Factors influencing the results of air samplers in closed, air-conditioned patient rooms—a numerical study

被引:0
|
作者
Christian Ernst [1 ]
Martin Heinrich [1 ]
Rüdiger Schwarze [1 ]
机构
[1] TU Bergakademie Freiberg,Institute for Mechanics and Fluid Dynamics
关键词
Aerosol distribution; Air sampling; SARS-CoV-2; CFD; ILES; Patient room; Droplet evaporation;
D O I
10.1007/s11356-025-36036-9
中图分类号
学科分类号
摘要
Several air sampling studies have been conducted to assess the risk of airborne transmission since the outbreak of SARS-CoV-2 in late 2019. However, differences in sampler positioning and positive collection results in more distant locations suggest an interaction between the sampler and the indoor air flow, altering the aerosol distribution. This study aims to investigate this influence by studying multiple collector positions, patient exhalation modes, and two ventilation setups in a 3D simulation model using implicit large-eddy simulations along with evaporative Lagrangian particles. The results of this study show a higher total aerosol particle amount in the patient room with the deployment of a sampling device, possibly increasing infection risk for medical personal during and shortly after a sampling procedure. Furthermore, the variation of the collector position reveals an impact on the sampling yield, thus rendering even more distant positions viable and potentially beneficial in terms of maintaining sampler performance and increasing patient comfort. Moreover, the influence of ventilation was investigated suggesting the deactivation to increase aerosol concentration during sampling campaigns for efficient sampling. Additionally, results indicate an impact on room flow by air samplers and subsequent sampling yield, potentially necessitating reassessments of conclusions drawn from previous sampler studies. Finally, it can be concluded that future air sampling campaigns, which are preliminarily assessed using numerical simulation, could benefit from advantageous positioning to aid sampling success.
引用
收藏
页码:7680 / 7691
页数:11
相关论文
共 50 条
  • [31] WOUND CONTAMINATION IN CONVENTIONALLY AIR-CONDITIONED OPERATING-ROOMS AS COMPARED TO LAMINAR-FLOW-OPERATING-ROOMS
    BOTZENHART, K
    HOPPENKAMPS, G
    ZENTRALBLATT FUR BAKTERIOLOGIE MIKROBIOLOGIE UND HYGIENE SERIE B-UMWELTHYGIENE KRANKENHAUSHYGIENE ARBEITSHYGIENE PRAVENTIVE MEDIZIN, 1978, 167 (1-2): : 29 - 37
  • [32] Numerical simulation research on delaminlation phenomena of ordinary air-conditioned room
    Wang, HQ
    Tang, GF
    Huang, CH
    Kou, GX
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 1817 - 1824
  • [33] Numerical simulation of the aerosol formation and spreading in an air-conditioned train compartment
    Konstantinov, M.
    Schmeling, D.
    Wagner, C.
    JOURNAL OF AEROSOL SCIENCE, 2023, 170
  • [34] Factors influencing microbial colonies in the air of operating rooms
    Ling Fu Shaw
    Ian Horng Chen
    Chii Shya Chen
    Hui Hsin Wu
    Li Shing Lai
    Yin Yin Chen
    Fu Der Wang
    BMC Infectious Diseases, 18
  • [35] Factors influencing microbial colonies in the air of operating rooms
    Shaw, Ling Fu
    Chen, Ian Horng
    Chen, Chii Shya
    Wu, Hui Hsin
    Lai, Li Shing
    Chen, Yin Yin
    Wang, Fu Der
    BMC INFECTIOUS DISEASES, 2018, 18
  • [36] Influence of vertical greenery systems and green roofs on the indoor operative temperature of air-conditioned rooms
    Hao, Xiaoli
    Xing, Qingwei
    Long, Pinhan
    Lin, Yaolin
    Hu, Jinhua
    Tan, Hang
    JOURNAL OF BUILDING ENGINEERING, 2020, 31
  • [37] Feasibility study of an express assessment protocol for the indoor air quality of air-conditioned offices
    Hui, P. S.
    Wong, L. T.
    Mui, K. W.
    INDOOR AND BUILT ENVIRONMENT, 2006, 15 (04) : 373 - 378
  • [38] Numerical simulation of passenger air-conditioned compartment air flow and heat transfer conjugated with car body
    Chen, JP
    Tong, L
    Chen, ZJ
    Que, XC
    CRYOGENICS AND REFRIGERATION - PROCEEDINGS OF ICCR 98, 1998, : 365 - 368
  • [39] NUMERICAL SIMULATION AND EXPERIMENTAL STUDY OF THE TEMPERATURE FIELD AND AIRFLOW INSIDE THE AIR-CONDITIONED PASSENGER COMPARTMENT
    Xiang, Liping
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 1804 - 1811
  • [40] Student learning performance and indoor environmental quality (IEQ) in air-conditioned university teaching rooms
    Lee, M. C.
    Mui, K. W.
    Wong, L. T.
    Chan, W. Y.
    Lee, E. W. M.
    Cheung, C. T.
    BUILDING AND ENVIRONMENT, 2012, 49 : 238 - 244