7500 AE Enschede, Netherlands
关键词
THERMAL STRATIFICATION;
D O I
10.1088/1757-899X/1301/1/012079
中图分类号
O414.1 [热力学];
学科分类号
摘要
To study the quenching characteristics of materials in a cryogenic liquid bath transient temperature measurements of high accuracy are necessary. Thermocouple is an ideal tool for this application because of its low self-heat capacity. However, they require calibration before usage that require multiple fixed-point temperatures. The common fixed-point temperatures are the water-ice melting temperature, the dry ice sublimation temperature, and the boiling temperature of liquid nitrogen. It is important to note that there are uncertainties associated with dry ice sublimation and liquid nitrogen boiling temperature inherent to the heat and mass transport phenomenon at their phase-changing interface or inside the bulk medium. The dry ice temperature is influenced by the mass transport phenomenon occurring at the interface between the dry ice and the ambient surrounding it. In a typical lab environment, dry ice temperature is significantly lower than the commonly quoted sublimation temperature of -78.5 degrees C at 1.013 bar. In the case of liquid nitrogen stored in a cryostat, temperature gradients develop in the liquid bath. This paper describes a protocol for calibrating thermocouples by accurately defining and using fixed-point temperatures of dry ice in a saturated environment and a liquid nitrogen slush.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] THERMOCOUPLES FOR MEASURING HIGH TEMPERATURES IN A VACUUM
    PLETENETSKII, GE
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1967, (01): : 214 - +
  • [22] The influence of thermocouples on the measurement of grinding temperatures
    Fang, Congfu
    Huang, Hui
    Xu, Xipeng
    ADVANCES IN MACHINING AND MANUFACTURING TECHNOLOGY IX, 2008, 375-376 : 549 - 552
  • [23] MEASURING MELT TEMPERATURES - THERMOCOUPLES OR PYROMETERS
    GALSKOY, A
    WANG, KK
    PLASTICS ENGINEERING, 1978, 34 (11) : 42 - 45
  • [24] A study of the Fractal fluctuation characteristic in the calibration of the cryogenic thermocouples
    Zhang, P
    Wu, YY
    Xu, YX
    Wang, RZ
    Murakami, M
    CRYOGENICS AND REFRIGERATION - PROCEEDINGS OF ICCR'2003, 2003, : 777 - 780
  • [25] Fractal study of the fluctuation characteristic in the calibration of the cryogenic thermocouples
    Zhang, P
    Xu, YX
    Wang, RZ
    Murakami, M
    CRYOGENICS, 2003, 43 (01) : 53 - 58
  • [26] Studying and calibrating thermocouples: A laboratory exercise at the Technological Educational Institute of Crete
    Makris, J. P.
    Vardiambasis, I. O.
    Saltas, V.
    Petrakis, N.
    2nd Balkan Region Conference on Engineering Education, Conference Proceedings: BRIDGES FOR CO-OPERATION IN ENGINEERING EDUCATION, 2003, : 120 - 123
  • [27] METHOD FOR ACCURATELY CALIBRATING TILTING STAGES IN ELECTRON MICROSCOPE
    SHEININ, SS
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1966, 37 (02): : 232 - &
  • [28] Calibrating device for measuring engine thrust accurately and conveniently
    Yang, Shengfa
    Fang, Ding
    Li, Yuanye
    Xibei Gongye Daxue Xuebao/Journal of Northwestern Polytechnical University, 1997, 15 (03): : 338 - 342
  • [29] CROSS-CONDUCTION ERRORS IN THERMOCOUPLES . CORRECTION OF LONG SWAGED THERMOCOUPLES AT HIGH TEMPERATURES
    LARRAIN, J
    BONILLA, CF
    NUCLEAR ENGINEERING AND DESIGN, 1968, 8 (02) : 251 - &
  • [30] SOME SOURCES OF ERRORS IN MEASURING TEMPERATURES WITH THERMOCOUPLES
    MIKHEEV, VS
    INDUSTRIAL LABORATORY, 1960, 26 (05): : 691 - 691