Voltammetric and flow amperometric determination of drug guaifenesin in pharmaceutical and biological samples using screen-printed sensor with boron doped diamond electrode

被引:1
|
作者
Keliskova, Pavlina [1 ]
Matvieiev, Oleksandr [1 ]
Jirouskova, Eliska [2 ]
Sokolova, Romana [2 ]
Janikova, Lenka [1 ]
Behul, Miroslav [3 ]
Selesovska, Renata [1 ]
机构
[1] Univ Pardubice, Inst Environm & Chem Engn, Fac Chem Technol, Studentska 573, Pardubice 53210, Czech Republic
[2] Czech Acad Sci, J Heyrovsky Inst Phys Chem, Dolejskova 3, Prague 18223, Czech Republic
[3] Slovak Univ Technol Bratislava, Inst Elect & Photon, Fac Elect Engn & Informat Technol, Ilkovicova 3, Bratislava 81219, Slovakia
关键词
Guaifenesin; Screen-printed sensor; Boron-doped diamond electrode; Voltammetry; Flow injection analysis with electrochemical detection; Spectroelectrochemistry; MULTIWALLED CARBON NANOTUBE; MASS-SPECTROMETRY METHOD; GAS-CHROMATOGRAPHY; PARACETAMOL; PHENYLEPHRINE; HYDROCHLORIDE; SULFATE; COUGH; SERUM; CELL;
D O I
10.1016/j.talanta.2024.126809
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
New voltammetric and flow amperometric methods for the determination of guaifenesin (GFE) using a perspective screen-printed sensor (SPE) with boron-doped diamond electrode (BDDE) were developed. The electrochemical oxidation of GFE was studied on the surface of the oxygen-terminated BDDE of the sensor. The GFE provided two irreversible anodic signals at a potential of 1.0 and 1.1 V (vs. Ag|AgCl|KCl sat.) in Britton- Robinson buffer (pH 2), which was chosen as the supporting electrolyte for all measurements. First, a voltammetric method based on differential pulse voltammetry was developed and a low detection limit (LOD = 41 nmol L-1), a wide linear dynamic range (LDR = 0.1-155 mu mol L-1), and a good recovery in the analysis of model and pharmaceutical samples (RSD <3.0 %) were obtained. In addition, this sensor demonstrated excellent sensitivity and reproducibility in the analysis of biological samples (RSD <3.2 %), where the analysis took place in a drop of serum (50 mu L) without pretreatment and additional electrolyte. Subsequently, SP/BDDE was incorporated into a flow-through 3D printed electrochemical cell and a flow injection analysis method with electrochemical detection (FIA-ED) was developed, resulting in excellent analytical parameters (LOD = 86 nmol L-1, LDR = 0.1-50 mu mol L-1). Moreover, the mechanism of electrochemical oxidation of GFE was proposed based on calculations of HOMO spatial distribution and spectroelectrochemical measurements focused on IR identification of intermediates and products.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Anodic Voltammetric determination of gemifloxacin using screen-printed carbon electrode
    Radi, Abd-Elgawad
    Khafagy, Amira
    El-shobaky, Amira
    El-mezayen, Hatem
    JOURNAL OF PHARMACEUTICAL ANALYSIS, 2013, 3 (02) : 132 - 136
  • [22] An amperometric method for the determination of cystine in urine samples and pharmaceutical tablets using screen-printed silver electrodes
    Kuo, Fang-Ci
    Huang, Chiung-Yao
    Lin, Yu-Tung
    Tsai, Hwei-yan
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2023, 235
  • [23] Screen-printed gold electrode for ultrasensitive voltammetric determination of the antipsychotic drug thioridazine
    Kozak, Jedrzej
    Tyszczuk-Rotko, Katarzyna
    MEASUREMENT, 2023, 217
  • [24] Determination of prazosin in pharmaceutical samples by flow injection analysis with multiple-pulse amperometric detection using boron-doped diamond electrode
    Guedes, Tiago de Jesus
    Alecrim, Morgana F.
    Oliveira, Fernando M.
    Lima, Amanda B.
    Barbosa, Sandro L.
    dos Santos, Wallans T. P.
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2016, 20 (09) : 2445 - 2451
  • [25] Determination of prazosin in pharmaceutical samples by flow injection analysis with multiple-pulse amperometric detection using boron-doped diamond electrode
    Tiago de Jesus Guedes
    Morgana F. Alecrim
    Fernando M. Oliveira
    Amanda B. Lima
    Sandro L. Barbosa
    Wallans T. P. dos Santos
    Journal of Solid State Electrochemistry, 2016, 20 : 2445 - 2451
  • [26] Voltammetric Determination of Ascorbic Acid in Pharmaceutical Formulations on a Boron Doped Diamond Electrode
    Vedenyapina, M. D.
    Kazakova, M. M.
    Skundin, A. M.
    RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY A, 2019, 93 (06) : 1178 - 1181
  • [27] Voltammetric Determination of Ascorbic Acid in Pharmaceutical Formulations on a Boron Doped Diamond Electrode
    M. D. Vedenyapina
    M. M. Kazakova
    A. M. Skundin
    Russian Journal of Physical Chemistry A, 2019, 93 : 1178 - 1181
  • [28] Voltammetric Determination of Antidepressant Imipramine in Pharmaceutical Preparations Using Boron-Doped Diamond Electrode
    Cinkova, Kristina
    Matokarova, Martina
    Salusova, Ivana
    Plankova, Alexandra
    Brtkova, Barbora
    Borovska, Katarina
    Marton, Marian
    Vojs, Marian
    Svorc, L'ubomir
    CHEMICKE LISTY, 2017, 111 (06): : 392 - 397
  • [29] Novel Screen-Printed Sensor with Chemically Deposited Boron-Doped Diamond Electrode: Preparation, Characterization, and Application
    Matvieiev, Oleksandr
    Selesovska, Renata
    Vojs, Marian
    Marton, Marian
    Michniak, Pavol
    Hrdlicka, Vojtech
    Hatala, Michal
    Janikova, Lenka
    Chylkova, Jaromira
    Skopalova, Jana
    Cankar, Petr
    Navratil, Tomas
    BIOSENSORS-BASEL, 2022, 12 (04):
  • [30] Flow-Injection Amperometric Method for Determination of Diclofenac in Pharmaceutical Formulations Using a Boron-Doped Diamond Electrode
    Gimenes, D. T.
    de Freitas, J. M.
    Munoz, R. A. A.
    Richter, E. M.
    ELECTROANALYSIS, 2011, 23 (11) : 2521 - 2525