T2*-weighted imaging for detection of intracranial silicone oil in MRI obtained with motion correction sequences

被引:0
|
作者
Yasuda, Ryuta [1 ,2 ]
Maeda, Masayuki [3 ,4 ]
Takada, Kenichi [3 ]
Inoue, Katsuhiro [4 ]
Sugao, Masataka [5 ]
Suzuki, Hidenori [2 ]
机构
[1] Tohyama Hosp, Dept Neurosurg, 17-22 Minami Shinmachi, Tsu, Mie 5140043, Japan
[2] Mie Univ, Grad Sch Med, Dept Neurosurg, 2-174 Edobashi, Tsu, Mie 5148507, Japan
[3] Tohyama Hosp, Dept Radiol, 17-22 Minami Shinmachi, Tsu, Mie 5140043, Japan
[4] Mie Univ, Grad Sch Med, Dept Neuroradiol, 2-174 Edobashi, Tsu, Mie 5148507, Japan
[5] Tohyama Hosp, Dept Internal Med, 17-22 Minami Shinmachi, Tsu, Mie 5140043, Japan
关键词
Silicone oil; Intracranial migration; T2*-weighted imaging; Motion correction sequence;
D O I
10.1186/s41984-025-00362-4
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BackgroundFor magnetic resonance imaging (MRI) findings of intracranial silicone oil migration, little has been described about images obtained with motion correction sequences such as MultiVane XD (Philips Healthcare) that provides high resolution diagnostic images even with severe patient motion. We report a case with intracranial silicone oil migration in which MRI was obtained with MultiVane XD and T2*-weighted imaging (T2*WI) was found the most useful in detecting intracranial silicone oil.Case presentationA 77-year-old female with a history of eye surgery using silicone oil referred to our hospital due to conscious disturbance. Head computed tomography demonstrated multiple intracranial masses whose signal density was similar to that in the operated eyeball and the tentative diagnosis of intracranial silicone oil migration was made. MRI was performed with MultiVane XD due to the significant patient's restlessness, and among all sequences including T1-weighted imaging (T1WI), T2-weighted imaging (T2WI), fluid-attenuated inversion recovery (FLAIR) and T2*WI, only T2*WI detected intracranial silicone oil. In contrast, another MRI obtained previously with conventional turbo spin-echo detected intracranial silicone oil not only in T2*WI but also in T1WI, T2WI and FLAIR. Phantom experiment revealed that chemical shift artifact played an important role in discriminating silicone oil from artificial cerebrospinal fluid, which attenuated in MultiVane XD. However, T2*WI still showed good discrimination of silicone oil even using MultiVane XD because of susceptibility artifacts.ConclusionT2*WI was the best sequence to detect intracranial silicone oil in MRI obtained with motion correction sequences because of its ability to depict the susceptibility artifacts.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] T2*-weighted MRI in cortical venous thrombosis
    Cakmak, S
    Hermier, M
    Montavont, A
    Derex, L
    Mauguière, F
    Trouillas, P
    Nighoghossian, N
    NEUROLOGY, 2004, 63 (09) : 1698 - 1698
  • [22] T2*-Weighted MRI Findings of Superficial Siderosis
    Yamamoto, Yu
    Yamamoto, Sayaka
    Kuroki, Shigehiro
    INTERNAL MEDICINE, 2012, 51 (14) : 1949 - 1949
  • [23] Author Correction: Optimisation of T2 and T2* sequences in MRI for better quantification of iron on transfused dependent sickle cell patients
    Azza Ahmed
    Amani Baldo
    A. Sulieman
    Hind Mirghani
    Fouad A. Abolaban
    I. I. Suliman
    Isam Salih
    Scientific Reports, 11
  • [24] Comparison of diffusion weighted imaging b0 with T2*-weighted gradient echo or susceptibility weighted imaging for intracranial hemorrhage detection after reperfusion therapy for ischemic stroke
    Luijten, Sven P. R.
    van der Ende, Nadinda A. M.
    Cornelissen, Sandra A. P.
    Kluijtmans, Leo
    van Hattem, Antonius
    Nijeholt, Geert
    Postma, Alida A.
    Bokkers, Reinoud P. H.
    Thomassen, Lars
    Waje-Andreassen, Ulrike
    Logallo, Nicola
    Bracard, Serge
    Gory, Benjamin
    Roozenbeek, Bob
    Dippel, Diederik W. J.
    van der Lugt, Aad
    NEURORADIOLOGY, 2023, 65 (11) : 1649 - 1655
  • [25] Hybrid Multidimensional T2 and Diffusion-Weighted MRI for Prostate Cancer Detection
    Wang, Shiyang
    Peng, Yahui
    Medved, Milica
    Yousuf, Ambereen N.
    Ivancevic, Marko K.
    Karademir, Ibrahim
    Jiang, Yulei
    Antic, Tatjana
    Sammet, Steffen
    Oto, Aytekin
    Karczmar, Gregory S.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (04) : 781 - 788
  • [26] Comparison of diffusion weighted imaging b0 with T2*-weighted gradient echo or susceptibility weighted imaging for intracranial hemorrhage detection after reperfusion therapy for ischemic stroke
    Sven P. R. Luijten
    Nadinda A. M. van der Ende
    Sandra A. P. Cornelissen
    Leo Kluijtmans
    Antonius van Hattem
    Geert Lycklama a Nijeholt
    Alida A. Postma
    Reinoud P. H. Bokkers
    Lars Thomassen
    Ulrike Waje-Andreassen
    Nicola Logallo
    Serge Bracard
    Benjamin Gory
    Bob Roozenbeek
    Diederik W. J. Dippel
    Aad van der Lugt
    Neuroradiology, 2023, 65 : 1649 - 1655
  • [27] T2-weighted MRI pulse sequences for imaging post-infarct edema in mice: comparison of spin echo and T2 preparation approaches
    Ronald J Beyers
    Yaqin Xu
    Frederick H Epstein
    Brent A French
    Journal of Cardiovascular Magnetic Resonance, 11 (Suppl 1)
  • [28] True FISP keyhole:: Fast T2 weighted imaging for interventional MRI at 0.2 T.
    Wendt, M
    Wacker, F
    Wolf, KJ
    Lewin, JS
    Duerk, JL
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 170 (04): : 391 - 393
  • [29] Navigator-Guided Motion and B0 Correction of T2*-Weighted Magnetic Resonance Imaging Improves Multiple Sclerosis Cortical Lesion Detection
    Liu, Jiaen
    Beck, Erin S.
    Filippini, Stefano
    van Gelderen, Peter
    de Zwart, Jacco A.
    Norato, Gina
    Sati, Pascal
    Al-Louzi, Omar
    Kolb, Hadar
    Donadieu, Maxime
    Morrison, Mark
    Duyn, Jeff H.
    Reich, Daniel S.
    INVESTIGATIVE RADIOLOGY, 2021, 56 (07) : 409 - 416
  • [30] A SIMPLE APPROACH TO T2 IMAGING IN MRI
    POPE, JM
    REPIN, N
    MAGNETIC RESONANCE IMAGING, 1988, 6 (06) : 641 - 646