A New Pilot Hole Preparation System for Percutaneous Pedicle Screw Placement A Randomized Controlled Study

被引:0
|
作者
Feng, Chaobo [1 ,2 ,3 ]
Wang, Longfei [1 ]
Yang, Sheng [1 ]
Wu, Xinbo [1 ]
Fan, Yunshan [1 ]
Yan, Huang [1 ]
Chen, Fangjing [1 ]
Chen, Jia [1 ]
Wang, Xiang [1 ]
Guo, Qishuai [1 ]
Yao, Longxiang [1 ]
Zhao, Yingchuan [1 ]
He, Shisheng [1 ]
Ni, Haijian [1 ]
机构
[1] Tongji Univ, Shanghai Peoples Hosp 10, Spinal Pain Res Inst, Dept Orthoped,Sch Med, Shanghai 200072, Peoples R China
[2] Shenzhen Univ, Sch Biomed Engn, Guangdong Key Lab Biomed Measurements & Ultrasound, Natl Reg Key Technol Engn Lab Med Ultrasound,Med S, Shenzhen, Peoples R China
[3] Huazhong Univ Sci & Technol, Dept Pain Med, Union Shenzhen Hosp, Shenzhen, Peoples R China
关键词
lumbar interbody fusion; minimally invasive spine surgery; percutaneous pedicle screw; pilot hole; RADIATION-EXPOSURE; ACCURACY; TIME;
D O I
10.1097/BRS.0000000000005184
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. A randomized controlled study. Objective. To introduce a new pilot hole preparation system for percutaneous pedicle screw placement and investigate its efficiency and safety in comparison with the conventional method. Summary of Background Data. Placing screws accurately, rapidly, and safely with less radiation exposure is critical for minimally invasive lumbar interbody fusion (LIF). Optimizing pilot hole preparation instruments has important clinical implications. Materials and Methods. A total of 60 patients (180 screws) were included in this study. All patients were randomized into two groups (new system vs. conventional method) and performed single-level minimally invasive percutaneous fixation, interbody fusion, and unilateral decompression. Basic information, time of pilot hole preparation, time of screw placement, and fluoroscopy time were recorded. Screw placement accuracy was graded based on the Gertzbein-Robbins scale, and the angle between the screw axis and the pedicle axis was collected in postoperative CT. Results. There was no statistical difference in basic information between the 2 groups. The mean time of single pilot hole preparation was 4.08 +/- 1.01 minutes in the new system group and 5.34 +/- 1.30 minutes in the conventional method group (P<0.001). The time of single screw placement was significantly shorter in the new system group (0.82 +/- 0.20 vs. 1.72 +/- 0.33 min), and the fluoroscopy time was also less in the new system group (13.70 +/- 3.42 vs. 19.95 +/- 5.50 s) (P<0.001). Screw placement accuracy assessment showed that there were 85 (94.45%) A-grade screws in the new system group while 76 (84.44%) A-grade screws in the conventional method group (P=0.027). Conclusions. The new pilot hole preparation system has shown significant reductions in the time of pilot hole preparation, time of screw placement, and radiation exposure, and has good clinical application value.
引用
收藏
页码:115 / 121
页数:7
相关论文
共 50 条
  • [41] A Novel Pedicle Screw with Mobile Connection: A Pilot Study
    Tokuhashi, Yasuaki
    Oshima, Masashi
    Ajiro, Yasumitsu
    Uei, Hiroshi
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [42] Percutaneous Placement of Pedicle Screws in the Lumbar Spine Using a Bone Mounted Miniature Robotic System First Experiences and Accuracy of Screw Placement
    Pechlivanis, Ioannis
    Kiriyanthan, George
    Engelhardt, Martin
    Scholz, Martin
    Luecke, Sebastian
    Harders, Albrecht
    Schmieder, Kirsten
    SPINE, 2009, 34 (04) : 392 - 398
  • [43] Augmented Reality Navigation System Enhances the Accuracy of Spinal Surgery Pedicle Screw Placement: A Randomized, Multicenter, Parallel-Controlled Clinical Trial
    Ma, Yichao
    Wu, Jiangpeng
    Dong, Yanlong
    Tang, Hongmei
    Ma, Xiaojun
    ORTHOPAEDIC SURGERY, 2025, 17 (02) : 631 - 643
  • [44] Augmented reality navigated pedicle screw placement - a cadaveric study
    Spirig, Jose
    Roner, Simon
    Liebmann, Florentin
    Furnstahl, Philipp
    Farshad, Mazda
    SWISS MEDICAL WEEKLY, 2019, 149 : 20S - 20S
  • [45] Learning Curve for Robot-Assisted Percutaneous Pedicle Screw Placement in Thoracolumbar Surgery
    Kam, Jeremy K. T.
    Gan, Calvin
    Dimou, Stefan
    Awad, Mohammed
    Kavar, Bhadu
    Nair, Girish
    Morokoff, Andrew
    ASIAN SPINE JOURNAL, 2019, 13 (06) : 920 - 927
  • [46] A Novel Retractor for Reducing Operation Time and Radiation Exposure in Percutaneous Pedicle Screw Placement
    Niu, Lei
    He, Rui
    Duan, Liqun
    Zhang, Wenzhi
    Li, Xu
    Cai, Haiping
    TURKISH NEUROSURGERY, 2021, 31 (04) : 538 - 544
  • [47] Percutaneous pedicle screw placement with computer-navigated mapping in place of Kirschner wires
    Gianaris, Thomas J.
    Helbig, Gregory M.
    Horn, Eric M.
    JOURNAL OF NEUROSURGERY-SPINE, 2013, 19 (05) : 608 - 613
  • [48] Percutaneous pedicle screw placement into a spinal segment previously treated with vertebroplasty: technical note
    Gernsback, Joanna E.
    Wang, Michael Y.
    JOURNAL OF NEUROSURGERY-SPINE, 2016, 24 (05) : 786 - 791
  • [49] Accuracy of Robot-Assisted Percutaneous Pedicle Screw Placement for Treatment of Lumbar Spondylolisthesis: A Comparative Cohort Study
    Yang, Jun-Song
    He, Baorong
    Tian, Fang
    Liu, Tuan-Jiang
    Liu, Peng
    Zhang, Jia-Nan
    Liu, Shi-Chang
    Tuo, Yuan
    Chu, Lei
    Hao, Ding-Jun
    MEDICAL SCIENCE MONITOR, 2019, 25 : 2479 - 2487
  • [50] Accuracy of Robot-Assisted Percutaneous Pedicle Screw Placement under Regional Anesthesia: A Retrospective Cohort Study
    Gao, Shangju
    Wei, Jingchao
    Li, Wenyi
    Zhang, Long
    Cao, Can
    Zhai, Jinshuai
    Gao, Bo
    PAIN RESEARCH & MANAGEMENT, 2021, 2021