Accuracy of intraocular lens power calculation in patients with endothelial dystrophy without edema

被引:0
|
作者
Shemer, Asaf [1 ,2 ]
Fradkin, Maayan [1 ,2 ]
Dubinsky-Pertzov, Biana [1 ,2 ]
Reitblat, Olga [2 ,3 ]
Simaan, Francis [1 ,2 ]
Sella, Ruti [2 ,3 ]
Pras, Eran [1 ,2 ,4 ]
Einan-Lifshitz, Adi [1 ,2 ]
机构
[1] Shamir Med Ctr, Dept Ophthalmol, IL-70300 Zerifin, Israel
[2] Tel Aviv Univ, Fac Med, Tel Aviv, Israel
[3] Rabin Med Ctr, Dept Ophthalmol, Petah Tiqwa, Israel
[4] Shamir Med Ctr, Dept Ophthalmol, Matlows Ophthalmo Genet Lab, Zerifin, Israel
来源
关键词
REFRACTIVE OUTCOMES; CATARACT-SURGERY; KERATOPLASTY;
D O I
10.1097/j.jcrs.0000000000001578
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the accuracy of several intraocular lens (IOL) formulas for patients with endothelial dystrophy (ED) without edema treated with cataract surgery alone. Setting: 1 academic, tertiary referral center. Design: Comparative retrospective cohort study. Methods: The predicted refractive results of patients with ED who underwent cataract surgery were assessed and compared with a matched control group. The accuracy of 5 different IOL formulas, Haigis, Holladay 1, Barrett Universal II (BUII), SRK/T, and Kane, was evaluated and compared between the groups. The SDs of the prediction error (PE) of all formulas were compared. Results:221 eyes were included in this study. 50 (23%) eyes of patients with ED and 171 (77%) control eyes. There was no significant difference between the 2 groups in clinical and demographical characteristics (P > .05). The postoperative spherical equivalent was -0.37 diopters (D) in the ED group and -0.30 D in the control group (P = .8). Overall, both groups had a comparable SD of the PE and absolute PE in all formulas (P > .05). In the ED group, absolute PE was 0.34 D for Haigis, 0.32 D for Holladay 1, 0.32 D for BUII, 0.38 D for SRK/T, and 0.32 D for Kane formulas. No statistically significant difference between formulas was found. Conclusions: The prediction accuracy of IOL power calculation in patients with ED was found comparable both between formulas and in comparison with healthy controls. This suggests that in patients with guttate without edema, the IOL power calculations are as effective and accurate as in healthy eyes.
引用
收藏
页码:141 / 146
页数:6
相关论文
共 50 条
  • [11] Accuracy of Ten Intraocular Lens Formulas in Spherical Equivalent of Toric Intraocular Lens Power Calculation
    Shi, Jingyi
    Zhu, Zehui
    Hu, Bin
    Qian, Shuyi
    Wang, Yalan
    Chang, Pingjun
    Zhao, Yun-e
    OPHTHALMOLOGY AND THERAPY, 2024, 13 (05) : 1321 - 1342
  • [12] Intraocular lens power calculation in phacovitrectomy patients
    Partwardhan, Ashish A.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (04): : 529 - 529
  • [13] Evaluation of the Accuracy of Intraocular Lens Power Calculation Formulas in Phacovitrectomy
    Tanaka, Yuichiro
    Kamiya, Kazutaka
    Igarahi, Akihito
    Shoji, Nobuyuki
    Tsuchiya, Hiroshi
    Takahashi, Shinya
    Ishikawa, Eri
    Kozawa, Tadahiko
    OPHTHALMOLOGY AND THERAPY, 2024, 13 (08) : 2197 - 2208
  • [14] Accuracy of Intraocular lens power calculation in pediatric traumatic cataract
    Goyal, Priya
    Tibrewal, Shailja
    Ganesh, Suma
    Rath, Soveeta
    Majumdar, Atanu
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2024, 72 (11) : 1605 - 1610
  • [15] Comparison of the accuracy of 11 intraocular lens power calculation formulas
    Carmona-Gonzalez, David
    Castillo-Gomez, Alfredo
    Palomino-Bautista, Carlos
    Romero-Dominguez, Marta
    Gutierrez-Moreno, Maria Angeles
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (05) : 2370 - 2376
  • [16] Improved accuracy of intraocular lens power calculation with the Zeiss IOLMaster
    Olsen, Thomas
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2007, 85 (01): : 84 - 87
  • [17] Accuracy of intraocular lens power calculation in paediatric cataract surgery
    Tromans, C
    Haigh, PM
    Biswas, S
    Lloyd, IC
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (08) : 939 - 941
  • [18] Accuracy of New Intraocular Lens Power Calculation Formulas: A Lens Thickness Study
    Taroni, Leonardo
    Hoffer, Kenneth J.
    Lupardi, Enrico
    Barboni, Piero
    Savini, Giacomo
    JOURNAL OF REFRACTIVE SURGERY, 2021, 37 (03) : 202 - 206
  • [19] Accuracy of newer generation intraocular lens power calculation formulas in pediatric cataract patients
    Lin, Lei
    Fang, Jiayan
    Sun, Weijie
    Gu, Siyi
    Xu, Liming
    Chen, Siping
    Chang, Pingjun
    Zhao, Yun-e
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2023, 261 (04) : 1019 - 1027
  • [20] Accuracy of newer generation intraocular lens power calculation formulas in pediatric cataract patients
    Lei Lin
    Jiayan Fang
    Weijie Sun
    Siyi Gu
    Liming Xu
    Siping Chen
    Pingjun Chang
    Yun-e Zhao
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2023, 261 : 1019 - 1027