Voltammetric and flow amperometric determination of drug guaifenesin in pharmaceutical and biological samples using screen-printed sensor with boron doped diamond electrode

被引:1
|
作者
Keliskova, Pavlina [1 ]
Matvieiev, Oleksandr [1 ]
Jirouskova, Eliska [2 ]
Sokolova, Romana [2 ]
Janikova, Lenka [1 ]
Behul, Miroslav [3 ]
Selesovska, Renata [1 ]
机构
[1] Univ Pardubice, Inst Environm & Chem Engn, Fac Chem Technol, Studentska 573, Pardubice 53210, Czech Republic
[2] Czech Acad Sci, J Heyrovsky Inst Phys Chem, Dolejskova 3, Prague 18223, Czech Republic
[3] Slovak Univ Technol Bratislava, Inst Elect & Photon, Fac Elect Engn & Informat Technol, Ilkovicova 3, Bratislava 81219, Slovakia
关键词
Guaifenesin; Screen-printed sensor; Boron-doped diamond electrode; Voltammetry; Flow injection analysis with electrochemical detection; Spectroelectrochemistry; MULTIWALLED CARBON NANOTUBE; MASS-SPECTROMETRY METHOD; GAS-CHROMATOGRAPHY; PARACETAMOL; PHENYLEPHRINE; HYDROCHLORIDE; SULFATE; COUGH; SERUM; CELL;
D O I
10.1016/j.talanta.2024.126809
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
New voltammetric and flow amperometric methods for the determination of guaifenesin (GFE) using a perspective screen-printed sensor (SPE) with boron-doped diamond electrode (BDDE) were developed. The electrochemical oxidation of GFE was studied on the surface of the oxygen-terminated BDDE of the sensor. The GFE provided two irreversible anodic signals at a potential of 1.0 and 1.1 V (vs. Ag|AgCl|KCl sat.) in Britton- Robinson buffer (pH 2), which was chosen as the supporting electrolyte for all measurements. First, a voltammetric method based on differential pulse voltammetry was developed and a low detection limit (LOD = 41 nmol L-1), a wide linear dynamic range (LDR = 0.1-155 mu mol L-1), and a good recovery in the analysis of model and pharmaceutical samples (RSD <3.0 %) were obtained. In addition, this sensor demonstrated excellent sensitivity and reproducibility in the analysis of biological samples (RSD <3.2 %), where the analysis took place in a drop of serum (50 mu L) without pretreatment and additional electrolyte. Subsequently, SP/BDDE was incorporated into a flow-through 3D printed electrochemical cell and a flow injection analysis method with electrochemical detection (FIA-ED) was developed, resulting in excellent analytical parameters (LOD = 86 nmol L-1, LDR = 0.1-50 mu mol L-1). Moreover, the mechanism of electrochemical oxidation of GFE was proposed based on calculations of HOMO spatial distribution and spectroelectrochemical measurements focused on IR identification of intermediates and products.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Determination of tramadol in pharmaceutical forms and urine samples using a boron-doped diamond electrode
    Keskin, Ertugrul
    Allahverdiyeva, Shabnam
    Seyho, Esma
    Yardim, Yavuz
    JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2020, 85 (07) : 923 - 937
  • [42] Voltammetric method for sensitive determination of herbicide picloram in environmental and biological samples using boron-doped diamond film electrode
    Bandzuchova, Lenka
    Svorc, Lubomir
    Sochr, Jozef
    Svitkova, Jana
    Chylkova, Jaromira
    ELECTROCHIMICA ACTA, 2013, 111 : 242 - 249
  • [43] Electrochemical determination of nitazoxanide in environmental and pharmaceutical samples using a boron-doped diamond electrode
    Oliveira, Ana Clara M.
    Richter, Eduardo M.
    Paixao, Thiago R. L. C.
    Araujo, Diele A. G.
    Munoz, Rodrigo A. A.
    MICROCHEMICAL JOURNAL, 2024, 207
  • [44] Activated Screen-Printed Boron-Doped Diamond Electrode for Rapid and Highly Sensitive Determination of Curcumin in Food Products
    Kozak, Jedrzej
    Tyszczuk-Rotko, Katarzyna
    Keller, Aleksy
    Wojciak, Magdalena
    Sowa, Ireneusz
    MATERIALS, 2023, 16 (21)
  • [45] A Green Voltammetric Determination of Molnupiravir Using a Disposable Screen-Printed Reduced Graphene Oxide Electrode: Application for Pharmaceutical Dosage and Biological Fluid Forms
    Nabil, Abdelrahman
    Hendawy, Hassan A. M.
    Abdel-Salam, Randa
    Ahmed, Rasha M.
    Shawky, Ahmed
    Emara, Samy
    Ibrahim, Noha
    CHEMOSENSORS, 2023, 11 (09)
  • [46] Effect of Substrate Size on the Electrochemical Properties of Boron-doped Diamond Powders for Screen-printed Diamond Electrode
    Kondo, Takeshi
    Nakajima, Keito
    Osasa, Takahiro
    Kotsugai, Akihiro
    Shitanda, Isao
    Hoshi, Yoshinao
    Itagaki, Masayuki
    Aikawa, Tatsuo
    Tojo, Toshifumi
    Yuasa, Makoto
    CHEMISTRY LETTERS, 2018, 47 (12) : 1464 - 1467
  • [47] Electrochemical study of the antiplatelet agent ticlopidine and its voltammetric determination in pharmaceutical and urine samples using a boron-doped diamond electrode
    Scremin, Jessica
    Karimi-Maleh, Hassan
    Sartori, Elen Romao
    ANALYTICAL METHODS, 2015, 7 (09) : 3750 - 3756
  • [48] Voltammetric determination of caffeine in beverage samples on bare boron-doped diamond electrode
    Svorc, Lubomir
    Tomcik, Peter
    Svitkova, Jana
    Rievaj, Miroslav
    Bustin, Dusan
    FOOD CHEMISTRY, 2012, 135 (03) : 1198 - 1204
  • [49] Flow injection amperometric determination of isoniazid using a screen-printed carbon electrode modified with silver hexacyanoferrates nanoparticles
    de Oliveira, Paulo Roberto
    Oliveira, Marcela Mohallem
    Zarbin, Aldo J. G.
    Marcolino-Junior, Luiz Humberto
    Bergamini, Marcio F.
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 171 : 795 - 802
  • [50] Simultaneous voltammetric determination of acetaminophen and isoniazid using MXene modified screen-printed electrode
    Zhang, Yu
    Jiang, Xiantao
    Zhang, Junjie
    Zhang, Han
    Li, Yingchun
    BIOSENSORS & BIOELECTRONICS, 2019, 130 : 315 - 321