T2*-weighted imaging for detection of intracranial silicone oil in MRI obtained with motion correction sequences

被引:0
|
作者
Yasuda, Ryuta [1 ,2 ]
Maeda, Masayuki [3 ,4 ]
Takada, Kenichi [3 ]
Inoue, Katsuhiro [4 ]
Sugao, Masataka [5 ]
Suzuki, Hidenori [2 ]
机构
[1] Tohyama Hosp, Dept Neurosurg, 17-22 Minami Shinmachi, Tsu, Mie 5140043, Japan
[2] Mie Univ, Grad Sch Med, Dept Neurosurg, 2-174 Edobashi, Tsu, Mie 5148507, Japan
[3] Tohyama Hosp, Dept Radiol, 17-22 Minami Shinmachi, Tsu, Mie 5140043, Japan
[4] Mie Univ, Grad Sch Med, Dept Neuroradiol, 2-174 Edobashi, Tsu, Mie 5148507, Japan
[5] Tohyama Hosp, Dept Internal Med, 17-22 Minami Shinmachi, Tsu, Mie 5140043, Japan
关键词
Silicone oil; Intracranial migration; T2*-weighted imaging; Motion correction sequence;
D O I
10.1186/s41984-025-00362-4
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BackgroundFor magnetic resonance imaging (MRI) findings of intracranial silicone oil migration, little has been described about images obtained with motion correction sequences such as MultiVane XD (Philips Healthcare) that provides high resolution diagnostic images even with severe patient motion. We report a case with intracranial silicone oil migration in which MRI was obtained with MultiVane XD and T2*-weighted imaging (T2*WI) was found the most useful in detecting intracranial silicone oil.Case presentationA 77-year-old female with a history of eye surgery using silicone oil referred to our hospital due to conscious disturbance. Head computed tomography demonstrated multiple intracranial masses whose signal density was similar to that in the operated eyeball and the tentative diagnosis of intracranial silicone oil migration was made. MRI was performed with MultiVane XD due to the significant patient's restlessness, and among all sequences including T1-weighted imaging (T1WI), T2-weighted imaging (T2WI), fluid-attenuated inversion recovery (FLAIR) and T2*WI, only T2*WI detected intracranial silicone oil. In contrast, another MRI obtained previously with conventional turbo spin-echo detected intracranial silicone oil not only in T2*WI but also in T1WI, T2WI and FLAIR. Phantom experiment revealed that chemical shift artifact played an important role in discriminating silicone oil from artificial cerebrospinal fluid, which attenuated in MultiVane XD. However, T2*WI still showed good discrimination of silicone oil even using MultiVane XD because of susceptibility artifacts.ConclusionT2*WI was the best sequence to detect intracranial silicone oil in MRI obtained with motion correction sequences because of its ability to depict the susceptibility artifacts.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Static and dynamic responses to hyperoxia of normal placenta across gestation with T2*-weighted MRI sequences
    Bartin, R.
    Melbourne, A.
    Bobet, L.
    Gauchard, G.
    Menneglier, A.
    Grevent, D.
    Bussieres, L.
    Siauve, N.
    Salomon, L. J.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2024, 64 (02) : 236 - 244
  • [32] Optimisation of T2*-weighted MRI for the detection of small veins in multiple sclerosis at 3 T and 7 T
    Dixon, Jennifer Elizabeth
    Simpson, Ashley
    Mistry, Niraj
    Evangelou, Nikos
    Morris, Peter Gordon
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (05) : 719 - 727
  • [33] Accuracy of MRI T2*-weighted sequences (GRE-EPI) compared to CTA for detection of anterior circulation large vessel thrombus
    Javier M. Romero
    Afonso C. P. Liberato
    Daniel Montes
    Isabelle Barnaure
    Jing Xu
    Noor Maza
    Ramon G. Gonzalez
    Emergency Radiology, 2020, 27 : 269 - 275
  • [34] Accuracy of MRI T2*-weighted sequences (GRE-EPI) compared to CTA for detection of anterior circulation large vessel thrombus
    Romero, Javier M.
    Liberato, Afonso C. P.
    Montes, Daniel
    Barnaure, Isabelle
    Xu, Jing
    Maza, Noor
    Gonzalez, Ramon G.
    EMERGENCY RADIOLOGY, 2020, 27 (03) : 269 - 275
  • [35] Brain MRI in peripartum seizures: usefulness of combined T2 and diffusion weighted MR imaging
    Shah, AK
    Whitty, JE
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 1999, 166 (02) : 122 - 125
  • [36] Dynamic contrast-enhanced magnetic resonance imaging of the kidney: Comparison of T1-weighted and T2*-weighted sequences
    Tsushima, Y
    Niemi, P
    Komu, M
    Dean, PB
    Haapanen, A
    Kormano, M
    ACADEMIC RADIOLOGY, 1996, 3 : S176 - S178
  • [37] Principles of T2*- Weighted Dynamic Susceptibility Contrast MRI Technique in Brain Tumor Imaging
    Shiroishi, Mark S.
    Castellazzi, Gloria
    Boxerman, Jerrold L.
    D'Amore, Francesco
    Essig, Marco
    Nguyen, Thanh B.
    Provenzale, James M.
    Enterline, David S.
    Anzalone, Nicoletta
    Doerfler, Arnd
    Rovira, Alex
    Wintermark, Max
    Law, Meng
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (02) : 296 - 313
  • [38] Cerebral microbleeds: Accelerated 3D T2*-weighted GRE MR imaging versus conventional 2D T2*-weighted GRE MR imaging for detection
    Vernooij, Meike W.
    Ikram, M. Arfan
    Wielopolski, Piotr A.
    Krestin, Gabriel P.
    Breteler, Monique M. B.
    van der Lugt, Aad
    RADIOLOGY, 2008, 248 (01) : 272 - 277
  • [39] T2*weighted fetal MRI and the correlation with placental dysfunction
    Baadsgaard, Kirstine
    Hansen, Ditte N.
    Peters, David A.
    Frokjaer, Jens B.
    Sinding, Marianne
    Sorensen, Anne
    PLACENTA, 2023, 131 : 90 - 97
  • [40] Fast T2*-Weighted MRI of the Prostate at 3 Tesla
    Hardman, Rulon L.
    El-Merhi, Fadi
    Jung, Adam J.
    Ware, Steve
    Thompson, Ian M.
    Friel, Harry T.
    Peng, Qi
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (04) : 902 - 907