Formation analysis of cooling load from envelopes under air-conditioning intermittent operation

被引:0
|
作者
Guan, Yifan [1 ]
Hu, Chenxi [1 ]
Meng, Xi [1 ]
机构
[1] Qingdao Univ Technol, iSMART, Qingdao 266033, Peoples R China
关键词
The cooling load; Building envelope; Air-conditioning intermittent operation; THERMAL PERFORMANCE; OPTIMIZATION; STRATEGY; SYSTEM;
D O I
10.1016/j.solener.2025.113428
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Air-conditioning intermittent operation is commonly employed in office buildings due to occupancy regulations. However, existing research on intermittent operation has mainly focused on individual walls or rooms, with limited investigation into cooling load formation from a whole-building perspective, which is crucial for enhancing energy efficiency in both interior and exterior envelopes. Therefore, this study constructed three representative office buildings and conducted numerical simulation to analyze the formation of cooling load within these buildings. The results demonstrated that optimizing the envelope while considering air-conditioning intermittent operation could significantly reduce the cooling load of the building, including the cooling load of the exterior wall, interior wall and floor slab by 25.57 %, 17.92 %-30.81 % and 58.85 %, respectively. The cooling load of the three office buildings studied can be reduced by 31.98 %-35.11 %, with interior walls and floor slabs contributing up to 82.28 %-89.53 %. This study provides valuable insights into future building design and energy-efficient retrofitting of existing buildings and identifies substantial energy-saving potential.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] THE CHOICE OF AIR-CONDITIONING COOLING/HEATING SOURCES
    Guo, Yonghui
    Tan, Yingying
    Zhang, Guoqiang
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 1874 - 1882
  • [32] Cooling Load and Exergy Destruction Analysis in Air Conditioning Operation Room with Ambient Temperature Variation
    Yohana, Eflita
    Romadhon, Revki
    Luhung, Binawan
    Fernando, Irwan
    Utomo, M. S. K. Tony Suryo
    3RD INTERNATIONAL CONFERENCE ON ENERGY, ENVIRONMENTAL AND INFORMATION SYSTEM (ICENIS 2018), 2018, 73
  • [33] Predictive model of cooling load for ice storage air-conditioning system by using GBDT
    Zhang, Wanhu
    Yu, Junqi
    Zhao, Anjun
    Zhou, Xinwei
    ENERGY REPORTS, 2021, 7 : 1588 - 1597
  • [34] Impact of energy-conservation measures on cooling load and air-conditioning plant capacity
    Maheshwari, GP
    Al-Murad, R
    APPLIED ENERGY, 2001, 69 (01) : 59 - 67
  • [35] Development of a cooling load prediction model for air-conditioning system control of office buildings
    Fan, Chengliang
    Liao, Yundan
    Ding, Yunfei
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2019, 14 (01) : 70 - 75
  • [36] Energy consumption analysis of the combined evaporative cooling and cooling ceiling air-conditioning system
    Huang, Xiang
    Li, Yinming
    Wu, Junmei
    PROCEEDINGS OF THE 3RD ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING VOLS I AND II, 2006, : 201 - +
  • [37] A numerical analysis for the cooling module related to automobile air-conditioning system
    Kim, Hak Jun
    Kim, Charn-Jung
    APPLIED THERMAL ENGINEERING, 2008, 28 (14-15) : 1896 - 1905
  • [38] Cost Effectiveness Analysis for an Air-Conditioning System with Water Spray Cooling
    Han, Kai
    ASHRAE TRANSACTIONS 2020, VOL 126, 2020, 126 : 284 - 291
  • [39] Performance analysis on system-level integration and operation of daytime radiative cooling technology for air-conditioning in buildings
    Zhou, Kai
    Miljkovic, Nenad
    Cai, Lili
    ENERGY AND BUILDINGS, 2021, 235
  • [40] Power Retailer Air-Conditioning Load Aggregation Operation Control Method and Demand Response
    Kong, Xiangyu
    Sun, Bowei
    Zhang, Jian
    Li, Shupeng
    Yang, Qun
    IEEE ACCESS, 2020, 8 : 112041 - 112056