摘要
BackgroundPhoton counting computed tomography (PCCT) employs direct and spectrally resolved counting of individual x-ray quanta, enhancing image quality compared to the standard energy-integrating CT (EICT).PurposeTo evaluate the quantitative improvements in CT image quality metrics by comparing the first medical PCCT with a state-of-the-art EICT.MethodsThe PCCT versus EICT noise improvement ratio R was derived from the quantum statistics of the measurement process and measured across the clinical x-ray flux range for both systems. Detector and system modulation transfer functions (MTFs) were obtained using tilted-slit and wire phantom measurements. Image root mean square (RMS) noise, noise power spectrum (NPS), and x-ray patient dose were compared using a CatPhan phantom at two identical clinical target resolutions.ResultsThe measurement of the PCCT noise improvement ratio R showed an elimination of electronic noise and a 10% noise transfer advantage. The PCCT detector MTF exhibited 3x higher angular resolution limits in comparison to EICT and close to ideal sinc behavior due to the electromagnetic formation of pixels in the PCCT semiconductor detector. This translated to 3.5x enhancements in CT system MTF ratios at 10 LP/cm, reflecting a significant improvement in millimeter range CT imaging. Both the improved quantum detection and the system MTF ratio improvement contribute to the measured 3x enhancements in image NPS at 10 LP/cm for identical image target resolution. An improvement of up to 1.7x in RMS image noise was observed accordingly. For low and ultra-low dose imaging with image filtering, dose efficiency increased between 2x and 10x, demonstrating the PCCT's capability to advance CT ultra-low dose imaging.ConclusionThe direct counting detection in PCCT has been shown to significantly improve sinogram noise and detector MTF ratios compared to energy integrating EICT. The observed translations into CT system MTF, image NPS, image noise, and dose ratios reflect a paradigm shift for CT image quality and dose efficiency.
引用
收藏
页码:1526 / 1535
页数:10
相关论文
共 50 条
  • [21] Image quality of photon-counting detector CT for visualization of maxillofacial anatomy in comparison with energy-integrating detector CT and intraoperative C-arm CBCT
    Klintstrom, Eva
    Ly, Adam
    Sandborg, Michael
    Woisetschlager, Mischa
    Tesselaar, Erik
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 181
  • [22] Comparison of Low Dose Performance of Photon-Counting and Energy Integrating CT
    Rajagopal, Jayasai R.
    Farhadi, Faraz
    Solomon, Justin
    Sahbaee, Pooyan
    Saboury, Babak
    Pritchard, William F.
    Jones, Elizabeth C.
    Samei, Ehsan
    ACADEMIC RADIOLOGY, 2021, 28 (12) : 1754 - 1760
  • [23] Comparison of low-energy virtual monoenergetic images between photon-counting CT and energy-integrating detectors CT: A phantom study
    Greffier, Joel
    Faby, Sebastian
    Pastor, Maxime
    Frandon, Julien
    Erath, Julien
    Beregi, Jean Paul
    Dabli, Djamel
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2024, 105 (09) : 311 - 318
  • [24] Infrapopliteal Segments on Lower Extremity CTA: Prospective Intraindividual Comparison of Energy-Integrating Detector CT and Photon-Counting Detector CT
    Yalon, Mariana
    Inoue, Akitoshi
    Thorne, Jamison E.
    Lee, Yong S.
    Johnson, Matthew P.
    Esquivel, Andrea
    Leng, Shuai
    McCollough, Cynthia H.
    Fletcher, Joel G.
    Rajiah, Prabhakar Shantha
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2024, 222 (03)
  • [25] Photon-Counting Versus Energy-Integrating Detector CT Angiography of the Lower Extremity in a Human Cadaveric Model With Continuous Extracorporeal Perfusion
    Gruschwitz, Philipp
    Hartung, Viktor
    Kleefeldt, Florian
    Ergun, Suleyman
    Huflage, Henner
    Peter, Dominik
    Hendel, Robin
    Patzer, Theresa Sophie
    Pannenbecker, Pauline
    Kuhl, Philipp Josef
    Bley, Thorsten Alexander
    Petritsch, Bernhard
    Grunz, Jan-Peter
    INVESTIGATIVE RADIOLOGY, 2023, 58 (10) : 740 - 745
  • [26] Photon-counting versus energy-integrating CT of abdomen-pelvis: a phantom study on the potential for reducing iodine contrast media
    Djamel Dabli
    Maxime Pastor
    Sebastian Faby
    Julien Erath
    Cédric Croisille
    Fabricio Pereira
    Jean-Paul Beregi
    Joël Greffier
    European Radiology Experimental, 9 (1)
  • [27] Visualization of bone details in a novel photon-counting dual-source CT scanner-comparison with energy-integrating CT
    Bette, Stefanie J.
    Braun, Franziska M.
    Haerting, Mark
    Decker, Josua A.
    Luitjens, Jan H.
    Scheurig-Muenkler, Christian
    Kroencke, Thomas J.
    Schwarz, Florian
    EUROPEAN RADIOLOGY, 2022, 32 (05) : 2930 - 2936
  • [28] A New Iterative Metal Artifact Reduction Algorithm for Both Energy-Integrating and Photon-Counting CT Systems
    Anhaus, Julian A.
    Heider, Maximilian
    Killermann, Philipp
    Hofmann, Christian
    Mahnken, Andreas H.
    INVESTIGATIVE RADIOLOGY, 2024, 59 (07) : 526 - 537
  • [29] Dual source hybrid spectral micro-CT using an energy-integrating and a photon-counting detector
    Holbrook, M. D.
    Clark, D. P.
    Badea, C. T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (20):
  • [30] Detection of myeloma-associated osteolytic bone lesions with energy-integrating and photon-counting detector CT
    Groezinger, Martin
    Wennmann, Markus
    Sawall, Stefan
    Wehrse, Eckhard
    Sedaghat, Sam
    Neelsen, Christian
    Bauer, Fabian
    Goldschmidt, Hartmut
    Weru, Vivienn
    Ziener, Christian H.
    Kopp-Schneider, Annette
    Schlemmer, Heinz-Peter
    Rotkopf, Lukas T.
    RADIOLOGIE, 2024, 64 (SUPPL 1): : 24 - 31