Photon counting CT versus energy-integrating CT: A comparative evaluation of advances in image resolution, noise, and dose efficiency

被引:0
|
作者
Heismann, Bjoern [1 ,2 ]
Kreisler, Bjoern [2 ]
Fasbender, Robert [2 ]
机构
[1] Friedrich Alexander Univ Erlangen Nuremberg, Siemens Healthineers AG, Forchheim, Germany
[2] Siemens Healthineers AG, Siemensstr 3, D-91301 Forchheim, Germany
关键词
computed tomography; CT Image quality; dose efficiency; photon counting; DETECTOR;
D O I
10.1002/mp.17591
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundPhoton counting computed tomography (PCCT) employs direct and spectrally resolved counting of individual x-ray quanta, enhancing image quality compared to the standard energy-integrating CT (EICT).PurposeTo evaluate the quantitative improvements in CT image quality metrics by comparing the first medical PCCT with a state-of-the-art EICT.MethodsThe PCCT versus EICT noise improvement ratio R was derived from the quantum statistics of the measurement process and measured across the clinical x-ray flux range for both systems. Detector and system modulation transfer functions (MTFs) were obtained using tilted-slit and wire phantom measurements. Image root mean square (RMS) noise, noise power spectrum (NPS), and x-ray patient dose were compared using a CatPhan phantom at two identical clinical target resolutions.ResultsThe measurement of the PCCT noise improvement ratio R showed an elimination of electronic noise and a 10% noise transfer advantage. The PCCT detector MTF exhibited 3x higher angular resolution limits in comparison to EICT and close to ideal sinc behavior due to the electromagnetic formation of pixels in the PCCT semiconductor detector. This translated to 3.5x enhancements in CT system MTF ratios at 10 LP/cm, reflecting a significant improvement in millimeter range CT imaging. Both the improved quantum detection and the system MTF ratio improvement contribute to the measured 3x enhancements in image NPS at 10 LP/cm for identical image target resolution. An improvement of up to 1.7x in RMS image noise was observed accordingly. For low and ultra-low dose imaging with image filtering, dose efficiency increased between 2x and 10x, demonstrating the PCCT's capability to advance CT ultra-low dose imaging.ConclusionThe direct counting detection in PCCT has been shown to significantly improve sinogram noise and detector MTF ratios compared to energy integrating EICT. The observed translations into CT system MTF, image NPS, image noise, and dose ratios reflect a paradigm shift for CT image quality and dose efficiency.
引用
收藏
页码:1526 / 1535
页数:10
相关论文
共 50 条
  • [11] Coronary Plaque Quantification with Ultrahigh-Spatial-Resolution Photon-counting Detector CT: Intraindividual Comparison with Energy-integrating Detector CT
    Vecsey-Nagy, Milan
    Tremamunno, Giuseppe
    Schoepf, U. Joseph
    Gnasso, Chiara
    Zsarnoczay, Emese
    Fink, Nicola
    Kravchenko, Dmitrij
    Halfmann, Moritz C.
    O'Doherty, Jim
    Szilveszter, Balint
    Maurovich-Horvat, Pal
    Kabakus, Ismail Mikdat
    Suranyi, Pal Spruill
    Emrich, Tilman
    Varga-Szemes, Akos
    RADIOLOGY, 2025, 314 (03)
  • [12] Photon- Counting Detector CT Versus Energy- Integrating Detector CT of the Lumbar Spine: Comparison of Radiation Dose and Image Quality
    Marth, Adrian A.
    Marcus, Roy P.
    Feuerriegel, Georg C.
    Nanz, Daniel
    Sutter, Reto
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2024, 222 (01)
  • [13] Optimizing Chest CT With Photon-counting Detector Technology: Comparison to Established Energy-integrating Detector CT Protocols
    Alarab, N.
    Guo, J.
    Atha, J.
    Sieren, J. C.
    Puliyakote, A. S. Kizhakke
    Hoffman, E. A.
    Abadi, E.
    Fain, S. B.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2024, 209
  • [14] A comparative study of image quality and diagnostic confidence in diagnosis and follow-up of scaphoid fractures using photon-counting detector CT and energy-integrating detector CT
    Kammerling, Nina
    Tesselaar, Erik
    Booij, Ronald
    Fornander, Lotta
    Persson, Anders
    Farnebo, Simon
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 173
  • [15] Detection of Post-COVID-19 Lung Abnormalities: Photon-counting CT versus Same-Day Energy-integrating Detector CT
    Prayer, Florian
    Kienast, Patric
    Strassl, Andreas
    Moser, Philipp T.
    Bernitzky, Dominik
    Milacek, Christopher
    Gyoengyoesi, Mariann
    Kifjak, Daria
    Roehrich, Sebastian
    Beer, Lucian
    Watzenboeck, Martin L.
    Milos, Ruxandra I.
    Wassipaul, Christian
    Gompelmann, Daniela
    Herold, Christian J.
    Prosch, Helmut
    Heidinger, Benedikt H.
    RADIOLOGY, 2023, 307 (01)
  • [16] Visualization of bone details in a novel photon-counting dual-source CT scanner—comparison with energy-integrating CT
    Stefanie J. Bette
    Franziska M. Braun
    Mark Haerting
    Josua A. Decker
    Jan H. Luitjens
    Christian Scheurig-Muenkler
    Thomas J. Kroencke
    Florian Schwarz
    European Radiology, 2022, 32 : 2930 - 2936
  • [17] Giant Thrombus in a Coronary Artery Bypass Graft: Comparison of Photon-counting Detector CT and Energy-integrating Detector CT
    Zhang, Huixin
    Jin, Dongsheng
    RADIOLOGY, 2024, 313 (03)
  • [18] Material decomposition from photon-counting CT using a convolutional neural network and energy-integrating CT training labels
    Nadkarni, Rohan
    Allphin, Alex
    Clark, Darin P.
    Badea, Cristian T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (15):
  • [19] Coronary CT angiography-based FFR with ultrahigh-resolution photon-counting detector CT: Intra-individual comparison to energy-integrating detector CT
    Vecsey-Nagy, Milan
    Tremamunno, Giuseppe
    Schoepf, U. Joseph
    Gnasso, Chiara
    Zsarnoczay, Emese
    Fink, Nicola
    Kravchenko, Dmitrij
    Hagar, Muhammad Taha
    Halfmann, Moritz C.
    Jokkel, Zsofia
    O'Doherty, Jim
    Szilveszter, Balint
    Maurovich-Horvat, Pal
    Suranyi, Pal Spruill
    Varga-Szemes, Akos
    Emrich, Tilman
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 181
  • [20] Comparison Study of Myocardial Radiomics Feature Properties on Energy-Integrating and Photon-Counting Detector CT
    Ayx, Isabelle
    Tharmaseelan, Hishan
    Hertel, Alexander
    Noerenberg, Dominik
    Overhoff, Daniel
    Rotkopf, Lukas T.
    Riffel, Philipp
    Schoenberg, Stefan O.
    Froelich, Matthias F.
    DIAGNOSTICS, 2022, 12 (05)