Photon counting CT versus energy-integrating CT: A comparative evaluation of advances in image resolution, noise, and dose efficiency

被引:0
|
作者
Heismann, Bjoern [1 ,2 ]
Kreisler, Bjoern [2 ]
Fasbender, Robert [2 ]
机构
[1] Friedrich Alexander Univ Erlangen Nuremberg, Siemens Healthineers AG, Forchheim, Germany
[2] Siemens Healthineers AG, Siemensstr 3, D-91301 Forchheim, Germany
关键词
computed tomography; CT Image quality; dose efficiency; photon counting; DETECTOR;
D O I
10.1002/mp.17591
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundPhoton counting computed tomography (PCCT) employs direct and spectrally resolved counting of individual x-ray quanta, enhancing image quality compared to the standard energy-integrating CT (EICT).PurposeTo evaluate the quantitative improvements in CT image quality metrics by comparing the first medical PCCT with a state-of-the-art EICT.MethodsThe PCCT versus EICT noise improvement ratio R was derived from the quantum statistics of the measurement process and measured across the clinical x-ray flux range for both systems. Detector and system modulation transfer functions (MTFs) were obtained using tilted-slit and wire phantom measurements. Image root mean square (RMS) noise, noise power spectrum (NPS), and x-ray patient dose were compared using a CatPhan phantom at two identical clinical target resolutions.ResultsThe measurement of the PCCT noise improvement ratio R showed an elimination of electronic noise and a 10% noise transfer advantage. The PCCT detector MTF exhibited 3x higher angular resolution limits in comparison to EICT and close to ideal sinc behavior due to the electromagnetic formation of pixels in the PCCT semiconductor detector. This translated to 3.5x enhancements in CT system MTF ratios at 10 LP/cm, reflecting a significant improvement in millimeter range CT imaging. Both the improved quantum detection and the system MTF ratio improvement contribute to the measured 3x enhancements in image NPS at 10 LP/cm for identical image target resolution. An improvement of up to 1.7x in RMS image noise was observed accordingly. For low and ultra-low dose imaging with image filtering, dose efficiency increased between 2x and 10x, demonstrating the PCCT's capability to advance CT ultra-low dose imaging.ConclusionThe direct counting detection in PCCT has been shown to significantly improve sinogram noise and detector MTF ratios compared to energy integrating EICT. The observed translations into CT system MTF, image NPS, image noise, and dose ratios reflect a paradigm shift for CT image quality and dose efficiency.
引用
收藏
页码:1526 / 1535
页数:10
相关论文
共 50 条
  • [1] Comparison of Image Quality and Radiation Dose in Pediatric Temporal Bone CT Using Photon-Counting Detector CT and Energy-Integrating Detector CT
    Lee, Jeong Sub
    Kim, John
    Bapuraj, Jayapalli R.
    Srinivasan, Ashok
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2024, 45 (09) : 1322 - 1326
  • [2] Low-dose CT of the abdomen: Initial experience on a novel photon-counting detector CT and comparison with energy-integrating detector CT
    Decker, Josua A.
    Bette, Stefanie
    Lubina, Nora
    Rippel, Katharina
    Braun, Franziska
    Risch, Franka
    Wollny, Claudia
    Scheurig-Muenkler, Christian
    Kroencke, Thomas J.
    Schwarz, Florian
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 148
  • [3] High-Resolution Head CTA: A Prospective Patient Study Comparing Image Quality of Photon-Counting Detector CT and Energy-Integrating Detector CT
    Diehn, Felix E.
    Zhou, Zhongxing
    Thorne, Jamison E.
    Campeau, Norbert G.
    Nagelschneider, Alex A.
    Eckel, Laurence J.
    Benson, John C.
    Madhavan, Ajay A.
    Bathla, Girish
    Lehman, Vance T.
    Huber, Nathan R.
    Baffour, Francis
    Fletcher, Joel G.
    McCollough, Cynthia H.
    Yu, Lifeng
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2024, 45 (10) : 1441 - 1449
  • [4] Abdominal image quality and dose reduction with energy-integrating or photon-counting detectors dual-source CT: A phantom study
    Greffiera, Joel
    Dabli, Djamel
    Faby, Sebastian
    Pastor, Maxime
    Croisille, Cedric
    de Oliveira, Fabien
    Erath, Julien
    Beregi, Jean Paul
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2024, 105 (10) : 379 - 385
  • [5] Spectral X-Ray CT Image Reconstruction with a Combination of Energy-Integrating and Photon-Counting Detectors
    Yang, Qingsong
    Cong, Wenxiang
    Xi, Yan
    Wang, Ge
    PLOS ONE, 2016, 11 (05):
  • [6] Contrast-Enhanced Abdominal CT with Clinical Photon-Counting Detector CT: Assessment of Image Quality and Comparison with Energy-Integrating Detector CT
    Higashigaito, Kai
    Euler, Andre
    Eberhard, Matthias
    Flohr, Thomas G.
    Schmidt, Bernhard
    Alkadhi, Hatem
    ACADEMIC RADIOLOGY, 2022, 29 (05) : 689 - 697
  • [7] Low-dose high-resolution chest CT in adults with cystic fibrosis: intraindividual comparison between photon-counting and energy-integrating detector CT
    Frings, Marko
    Welsner, Matthias
    Mousa, Christin
    Zensen, Sebastian
    Salhoefer, Luca
    Meetschen, Mathias
    Beck, Nikolas
    Bos, Denise
    Westhoelter, Dirk
    Wienker, Johannes
    Taube, Christian
    Umutlu, Lale
    Schaarschmidt, Benedikt M.
    Forsting, Michael
    Haubold, Johannes
    Sutharsan, Sivagurunathan
    Opitz, Marcel
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2024, 8 (01)
  • [8] Submillisievert Abdominal Photon-Counting CT versus Energy-integrating Detector CT for Urinary Calculi Detection: Impact on Diagnostic Confidence
    Huflage, Henner
    Kunz, Andreas Steven
    Patzer, Theresa Sophie
    Pichlmeier, Svenja
    Westhofen, Thilo
    Gruschwitz, Philipp
    Heidenreich, Julius Frederik
    Lennartz, Simon
    Bley, Thorsten Alexander
    Grunz, Jan-Peter
    RADIOLOGY, 2024, 312 (01)
  • [9] Image Quality and Radiation Dose of CTPA With Iodine Maps: A Prospective Randomized Study of High-Pitch Mode Photon-Counting Detector CT Versus Energy-Integrating Detector CT
    Pannenbecker, Pauline
    Heidenreich, Julius F.
    Grunz, Jan-Peter
    Huflage, Henner
    Gruschwitz, Philipp
    Patzer, Theresa S.
    Feldle, Philipp
    Bley, Thorsten A.
    Petritsch, Bernhard
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2024, 222 (02)
  • [10] Intraindividual Comparison of Ultrahigh-Spatial-Resolution Photon-Counting Detector CT and Energy-Integrating Detector CT for Coronary Stenosis Measurement
    Vecsey-Nagy, Milan
    Tremamunno, Giuseppe
    Schoepf, U. Joseph
    Gnasso, Chiara
    Zsarnoczay, Emese
    Fink, Nicola
    Kravchenko, Dmitrij
    Halfmann, Moritz C.
    Laux, Gerald S.
    O'Doherty, Jim
    Szilveszter, Balint
    Maurovich-Horvat, Pal
    Kabakus, Ismail Mikdat
    Suranyi, Pal Spruill
    Varga-Szemes, Akos
    Emrich, Tilman
    CIRCULATION-CARDIOVASCULAR IMAGING, 2024, 17 (10)