Corrosion Assessment in Reinforced Concrete Structures by Means of Embedded Sensors and Multivariate Analysis-Part 2: Implementation

被引:0
|
作者
Lliso-Ferrando, Josep Ramon [1 ,2 ]
Martinez-Ibernon, Ana [1 ,2 ]
Ramon-Zamora, Jose Enrique [3 ]
Gandia-Romero, Jose Manuel [1 ,2 ]
机构
[1] Univ Politecn Valencia, Res Inst Mol Recognit & Technol Dev IDM, Camino Vera S-N, Valencia 46022, Spain
[2] Univ Politecn Valencia, Sch Architecture, Dept Architectural Construct, Camino Vera S-N, Valencia 46022, Spain
[3] CSIC, Inst Ciencias Construcc Eduardo Torroja, C Serrano Galvache 4, Madrid 28002, Spain
来源
APPLIED SCIENCES-BASEL | 2024年 / 14卷 / 19期
关键词
reinforced concrete structures; corrosion; structural health monitoring; structural management; sensors; remote sensing; corrosion monitoring; multivariate analysis; SERVICE LIFE PREDICTION; STEEL; INFRASTRUCTURE; QUESTIONS; CURRENTS;
D O I
10.3390/app14199002
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The economic cost of repairing corrosion-affected reinforced concrete structures (RCSs) means that reliable and accurate assessment and early detection methods must be sought after. Conventional techniques, such as visual inspections, or measuring either cover layer resistivity or the corrosion potential, are methods that require accessibility and involve personnel having to travel to take in situ measurements. Monitoring by embedded sensors is a much more efficient approach that allows early detection by remote sensing. This work presents the implementation of a new measurement protocol regarding the existing monitoring system called INESSCOM (Integrated Sensor Network for Smart Corrosion Monitoring). Along with the corrosion intensity measurement in embedded sensors, it also proposes monitoring the double layer capacity of the sensors' responses. It aims to determine, along with the rebars' corrosion rate, the triggering agent of the corrosion process. This study was carried out using three reinforced concrete scaled columns that were exposed to different environments. The results demonstrate with this new protocol that the remote INESSCOM monitoring system can establish the corrosion rate and identify the precursor agent of corrosion (carbonation or chlorides), even when the recorded corrosion rates are similar.
引用
收藏
页数:20
相关论文
共 50 条
  • [31] Detection of Multiple Corrosion Thresholds in Reinforced Concrete Structures using Passive Sensors
    Abu-Yosef, Ali E.
    Pasupathy, Praveenkumar
    Wood, Sharon L.
    Neikirk, Dean P.
    NONDESTRUCTIVE CHARACTERIZATION FOR COMPOSITE MATERIALS, AEROSPACE ENGINEERING, CIVIL INFRASTRUCTURE, AND HOMELAND SECURITY 2012, 2012, 8347
  • [32] Evaluation of Reinforced Concrete Structures by Means of a Novel Electrochemical Noise Corrosion Sensor
    Nieves-Mendoza, D.
    Almeraya-Calderon, F.
    Uruchurtu-Chavarin, J.
    Martinez-Villafane, A.
    Chacon-Nava, J.
    Baltazar-Zamora, M.
    Gaona-Tiburcio, C.
    Menchaca, J. Laria
    CORROSION, 2008, 64 (12) : 920 - 928
  • [33] Debond detection using embedded piezoelectric elements for reinforced concrete structures - Part II: Analysis and algorithm
    Wu, F
    Chang, FK
    STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2006, 5 (01): : 17 - 28
  • [34] Assessment of corrosion attack morphology on reinforced concrete structures exposed to chlorides
    Yilmaz, Deniz
    Rossi, Emanuele
    Angst, Ueli
    STRUCTURAL CONCRETE, 2024,
  • [35] Impact-Echo Methods to Assessment Corrosion of Reinforced Concrete Structures
    Samarkova, Kristyna
    Chobola, Zdenek
    Stefkova, Daniela
    Kusak, Ivo
    ADVANCED DEVELOPMENT IN INDUSTRY AND APPLIED MECHANICS, 2014, 627 : 268 - 271
  • [36] Embedded Distributed Optical Fiber Sensors in Reinforced Concrete Structures-A Case Study
    Barrias, Antonio
    Casas, Joan R.
    Villalba, Sergi
    SENSORS, 2018, 18 (04)
  • [37] Structural health monitoring of reinforced concrete beams by means of embedded fiber Bragg grating sensors
    Montanini, R.
    De Domenico, F.
    Freni, F.
    Maugeri, N.
    Recupero, A.
    22ND INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, PTS 1-3, 2012, 8421
  • [38] Reinforced concrete structures, Part 2 - Failure investigation of cooling tower reinforced concrete structures, results and discussion
    Mahgoub, Ahmed
    Corrosion Management, 2021, 2021-February : 16 - 20
  • [39] The corrosion protection of embedded steel reinforcement in reinforced concrete structures using galvanic anodes
    Baenziger, Heinz
    Vogelsang, Joerg
    Schulze, Georg
    CONCRETE REPAIR, REHABILITATION AND RETROFITTING II, 2009, : 305 - 306
  • [40] Development of corrosion sensors for monitoring steel-corroding agents in reinforced concrete structures
    Lee, HS
    Shin, SW
    Ahn, JM
    Kim, YC
    Kho, YT
    MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2003, 54 (04): : 229 - 234