A protocol for accurately calibrating thermocouples at cryogenic temperatures

被引:0
|
作者
Purandare, A. S. [1 ]
Vanapalli, S. [1 ]
机构
[1] Univ Twente, Fac Sci & Technol, Appl Thermal Sci Lab, Post Bus 217, NL-7500 AE Enschede, Netherlands
关键词
THERMAL STRATIFICATION;
D O I
10.1088/1757-899X/1301/1/012079
中图分类号
O414.1 [热力学];
学科分类号
摘要
To study the quenching characteristics of materials in a cryogenic liquid bath transient temperature measurements of high accuracy are necessary. Thermocouple is an ideal tool for this application because of its low self-heat capacity. However, they require calibration before usage that require multiple fixed-point temperatures. The common fixed-point temperatures are the water-ice melting temperature, the dry ice sublimation temperature, and the boiling temperature of liquid nitrogen. It is important to note that there are uncertainties associated with dry ice sublimation and liquid nitrogen boiling temperature inherent to the heat and mass transport phenomenon at their phase-changing interface or inside the bulk medium. The dry ice temperature is influenced by the mass transport phenomenon occurring at the interface between the dry ice and the ambient surrounding it. In a typical lab environment, dry ice temperature is significantly lower than the commonly quoted sublimation temperature of -78.5 degrees C at 1.013 bar. In the case of liquid nitrogen stored in a cryostat, temperature gradients develop in the liquid bath. This paper describes a protocol for calibrating thermocouples by accurately defining and using fixed-point temperatures of dry ice in a saturated environment and a liquid nitrogen slush.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] METHOD FOR CALIBRATING THERMOCOUPLES IN VACUUM
    BORISOV, BY
    KULBAKA, YS
    TSOKUR, AK
    MEASUREMENT TECHNIQUES-USSR, 1968, (04): : 551 - &
  • [2] SIMPLE METHOD OF CALIBRATING THERMOCOUPLES
    SIMA, V
    MISEK, K
    BEDNAR, J
    CZECHOSLOVAK JOURNAL OF PHYSICS, 1973, 23 (05) : 577 - 580
  • [3] CALIBRATION OF THERMOCOUPLES AT TEMPERATURES ABOVE 2000 DEGREES C .I. FURNACE FOR CALIBRATING THERMOCOUPLES UP TO 2500 DEGREES C
    LAPP, GB
    POPOVA, DI
    VASILEV, LM
    MEASUREMENT TECHNIQUES-USSR, 1967, (02): : 241 - &
  • [4] Material behaviour at low temperatures for calibrating cryogenic machining numerical simulations
    Bertolini, R.
    Bruschi, S.
    Ghiotti, A.
    Haugou, G.
    Morvan, H.
    Dubar, L.
    17TH CIRP CONFERENCE ON MODELLING OF MACHINING OPERATIONS (17TH CIRP CMMO), 2019, 82 : 344 - 349
  • [5] CALIBRATING THERMOCOUPLES PERFECTLY IS NO PIPE DREAM
    LOWE, JF
    DESIGN NEWS, 1973, 28 (13) : 96 - 97
  • [6] METHOD FOR CALIBRATING COPPER-CONSTANTAN THERMOCOUPLES AT NEGATIVE TEMPERATURES BY MEANS OF BOILING POINT OF WATER
    BONDAREVA, AP
    MEASUREMENT TECHNIQUES-USSR, 1969, (10): : 1428 - +
  • [7] HIGHLY SENSITIVE CRYOGENIC THERMOCOUPLES
    CHERENKOV, VA
    TSAPIN, AI
    KHANGULOV, SV
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1990, 33 (02) : 495 - 495
  • [8] CALIBRATING CRYOGENIC SENSORS
    STONE, OC
    SCHNEIDER, DB
    INSTRUMENTATION TECHNOLOGY, 1967, 14 (04): : 53 - +
  • [9] Boiling-point apparatus for calibrating thermocouples
    De Vries, T
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1927, 19 (01): : 1311 - 1311
  • [10] Self-calibrating thermocouples - Modeling and design
    Lehmann, H
    Bernhard, F