Factors influencing the results of air samplers in closed, air-conditioned patient rooms—a numerical study

被引:0
|
作者
Christian Ernst [1 ]
Martin Heinrich [1 ]
Rüdiger Schwarze [1 ]
机构
[1] TU Bergakademie Freiberg,Institute for Mechanics and Fluid Dynamics
关键词
Aerosol distribution; Air sampling; SARS-CoV-2; CFD; ILES; Patient room; Droplet evaporation;
D O I
10.1007/s11356-025-36036-9
中图分类号
学科分类号
摘要
Several air sampling studies have been conducted to assess the risk of airborne transmission since the outbreak of SARS-CoV-2 in late 2019. However, differences in sampler positioning and positive collection results in more distant locations suggest an interaction between the sampler and the indoor air flow, altering the aerosol distribution. This study aims to investigate this influence by studying multiple collector positions, patient exhalation modes, and two ventilation setups in a 3D simulation model using implicit large-eddy simulations along with evaporative Lagrangian particles. The results of this study show a higher total aerosol particle amount in the patient room with the deployment of a sampling device, possibly increasing infection risk for medical personal during and shortly after a sampling procedure. Furthermore, the variation of the collector position reveals an impact on the sampling yield, thus rendering even more distant positions viable and potentially beneficial in terms of maintaining sampler performance and increasing patient comfort. Moreover, the influence of ventilation was investigated suggesting the deactivation to increase aerosol concentration during sampling campaigns for efficient sampling. Additionally, results indicate an impact on room flow by air samplers and subsequent sampling yield, potentially necessitating reassessments of conclusions drawn from previous sampler studies. Finally, it can be concluded that future air sampling campaigns, which are preliminarily assessed using numerical simulation, could benefit from advantageous positioning to aid sampling success.
引用
收藏
页码:7680 / 7691
页数:11
相关论文
共 50 条
  • [1] AIR MOVEMENTS IN ILLUMINATED AND AIR-CONDITIONED ROOMS
    SOLLNER, G
    LICHTTECHNIK, 1970, 22 (01): : 17 - &
  • [2] HEAT BALANCE IN AIR-CONDITIONED ROOMS
    HANSEN, E
    MADSEN, TL
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1972, 16 (01) : 27 - &
  • [3] TEMPERATURE DISTRIBUTIONS IN AIR-CONDITIONED ROOMS
    PALLIER, JM
    YEZOU, R
    BRAU, J
    APPLIED ENERGY, 1983, 14 (01) : 49 - 64
  • [4] Wall/roof thermal performance differences between air-conditioned and non air-conditioned rooms
    Barrios, G.
    Huelsz, G.
    Rechtman, R.
    Rojas, J.
    ENERGY AND BUILDINGS, 2011, 43 (01) : 219 - 223
  • [5] MEASUREMENT OF SMALL AIR VELOCITIES IN AIR-CONDITIONED ROOMS.
    Gasser, R.
    Sulzer Technical Review, 1974, 56 (02): : 105 - 114
  • [6] LEGIONELLOSIS IN A CLOSED AIR-CONDITIONED WORK PLACE
    HERENDI, A
    ZADOR, A
    KEKESI, Z
    TABAK, P
    ACTA MICROBIOLOGICA HUNGARICA, 1988, 35 (02): : 186 - 186
  • [7] Application of Numerical Simulation Technology In the large Space Air-conditioned Buildings Air-conditioned Buildings
    Li Jianwei
    Feng Zengxi
    ADVANCED DEVELOPMENT IN AUTOMATION, MATERIALS AND MANUFACTURING, 2014, 624 : 657 - 660
  • [8] Experimental and Numerical Model Investigations of Oxygen-Enriched Characteristics in Air-Conditioned Rooms
    Zhang, Chuanzhao
    Yang, Xiong
    Li, Ziyi
    Liu, Yingshu
    Zhao, Yu
    Wang, Haoyu
    Ma, Xiaojun
    Li, Chunwang
    Zhang, Yuanhui
    APPLIED SCIENCES-BASEL, 2021, 11 (11):
  • [9] Air quality appraisal in air-conditioned spaces: Numerical analysis
    Kameel, R
    Khalil, EE
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 287 - 294
  • [10] FIELD STUDY OF AIR QUALITY IN AIR-CONDITIONED SPACES
    SWANTON, JR
    ASHRAE JOURNAL, 1971, 13 (01): : 55 - &