Corrosion Assessment in Reinforced Concrete Structures by Means of Embedded Sensors and Multivariate Analysis-Part 2: Implementation

被引:0
|
作者
Lliso-Ferrando, Josep Ramon [1 ,2 ]
Martinez-Ibernon, Ana [1 ,2 ]
Ramon-Zamora, Jose Enrique [3 ]
Gandia-Romero, Jose Manuel [1 ,2 ]
机构
[1] Univ Politecn Valencia, Res Inst Mol Recognit & Technol Dev IDM, Camino Vera S-N, Valencia 46022, Spain
[2] Univ Politecn Valencia, Sch Architecture, Dept Architectural Construct, Camino Vera S-N, Valencia 46022, Spain
[3] CSIC, Inst Ciencias Construcc Eduardo Torroja, C Serrano Galvache 4, Madrid 28002, Spain
来源
APPLIED SCIENCES-BASEL | 2024年 / 14卷 / 19期
关键词
reinforced concrete structures; corrosion; structural health monitoring; structural management; sensors; remote sensing; corrosion monitoring; multivariate analysis; SERVICE LIFE PREDICTION; STEEL; INFRASTRUCTURE; QUESTIONS; CURRENTS;
D O I
10.3390/app14199002
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The economic cost of repairing corrosion-affected reinforced concrete structures (RCSs) means that reliable and accurate assessment and early detection methods must be sought after. Conventional techniques, such as visual inspections, or measuring either cover layer resistivity or the corrosion potential, are methods that require accessibility and involve personnel having to travel to take in situ measurements. Monitoring by embedded sensors is a much more efficient approach that allows early detection by remote sensing. This work presents the implementation of a new measurement protocol regarding the existing monitoring system called INESSCOM (Integrated Sensor Network for Smart Corrosion Monitoring). Along with the corrosion intensity measurement in embedded sensors, it also proposes monitoring the double layer capacity of the sensors' responses. It aims to determine, along with the rebars' corrosion rate, the triggering agent of the corrosion process. This study was carried out using three reinforced concrete scaled columns that were exposed to different environments. The results demonstrate with this new protocol that the remote INESSCOM monitoring system can establish the corrosion rate and identify the precursor agent of corrosion (carbonation or chlorides), even when the recorded corrosion rates are similar.
引用
收藏
页数:20
相关论文
共 50 条
  • [41] On-site transient analysis for the corrosion assessment of reinforced concrete
    Christodoulou, C.
    Goodier, C. I.
    Austin, S. A.
    Webb, J.
    Glass, G.
    CORROSION SCIENCE, 2012, 62 : 176 - 183
  • [42] Role of sensors in corrosion monitoring and durability assessment in concrete structures: the state of the art
    Ha, TH
    Muralidharan, S
    Bae, JH
    Ha, YC
    Lee, HG
    Park, KW
    Kim, DK
    SENSORS AND MATERIALS, 2004, 16 (03) : 133 - 158
  • [43] Corrosion of reinforced steel bars embedded in concrete:: A study of electrochemical and surface analysis
    Bartolo-Pérez, P
    Peña, JL
    Salas, FH
    Wheat, HG
    Hernández-Duque, G
    CORROSION REVIEWS, 2000, 18 (2-3) : 255 - 266
  • [44] Corrosion assessment using ground penetrating radar in reinforced concrete structures: Influential factors and analysis methods
    Faris, Nour
    Zayed, Tarek
    Abdelkader, Eslam Mohammed
    Fares, Ali
    AUTOMATION IN CONSTRUCTION, 2023, 156
  • [45] Corrosion assessment of reinforced concrete structures in corrosive environments in Chinese chemical industry
    Da, H
    Gowers, KR
    Wang, DW
    Li, DW
    Zhao, Z
    Millard, SG
    BRITISH CORROSION JOURNAL, 2001, 36 (01): : 70 - 74
  • [46] Using of Impact-echo Methods to Assessment of Reinforced Concrete Structures Corrosion
    Samarkova, Kristyna
    Chobola, Zdenek
    Stefkova, Daniela
    ADVANCED RESEARCH IN MATERIAL SCIENCE AND MECHANICAL ENGINEERING, PTS 1 AND 2, 2014, 446-447 : 1400 - 1404
  • [47] DAMAGE ANALYSIS AND CRACKING MODEL OF REINFORCED CONCRETE STRUCTURES WITH REBAR CORROSION
    Yu, Jiang
    Zhao, Yuxi
    Jin, Weiliang
    ADVANCES IN CONCRETE STRUCTURAL DURABILITY: PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON DURABILITY OF CONCRETE STRUCTURES ICDCS2010, 2010, : 415 - 424
  • [48] Damage analysis and cracking model of reinforced concrete structures with rebar corrosion
    Zhao, Yuxi
    Yu, Jiang
    Jin, Weiliang
    CORROSION SCIENCE, 2011, 53 (10) : 3388 - 3397
  • [49] Seismic fragility analysis of reinforced concrete structures considering reinforcement corrosion
    Dai K.
    Yu X.
    Li Y.
    Lü D.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2022, 43 (08): : 20 - 31
  • [50] Conservation of historical reinforced concrete structures damaged by carbonation induced corrosion by means of electrochemical realkalisation
    Bertolini, Luca
    Carsana, Maddalena
    Redaelli, Elena
    JOURNAL OF CULTURAL HERITAGE, 2008, 9 (04) : 376 - 385