Energy saving and performance assessment of a split-type air conditioner integrated by an evaporative cooling unit with nanofluids

被引:0
|
作者
Elsaid, Ashraf Mimi [1 ]
Wahba, M. A. I. [2 ]
Sharshir, Swellam W. [3 ]
Abd Raboo, M. F. [4 ]
机构
[1] Helwan Univ, Fac Technol & Educ, Refrigerat & Air Conditioning Technol Dept, POB 11282, Cairo, Egypt
[2] Benha Univ, Fac Engn Shoubra, Basic Sci Dept, Cairo, Egypt
[3] Kafrelsheikh Univ, Fac Engn, Mech Engn Dept, Kafrelsheikh, Egypt
[4] Benha Univ, Fac Engn Shoubra, Mech Dept, Cairo, Egypt
关键词
Air conditioning system; Energy saving; Evaporative cooling; Economic Feasibility; Coefficient of performance; Hybrid nanofluids; CONVECTIVE HEAT-TRANSFER; COILED FINNED TUBE; THERMAL-CONDUCTIVITY; COOLED CONDENSER; HYBRID NANOFLUID; CROSS-FLOW; WATER; SYSTEM; OPTIMIZATION; THICKNESS;
D O I
10.1016/j.applthermaleng.2024.125178
中图分类号
O414.1 [热力学];
学科分类号
摘要
Temperatures inside inhabited buildings rise at an increasing rate during the summer, which leads to the urgent need for air conditioners. At the same time, their performance decreases during the peak summer period, which leads to a loss of thermal comfort, and energy consumption increases accordingly. Therefore, it is necessary to inspect ways to enhance the thermal performance of air conditioners considering high external temperatures to restore air conditioning performance and minimize energy consumption. This research was directed to experimentally evaluate a split air conditioning device for cooling mode with an evaporative cooling unit (ECU) employing single and hybrid nanomaterials. Four types of evaporative cooling pads were examined: aspen wood wool, honeycomb paper, coconut fiber, and plastic sponge. An ultrasonic atomizer was utilized as a mist maker to energize the air-cooling process. Four different diameters of spray nozzles were tested for the evaporative cooling unit: 0.2, 0.3, 0.4, and 0.5 mm. Two types of TiO2 and MgO nanomaterials were used by weight ratios of 0.25, 0.5, 0.75, and 1%, in addition to the hybridization between them, TiO2/MgO, in equal mixing ratios of 50/50%. The crucial results reflected that the wood wool cooling pad provides a higher performance index and EER than other types. Higher COP is obtained with a hybrid TiO2+MgO/H2O by approximately 15.8%. The overall energy savings rise when considering MgO+TiO2/H2O instead of MgO/H2O and TiO2/H2O. The ECU combined with the mini split A/C achieves the highest COP compared to the traditional A/C device by 35.9% and recovers its initial cost within 4.7 years with the hybrid nanomaterials. Using the MgO+TiO2/H2O mixture, the net life-cycle cost saving is US$ 430.16. Multiple nonlinear regression methods were used to propose a mathematical model for COP. The Adjusted R2 is about 0.964287, and the root mean square error value is about 0.1717628, indicating the prediction model's accuracy and reliability.
引用
收藏
页数:24
相关论文
共 50 条
  • [31] An Influence of Air Volume Flow Rate and Temperature Set Point on Performance of Inverter Split-Type Air-Conditioner
    Rachapradit, N.
    Thepa, S.
    Monyakulb, V.
    EXPERIMENTAL TECHNIQUES, 2012, 36 (04) : 18 - 25
  • [32] An influence of air volume flow rate and temperature set point on performance of inverter split-type air-conditioner
    N. Rachapradit
    S. Thepa
    V. Monyakulb
    Experimental Techniques, 2012, 36 : 18 - 25
  • [33] Evaluation of the impact of installation environment for a condensing unit of a split-type air conditioner in a plant room of Korean apartment dwellings
    Kwag, Byung Chang
    Kim, Gil Tae
    Im, Dongkyun
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 156 : 207 - 218
  • [34] Energy Saving Assessment of Evaporative Cooling HVDC Valves
    Huang, Wei
    Feng, Wei
    Guo, Jianghong
    Wang, Haifeng
    INTERNATIONAL CONFERENCE ON ELECTRICAL AND CONTROL ENGINEERING (ICECE 2015), 2015, : 288 - 291
  • [35] Power Baseline Modeling for Split-Type Air Conditioner in Building Energy Management Systems Using Deep Learning
    Chumnanvanichkut, Pornpra
    Chirapongsananurak, Pisitpol
    Hooncliarcon, Naehhoon
    2019 IEEE ASIA PACIFIC CONFERENCE ON CIRCUITS AND SYSTEMS (APCCAS 2019), 2019, : 198 - 201
  • [36] Energy reduction of split-type air conditioners using a pre-cooling system for the condenser
    Thiangchanta, Surasit
    Do, Tuan Anh
    Suttakul, Pana
    Mona, Yuttana
    ENERGY REPORTS, 2021, 7 (07) : 1 - 6
  • [37] Design and implementation of an intelligent controller for a split air conditioner with energy saving
    Ahilan, C.
    Kumanan, S.
    Sivakumaran, N.
    Advances in Modelling and Analysis C, 2010, 65 (1-2): : 21 - 40
  • [38] Experimental evaluation on a centralized air conditioning system embedded with a split-type air conditioner as a dedicated subcooler
    Sumeru, Kasni
    Sukri, Mohamad Firdaus
    Pramudantoro, Triaji Pangripto
    Erham, Eddy
    Muliawan, Rizki
    JOURNAL OF BUILDING ENGINEERING, 2021, 43
  • [39] Experimental study on the performance of a novel data center air conditioner combining air cooling and evaporative cooling
    Zhang, Yaxi
    Han, Haixiao
    Zhang, Yanqiu
    Li, Jun
    Zheng, Yao
    Liu, Changxiong
    Liu, Yubo
    Gao, Diance
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2025, 170 : 98 - 112
  • [40] Modeling of a split type air conditioner with integrated water heater
    Techarungpaisan, P.
    Theerakulpisut, S.
    Priprem, S.
    ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (04) : 1222 - 1237