T2*-weighted imaging for detection of intracranial silicone oil in MRI obtained with motion correction sequences

被引:0
|
作者
Yasuda, Ryuta [1 ,2 ]
Maeda, Masayuki [3 ,4 ]
Takada, Kenichi [3 ]
Inoue, Katsuhiro [4 ]
Sugao, Masataka [5 ]
Suzuki, Hidenori [2 ]
机构
[1] Tohyama Hosp, Dept Neurosurg, 17-22 Minami Shinmachi, Tsu, Mie 5140043, Japan
[2] Mie Univ, Grad Sch Med, Dept Neurosurg, 2-174 Edobashi, Tsu, Mie 5148507, Japan
[3] Tohyama Hosp, Dept Radiol, 17-22 Minami Shinmachi, Tsu, Mie 5140043, Japan
[4] Mie Univ, Grad Sch Med, Dept Neuroradiol, 2-174 Edobashi, Tsu, Mie 5148507, Japan
[5] Tohyama Hosp, Dept Internal Med, 17-22 Minami Shinmachi, Tsu, Mie 5140043, Japan
关键词
Silicone oil; Intracranial migration; T2*-weighted imaging; Motion correction sequence;
D O I
10.1186/s41984-025-00362-4
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BackgroundFor magnetic resonance imaging (MRI) findings of intracranial silicone oil migration, little has been described about images obtained with motion correction sequences such as MultiVane XD (Philips Healthcare) that provides high resolution diagnostic images even with severe patient motion. We report a case with intracranial silicone oil migration in which MRI was obtained with MultiVane XD and T2*-weighted imaging (T2*WI) was found the most useful in detecting intracranial silicone oil.Case presentationA 77-year-old female with a history of eye surgery using silicone oil referred to our hospital due to conscious disturbance. Head computed tomography demonstrated multiple intracranial masses whose signal density was similar to that in the operated eyeball and the tentative diagnosis of intracranial silicone oil migration was made. MRI was performed with MultiVane XD due to the significant patient's restlessness, and among all sequences including T1-weighted imaging (T1WI), T2-weighted imaging (T2WI), fluid-attenuated inversion recovery (FLAIR) and T2*WI, only T2*WI detected intracranial silicone oil. In contrast, another MRI obtained previously with conventional turbo spin-echo detected intracranial silicone oil not only in T2*WI but also in T1WI, T2WI and FLAIR. Phantom experiment revealed that chemical shift artifact played an important role in discriminating silicone oil from artificial cerebrospinal fluid, which attenuated in MultiVane XD. However, T2*WI still showed good discrimination of silicone oil even using MultiVane XD because of susceptibility artifacts.ConclusionT2*WI was the best sequence to detect intracranial silicone oil in MRI obtained with motion correction sequences because of its ability to depict the susceptibility artifacts.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] T2 and T2* mapping and weighted imaging in cardiac MRI
    Topriceanu, Constantin-Cristian
    Pierce, Iain
    Moon, James C.
    Captur, Gabriella
    MAGNETIC RESONANCE IMAGING, 2022, 93 : 15 - 32
  • [2] Imaging the ischaemic penumbra with T2* weighted MRI
    McCabe, Christopher
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2016, 36 (02): : 281 - 282
  • [3] High Accuracy of Magnetic Resonance T2*- Weighted Sequences for Detection of Intracranial Arterial Thrombus.
    Liberato, Afonso P.
    Shah, Santosh
    Maza, Noor
    Barnaure, Isabelle
    Gonzalez, Ramon G.
    Romero, Javier M.
    STROKE, 2016, 47
  • [4] T2*-Weighted Imaging Performance in the Detection of Deep Endometriosis among Readers with Different Experience: Comparison with Conventional MRI Sequences
    Franco, Paolo Niccolo
    Annibali, Simona
    Vigano, Sara
    Cazzella, Caterina
    Marra, Chiara
    Smedile, Antonella
    Bonaffini, Pietro Andrea
    Marra, Paolo
    Otero Garcia, Maria Milagros
    Reinhold, Caroline
    Sironi, Sandro
    DIAGNOSTICS, 2022, 12 (07)
  • [5] T2 mapping vs T2 weighted imaging in the detection of myocardial oedema
    Elisa McAlindon
    Peter Weale
    Jessica Harris
    David Smith
    Andreas Baumbach
    Tom Johnson
    Chiara Bucciarelli-Ducci
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [6] Automated detection of cerebral microbleeds on T2*-weighted MRI
    Anthony G. Chesebro
    Erica Amarante
    Patrick J. Lao
    Irene B. Meier
    Richard Mayeux
    Adam M. Brickman
    Scientific Reports, 11
  • [7] Usefulness of T2*-weighted MRI in the detection of adnexal torsion
    Kawai, Nobuyuki
    Kato, Hiroki
    Kanematsu, Masayuki
    Kawaguchi, Shimpei
    Kojima, Toshihisa
    Furui, Tatsuro
    Morishige, Ken-ichirou
    Matsuo, Masayuki
    ACTA RADIOLOGICA OPEN, 2016, 5 (06):
  • [8] Automated detection of cerebral microbleeds on T2*-weighted MRI
    Chesebro, Anthony G.
    Amarante, Erica
    Lao, Patrick J.
    Meier, Irene B.
    Mayeux, Richard
    Brickman, Adam M.
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [9] Clinical superiority of diffusion weighted imaging to T2 MRI alone in stroke detection and discrimination
    Lutsep, HL
    Albers, GW
    deCrespigny, A
    Moseley, ME
    NEUROLOGY, 1996, 46 (02) : 29005 - 29005
  • [10] Rapid T2*-weighted MRI using multishot EPI with retrospective motion and phase correction in the emergency department
    Li, Zhiqiang
    Ooi, Melvyn B.
    Murchison, James A.
    Karis, John P.
    MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (06) : 2500 - 2509