Non-Surgical, In-Stent Membrane Bioelectronics for Long-Term Intracranial Pressure Monitoring

被引:0
|
作者
Lee, Jimin [1 ,2 ]
Bateman, Allison [1 ,2 ]
Kim, Mi Hyeon [3 ,4 ]
Rigo, Bruno [2 ,5 ]
Kim, Hodam [1 ,6 ]
Lee, Jaeho [1 ,2 ]
Choi, Yun Hyeok [7 ]
Herbert, Robert [8 ]
Lee, Deok Hee [3 ]
Yeo, Woon-Hong [1 ,2 ,9 ,10 ,11 ]
机构
[1] Georgia Inst Technol, George W Woodruff Sch Mech Engn, Atlanta, GA 30332 USA
[2] Georgia Inst Technol, Wearable Intelligent Syst & Healthcare Ctr, Inst Matter & Syst, Atlanta, GA 30332 USA
[3] Univ Ulsan, Res Inst Radiol, Asan Med Ctr, Dept Radiol,Coll Med, 88 Olymp Ro,43 Gil, Seoul 05505, South Korea
[4] Asan Med Ctr, Asan Inst Life Sci, Biomed Engn Res Ctr, 88 Olymp Ro,43 Gil, Seoul 05505, South Korea
[5] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30332 USA
[6] Icahn Sch Med Mt Sinai, Biomed Engn & Imaging Inst, New York, NY 10029 USA
[7] Inje Univ, Haeundae Paik Hosp, 875 Haeun Daero, Busan 48108, South Korea
[8] Louisiana State Univ, Dept Mech & Ind Engn, Baton Rouge, LA 70803 USA
[9] Georgia Inst Technol, Wallace H Coulter Dept Biomed Engn, Atlanta, GA 30332 USA
[10] Emory Univ, Sch Med, Atlanta, GA 30332 USA
[11] Georgia Inst Technol, Parker H Petit Inst Bioengn & Biosci, Atlanta, GA 30332 USA
基金
美国国家科学基金会;
关键词
capacitive sensors; endovascular stent; intracranial pressure; minimally invasive; porous pyramidal structure; WIRELESS; SENSOR; MORTALITY;
D O I
10.1002/adhm.202404680
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Traditional intracranial pressure (ICP) monitoring methods, using intraventricular catheters, face significant limitations, including high invasiveness, discrete data, calibration complexities, and drift issues, which hinder long-term and stable monitoring. Here, a non-surgical, in-stent membrane bioelectronic system is presented for continuous and reliable ICP monitoring. This platform integrates a capacitive thin-film sensor with a stent, enabling precise real-time detection of pressure fluctuations directly within the dural venous sinus without requiring skull penetration or frequent recalibration. The sensor demonstrates a high sensitivity of 0.052%/mmHg and a broad, readable pressure range of 3-30 mmHg while maintaining calibration-free and drift-free performance. A series of in vivo studies highlight the system's superior sensitivity, rapid sampling rate, and long-term stability compared to conventional microcatheters. Statistical analyses reveal a strong agreement between the device and clinical reference, underscoring its potential to revolutionize ICP monitoring. These advancements pave the way for broader clinical applications, minimizing complications and improving patient outcomes in neurocritical care.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Telemetric Implantable pressure sensor for short- and long-term monitoring of intracranial pressure
    Frischholz, M.
    Sarmento, L.
    Wenzel, M.
    Aquilina, K.
    Edwards, R.
    Coakham, H. B.
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 514 - +
  • [22] Long-term monitoring of intracranial pressure in normal pressure hydrocephalus and other CSF disorders
    Zofia Czosnyka
    Marek Czosnyka
    Acta Neurochirurgica, 2017, 159 : 1979 - 1980
  • [23] Long-term outcome of non-surgical root canal treatment: a retrospective analysis
    Pirani, Chiara
    Chersoni, Stefano
    Montebugnoli, Lucio
    Prati, Carlo
    ODONTOLOGY, 2015, 103 (02) : 185 - 193
  • [24] Long-term non-surgical therapy of severe persistent congenital hyperinsulinism with glucagon
    Mohnike, K.
    Blankenstein, O.
    Pfuetzner, A.
    Poetzsch, S.
    Schober, E.
    Steiner, S.
    Hardy, O. T.
    Grimberg, A.
    van Waarde, W. M.
    HORMONE RESEARCH, 2008, 70 (01) : 59 - 64
  • [25] Long-term monitoring of intracranial pressure in normal pressure hydrocephalus and other CSF disorders
    Czosnyka, Zofia
    Czosnyka, Marek
    ACTA NEUROCHIRURGICA, 2017, 159 (10) : 1979 - 1980
  • [26] Long-term outcomes of acute acalculous cholecystitis treated by non-surgical management
    Kim, Sung Bum
    Gu, Min Geun
    Kim, Kook Hyun
    Kim, Tae Nyeun
    MEDICINE, 2020, 99 (07)
  • [27] Non-surgical closure of patent ductus arteriosus: acute and long-term results
    Chatterjee, T
    Windecker, S
    Pfammatter, JP
    Seiler, C
    Meier, B
    SCHWEIZERISCHE MEDIZINISCHE WOCHENSCHRIFT, 2000, 130 (18) : 664 - 670
  • [28] LONG-TERM EVALUATION OF NON-SURGICAL TREATMENT OF OSTEOARTHROSIS OF THE TEMPOROMANDIBULAR-JOINT
    YOSHIMURA, Y
    YOSHIDA, Y
    OKA, M
    MIYOSHI, M
    UEMURA, S
    INTERNATIONAL JOURNAL OF ORAL SURGERY, 1982, 11 (01): : 7 - 13
  • [29] ACUTE INFLAMMATION AND LONG-TERM MORTALITY IN NON-SURGICAL INTENSIVE CARE PATIENTS
    Grander, W.
    Duenser, M. W.
    Dengg, C.
    Koller, B.
    Eller, P.
    Tilg, H.
    INTENSIVE CARE MEDICINE, 2009, 35 : 85 - 85
  • [30] Methodological Challenges in Evaluating Long-Term Safety of Quinacrine Non-Surgical Sterilization
    Li, Jie
    Jones, Judith K.
    Tave, Arlene
    Pezzullo, John C.
    PHARMACOEPIDEMIOLOGY AND DRUG SAFETY, 2010, 19 : S299 - S299