Energy saving and performance assessment of a split-type air conditioner integrated by an evaporative cooling unit with nanofluids

被引:0
|
作者
Elsaid, Ashraf Mimi [1 ]
Wahba, M. A. I. [2 ]
Sharshir, Swellam W. [3 ]
Abd Raboo, M. F. [4 ]
机构
[1] Helwan Univ, Fac Technol & Educ, Refrigerat & Air Conditioning Technol Dept, POB 11282, Cairo, Egypt
[2] Benha Univ, Fac Engn Shoubra, Basic Sci Dept, Cairo, Egypt
[3] Kafrelsheikh Univ, Fac Engn, Mech Engn Dept, Kafrelsheikh, Egypt
[4] Benha Univ, Fac Engn Shoubra, Mech Dept, Cairo, Egypt
关键词
Air conditioning system; Energy saving; Evaporative cooling; Economic Feasibility; Coefficient of performance; Hybrid nanofluids; CONVECTIVE HEAT-TRANSFER; COILED FINNED TUBE; THERMAL-CONDUCTIVITY; COOLED CONDENSER; HYBRID NANOFLUID; CROSS-FLOW; WATER; SYSTEM; OPTIMIZATION; THICKNESS;
D O I
10.1016/j.applthermaleng.2024.125178
中图分类号
O414.1 [热力学];
学科分类号
摘要
Temperatures inside inhabited buildings rise at an increasing rate during the summer, which leads to the urgent need for air conditioners. At the same time, their performance decreases during the peak summer period, which leads to a loss of thermal comfort, and energy consumption increases accordingly. Therefore, it is necessary to inspect ways to enhance the thermal performance of air conditioners considering high external temperatures to restore air conditioning performance and minimize energy consumption. This research was directed to experimentally evaluate a split air conditioning device for cooling mode with an evaporative cooling unit (ECU) employing single and hybrid nanomaterials. Four types of evaporative cooling pads were examined: aspen wood wool, honeycomb paper, coconut fiber, and plastic sponge. An ultrasonic atomizer was utilized as a mist maker to energize the air-cooling process. Four different diameters of spray nozzles were tested for the evaporative cooling unit: 0.2, 0.3, 0.4, and 0.5 mm. Two types of TiO2 and MgO nanomaterials were used by weight ratios of 0.25, 0.5, 0.75, and 1%, in addition to the hybridization between them, TiO2/MgO, in equal mixing ratios of 50/50%. The crucial results reflected that the wood wool cooling pad provides a higher performance index and EER than other types. Higher COP is obtained with a hybrid TiO2+MgO/H2O by approximately 15.8%. The overall energy savings rise when considering MgO+TiO2/H2O instead of MgO/H2O and TiO2/H2O. The ECU combined with the mini split A/C achieves the highest COP compared to the traditional A/C device by 35.9% and recovers its initial cost within 4.7 years with the hybrid nanomaterials. Using the MgO+TiO2/H2O mixture, the net life-cycle cost saving is US$ 430.16. Multiple nonlinear regression methods were used to propose a mathematical model for COP. The Adjusted R2 is about 0.964287, and the root mean square error value is about 0.1717628, indicating the prediction model's accuracy and reliability.
引用
收藏
页数:24
相关论文
共 50 条
  • [21] Theoretical performance analysis of window air conditioner combined with evaporative cooling for better indoor thermal comfort and energy saving
    Dhamneya, Amrat Kumar
    Rajput, S. P. S.
    Singh, Alok
    JOURNAL OF BUILDING ENGINEERING, 2018, 17 : 52 - 64
  • [22] Experimental implementation of a split-type air conditioner for fault detection and diagnosis
    Bilgili, Mehmet
    Teke, Ahmet
    Yasar, Abdulkadir
    Simsek, Erdogan
    ENERGY EDUCATION SCIENCE AND TECHNOLOGY PART A-ENERGY SCIENCE AND RESEARCH, 2011, 28 (01): : 401 - 410
  • [23] Numerical and experimental study of an ejector as an expansion device in split-type air conditioner for energy savings
    Sumeru, Kasni
    Sulaimon, Shodiya
    Nasution, Henry
    Anid, Farid Nasir
    ENERGY AND BUILDINGS, 2014, 79 : 98 - 105
  • [24] On similitude of the cross flow fan in a split-type air-conditioner
    Shih, Yang-Cheng
    Hou, Hung-Chi
    Chiang, Hsucheng
    APPLIED THERMAL ENGINEERING, 2008, 28 (14-15) : 1853 - 1864
  • [25] Numerical Study of Ejector as an Expansion Device in Split-type Air Conditioner
    Sumeru, Kasni
    Nasution, Henry
    Ani, Farid Nasir
    ADVANCES IN THERMOFLUIDS, 2013, 388 : 101 - 105
  • [26] Experimental study on energy performance of a split air-conditioner by using variable thickness evaporative cooling pads coupled to the condenser
    Martinez, P.
    Ruiz, J.
    Cutillas, C. G.
    Martinez, P. J.
    Kaiser, A. S.
    Lucas, M.
    APPLIED THERMAL ENGINEERING, 2016, 105 : 1041 - 1050
  • [27] Thermohydraulic and condensing phase-change analysis within the indoor unit of a split-type air-conditioner
    Tsao, Chung-Chun
    Shih, Yang-Cheng
    Lin, Chun-Hsiung
    Chao, Ling-Yu
    Hu, Shih-Cheng
    CASE STUDIES IN THERMAL ENGINEERING, 2020, 21
  • [28] Comprehensive study of the impacts of surrounding structures on the aero-dynamic performance and flow characteristics of an outdoor unit of split-type air conditioner
    Mehryan, S. A. M.
    Kashkooli, Farshad M.
    Soltani, M.
    BUILDING SIMULATION, 2018, 11 (02) : 325 - 337
  • [29] Comprehensive study of the impacts of surrounding structures on the aero-dynamic performance and flow characteristics of an outdoor unit of split-type air conditioner
    S. A. M. Mehryan
    Farshad M. Kashkooli
    M. Soltani
    Building Simulation, 2018, 11 : 325 - 337
  • [30] Performance of a clothes drying cabinet by utilizing waste heat from a split-type residential air conditioner
    Ambarita, Himsar
    Nasution, Abdul Halim
    Siahaan, Nelson M.
    Kawai, Hideki
    CASE STUDIES IN THERMAL ENGINEERING, 2016, 8 : 105 - 114