Corrosion Assessment in Reinforced Concrete Structures by Means of Embedded Sensors and Multivariate Analysis-Part 2: Implementation

被引:0
|
作者
Lliso-Ferrando, Josep Ramon [1 ,2 ]
Martinez-Ibernon, Ana [1 ,2 ]
Ramon-Zamora, Jose Enrique [3 ]
Gandia-Romero, Jose Manuel [1 ,2 ]
机构
[1] Univ Politecn Valencia, Res Inst Mol Recognit & Technol Dev IDM, Camino Vera S-N, Valencia 46022, Spain
[2] Univ Politecn Valencia, Sch Architecture, Dept Architectural Construct, Camino Vera S-N, Valencia 46022, Spain
[3] CSIC, Inst Ciencias Construcc Eduardo Torroja, C Serrano Galvache 4, Madrid 28002, Spain
来源
APPLIED SCIENCES-BASEL | 2024年 / 14卷 / 19期
关键词
reinforced concrete structures; corrosion; structural health monitoring; structural management; sensors; remote sensing; corrosion monitoring; multivariate analysis; SERVICE LIFE PREDICTION; STEEL; INFRASTRUCTURE; QUESTIONS; CURRENTS;
D O I
10.3390/app14199002
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The economic cost of repairing corrosion-affected reinforced concrete structures (RCSs) means that reliable and accurate assessment and early detection methods must be sought after. Conventional techniques, such as visual inspections, or measuring either cover layer resistivity or the corrosion potential, are methods that require accessibility and involve personnel having to travel to take in situ measurements. Monitoring by embedded sensors is a much more efficient approach that allows early detection by remote sensing. This work presents the implementation of a new measurement protocol regarding the existing monitoring system called INESSCOM (Integrated Sensor Network for Smart Corrosion Monitoring). Along with the corrosion intensity measurement in embedded sensors, it also proposes monitoring the double layer capacity of the sensors' responses. It aims to determine, along with the rebars' corrosion rate, the triggering agent of the corrosion process. This study was carried out using three reinforced concrete scaled columns that were exposed to different environments. The results demonstrate with this new protocol that the remote INESSCOM monitoring system can establish the corrosion rate and identify the precursor agent of corrosion (carbonation or chlorides), even when the recorded corrosion rates are similar.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Corrosion Assessment in Reinforced Concrete Structures by Means of Embedded Sensors and Multivariate Analysis-Part 1: Laboratory Validation
    Ramon-Zamora, Jose Enrique
    Lliso-Ferrando, Josep Ramon
    Martinez-Ibernon, Ana
    Gandia-Romero, Jose Manuel
    SENSORS, 2023, 23 (21)
  • [2] Embedded Sensors for Corrosion Monitoring of Existing Reinforced Concrete Structures
    Pereira, E. V.
    Figueira, R. B.
    Salta, M. M.
    Fonseca, I. T. E.
    ADVANCED MATERIALS FORUM IV, 2008, 587-588 : 677 - +
  • [3] Reinforcement corrosion assessment capability of surface bonded and embedded piezo sensors for reinforced concrete structures
    Talakokula, Visalakshi
    Bhalla, Suresh
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2015, 26 (17) : 2304 - 2313
  • [4] Reinforced concrete structures, Part 1 - Corrosion assessment methodologies and techniques
    Mahgoub, Ahmed
    Corrosion Management, 2020, 2020-December : 24 - 28
  • [5] Power Transmission for Sensors Embedded in Reinforced Concrete Structures
    Jiang, Shan
    Georgakopoulos, Stavros V.
    Jonah, Olutola
    2012 IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM (APSURSI), 2012,
  • [6] Corrosion inhibitors in reinforced concrete structures Part 2 - Repair system
    Bolzoni, F.
    Goidanich, S.
    Lazzari, L.
    Ormellese, M.
    CORROSION ENGINEERING SCIENCE AND TECHNOLOGY, 2006, 41 (03) : 212 - 220
  • [7] The Performance Analysis of Distributed Brillouin Corrosion Sensors for Steel Reinforced Concrete Structures
    Wei, Heming
    Zhao, Xuefeng
    Kong, Xianglong
    Zhang, Pinglei
    Cui, Yanjun
    Sun, Changsen
    SENSORS, 2014, 14 (01) : 431 - 442
  • [8] Examples of reinforcement corrosion monitoring by embedded sensors in concrete structures
    Martinez, I.
    Andrade, C.
    CEMENT & CONCRETE COMPOSITES, 2009, 31 (08): : 545 - 554
  • [9] Embedded long-period fiber grating sensors for monitoring the steel corrosion in reinforced concrete structures
    Wang, Yan
    Liang, Da-Kai
    Li, Dan
    Hu, Xing-Liu
    Fang, Ting
    Guangdianzi Jiguang/Journal of Optoelectronics Laser, 2012, 23 (08): : 1539 - 1544
  • [10] Wireless threshold sensors for detecting corrosion in reinforced concrete structures
    Dickerson, Nathan P.
    Andringa, Matthew M.
    Puryear, John M.
    Wood, Sharon L.
    Neikirk, Dean P.
    SMART STRUCTURES AND MATERIALS 2006: SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL , AND AEROSPACE SYSTEMS, PTS 1 AND 2, 2006, 6174