Non-Surgical, In-Stent Membrane Bioelectronics for Long-Term Intracranial Pressure Monitoring

被引:0
|
作者
Lee, Jimin [1 ,2 ]
Bateman, Allison [1 ,2 ]
Kim, Mi Hyeon [3 ,4 ]
Rigo, Bruno [2 ,5 ]
Kim, Hodam [1 ,6 ]
Lee, Jaeho [1 ,2 ]
Choi, Yun Hyeok [7 ]
Herbert, Robert [8 ]
Lee, Deok Hee [3 ]
Yeo, Woon-Hong [1 ,2 ,9 ,10 ,11 ]
机构
[1] Georgia Inst Technol, George W Woodruff Sch Mech Engn, Atlanta, GA 30332 USA
[2] Georgia Inst Technol, Wearable Intelligent Syst & Healthcare Ctr, Inst Matter & Syst, Atlanta, GA 30332 USA
[3] Univ Ulsan, Res Inst Radiol, Asan Med Ctr, Dept Radiol,Coll Med, 88 Olymp Ro,43 Gil, Seoul 05505, South Korea
[4] Asan Med Ctr, Asan Inst Life Sci, Biomed Engn Res Ctr, 88 Olymp Ro,43 Gil, Seoul 05505, South Korea
[5] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
[6] Icahn Sch Med Mt Sinai, Biomed Engn & Imaging Inst, New York, NY 10029 USA
[7] Inje Univ, Haeundae Paik Hosp, 875 Haeun Daero, Busan 48108, South Korea
[8] Louisiana State Univ, Dept Mech & Ind Engn, Baton Rouge, LA 70803 USA
[9] Georgia Inst Technol, Wallace H Coulter Dept Biomed Engn, Atlanta, GA 30332 USA
[10] Emory Univ, Sch Med, Atlanta, GA 30332 USA
[11] Georgia Inst Technol, Parker H Petit Inst Bioengn & Biosci, Atlanta, GA 30332 USA
基金
美国国家科学基金会;
关键词
capacitive sensors; endovascular stent; intracranial pressure; minimally invasive; porous pyramidal structure; WIRELESS; SENSOR; MORTALITY;
D O I
10.1002/adhm.202404680
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Traditional intracranial pressure (ICP) monitoring methods, using intraventricular catheters, face significant limitations, including high invasiveness, discrete data, calibration complexities, and drift issues, which hinder long-term and stable monitoring. Here, a non-surgical, in-stent membrane bioelectronic system is presented for continuous and reliable ICP monitoring. This platform integrates a capacitive thin-film sensor with a stent, enabling precise real-time detection of pressure fluctuations directly within the dural venous sinus without requiring skull penetration or frequent recalibration. The sensor demonstrates a high sensitivity of 0.052%/mmHg and a broad, readable pressure range of 3-30 mmHg while maintaining calibration-free and drift-free performance. A series of in vivo studies highlight the system's superior sensitivity, rapid sampling rate, and long-term stability compared to conventional microcatheters. Statistical analyses reveal a strong agreement between the device and clinical reference, underscoring its potential to revolutionize ICP monitoring. These advancements pave the way for broader clinical applications, minimizing complications and improving patient outcomes in neurocritical care.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Long-term outcome of non-surgical root canal treatment: a retrospective analysis
    Chiara Pirani
    Stefano Chersoni
    Lucio Montebugnoli
    Carlo Prati
    Odontology, 2015, 103 : 185 - 193
  • [32] Long-Term Stability of Er:YAG Laser Non-Surgical Periodontal Treatment
    Yaneva, Blagovesta
    Tomov, Georgi
    Karaslavova, Emiliya
    Romanos, Georgios E.
    APPLIED SCIENCES-BASEL, 2023, 13 (21):
  • [33] Initial outcome and long-term effect of surgical and non-surgical treatment of advanced periodontal disease
    Serino, G
    Rosling, B
    Ramberg, P
    Socransky, SS
    Lindhe, J
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2001, 28 (10) : 910 - 916
  • [34] Long-term telemetric intracranial pressure monitoring for diagnosis and therapy optimisation of idiopathic intracranial hypertension
    Velazquez Sanchez, Victor F.
    Al Dayri, Giath
    Tschan, Christoph A.
    BMC NEUROLOGY, 2021, 21 (01)
  • [35] Long-term telemetric intracranial pressure monitoring for diagnosis and therapy optimisation of idiopathic intracranial hypertension
    Victor F. Velazquez Sanchez
    Giath Al Dayri
    Christoph A. Tschan
    BMC Neurology, 21
  • [36] Long-term efficacy of intracoronary irradiation in inhibiting in-stent restenosis
    Brenner, DJ
    Miller, RC
    CIRCULATION, 2001, 103 (09) : 1330 - 1332
  • [37] Lipoprotein(a) in clinical practice: The role in long-term in-stent restenosis
    Sbrana, Francesco
    Dal Pino, Beatrice
    JOURNAL OF CLINICAL LIPIDOLOGY, 2025, 19 (01) : 188 - 189
  • [38] Wirelessly Powered Implantable System for Wireless Long-Term Monitoring of Intracranial Pressure
    Khan, M. Waqas A.
    Sydanheimo, Lauri
    Bjorninen, Toni
    Ukkonen, Leena
    2017 INTERNATIONAL WORKSHOP ON ANTENNA TECHNOLOGY: SMALL ANTENNAS, INNOVATIVE STRUCTURES, AND APPLICATIONS (IWAT), 2017, : 122 - 124
  • [39] Modification of subdural catheters for long-term intracranial pressure monitoring of conscious rabbits
    Storrow, AB
    Hoxie, N
    CONTEMPORARY TOPICS IN LABORATORY ANIMAL SCIENCE, 1998, 37 (03): : 62 - 65
  • [40] LONG-TERM PERFORMANCE OF A CE-APPROVED TELEMETRIC INTRACRANIAL PRESSURE MONITORING
    Kiefer, Michael
    Antes, Sebastian
    Schmitt, Melanie
    Krause, Inga
    Eymann, Regina
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 2246 - 2249