Formation analysis of cooling load from envelopes under air-conditioning intermittent operation

被引:0
|
作者
Guan, Yifan [1 ]
Hu, Chenxi [1 ]
Meng, Xi [1 ]
机构
[1] Qingdao Univ Technol, iSMART, Qingdao 266033, Peoples R China
关键词
The cooling load; Building envelope; Air-conditioning intermittent operation; THERMAL PERFORMANCE; OPTIMIZATION; STRATEGY; SYSTEM;
D O I
10.1016/j.solener.2025.113428
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Air-conditioning intermittent operation is commonly employed in office buildings due to occupancy regulations. However, existing research on intermittent operation has mainly focused on individual walls or rooms, with limited investigation into cooling load formation from a whole-building perspective, which is crucial for enhancing energy efficiency in both interior and exterior envelopes. Therefore, this study constructed three representative office buildings and conducted numerical simulation to analyze the formation of cooling load within these buildings. The results demonstrated that optimizing the envelope while considering air-conditioning intermittent operation could significantly reduce the cooling load of the building, including the cooling load of the exterior wall, interior wall and floor slab by 25.57 %, 17.92 %-30.81 % and 58.85 %, respectively. The cooling load of the three office buildings studied can be reduced by 31.98 %-35.11 %, with interior walls and floor slabs contributing up to 82.28 %-89.53 %. This study provides valuable insights into future building design and energy-efficient retrofitting of existing buildings and identifies substantial energy-saving potential.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] AIR-CONDITIONING WITH AMMONIA FOR DISTRICT COOLING
    TOTH, SJ
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1994, 36 (07): : 28 - &
  • [22] COOLING AND AIR-CONDITIONING ON INTERCLIMA 77
    GROOS, J
    KALTE UND KLIMATECHNIK, 1977, 30 (08): : 298 - &
  • [23] Effect of inner decoration coating on inner surface temperatures and heat flows under air-conditioning intermittent operation
    Meng, Xi
    Du, Junfei
    Gao, Yanna
    Yu, Hanting
    CASE STUDIES IN THERMAL ENGINEERING, 2019, 14
  • [24] Effect of the insulation materials filling on the thermal performance of sintered hollow bricks under the air-conditioning intermittent operation
    Hou, Chaoping
    Meng, Xi
    Gao, Yanna
    Mao, Wei
    Long, Enshen
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2018, 8 : 217 - 225
  • [25] AN ARMA TYPE WEATHER MODEL FOR AIR-CONDITIONING, HEATING AND COOLING LOAD CALCULATION
    YOSHIDA, H
    TERAI, T
    ENERGY AND BUILDINGS, 1991, 16 (1-2) : 625 - 634
  • [26] Removing of moisture load in cooling ceiling air-conditioning system by rotary dehumidifier
    Ding, Yun-Fei
    Ding, Jing
    Wang, Zhuo-Yue
    Yang, Xiao-Xi
    Huanan Ligong Daxue Xuebao/Journal of South China University of Technology (Natural Science), 2004, 32 (03): : 10 - 14
  • [27] Simulation and analysis of combined evaporative cooling and cooling ceiling air-conditioning system
    Huang, Xiang
    Li, Yinming
    Wu, Junmei
    Huagong Xuebao/Journal of Chemical Industry and Engineering (China), 2006, 57 (SUPPL.): : 205 - 208
  • [28] Predicting the Air-conditioning Load under Drought Conditions Based on ELM
    Wang, Zhaokun
    Zhang, Xiaoyang
    Lai, Mingyong
    Liu, Baoping
    ADVANCED MATERIALS AND COMPUTER SCIENCE, PTS 1-3, 2011, 474-476 : 1326 - +
  • [29] Effect of the thermal insulation layer location on wall dynamic thermal response rate under the air-conditioning intermittent operation
    Zhang, Lili
    Luo, Tao
    Meng, Xi
    Wang, Yating
    Hou, Chaoping
    Long, Enshen
    CASE STUDIES IN THERMAL ENGINEERING, 2017, 10 : 79 - 85
  • [30] Bioaerosol deposition on an air-conditioning cooling coil
    Wu, Yan
    Chen, Ailu
    Luhung, Irvan
    Gall, Elliott T.
    Cao, Qingliang
    Chang, Victor Wei-Chung
    Nazaroff, William W.
    ATMOSPHERIC ENVIRONMENT, 2016, 144 : 257 - 265