Performance optimization of new generation R290 and R1234yf refrigerants: A response surface methodology approach

被引:0
|
作者
Pektezel, Oguzhan [1 ]
Ozdemir, Safiye Nur [2 ]
机构
[1] Univ Balikesir, Dept Mech Engn, TR-10145 Balikesir, Turkiye
[2] Univ Sakarya, Dept Mech Engn, TR-54050 Adapazari, Turkiye
关键词
Experimental refrigeration system; Central composite design; Response surface methodology; Desirability function approach; Optimization process; MULTIOBJECTIVE OPTIMIZATION; ENERGY PERFORMANCE; GWP MIXTURES; SYSTEM; R134A; REPLACEMENT; IMPROVEMENT; R404A; ALTERNATIVES; R513A;
D O I
10.1016/j.applthermaleng.2025.125927
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study aims to perform the parametric optimization of the R290 and R1234yf refrigerants in vapor compression refrigeration systems by employing the Response surface methodology (RSM) approach to obtain the best operating conditions. The input factors, including evaporator and condenser temperatures, are first determined, ranging from -12 to -4 degrees C and 30 to 40 degrees C, respectively. The objective functions are also identified, including compressor discharge temperature (Tdis), refrigerant mass flow rate (mref), compressor power consumption (Pcomp), and coefficient of performance (COP). Then, the central composite design (CCD) was performed to set out the experimental investigations. Response surface methodology and analysis of variance were utilized to detect the optimal levels and analyze the individual and combined interaction between each pair of input factors. The novelty of this study is in applying the RSM technique to develop second-order regression models and utilizing the desirability function approach for optimizing the refrigeration system. The deviations between the predicted and experimental values for the compressor discharge temperature, refrigerant mass flow rate, compressor power consumption, and COP are 0.256 %, 0.292 %, 0.724 %, and 0.169 %, respectively, representing that this method efficiently optimizes the performance of the R290 refrigerant. Similarly, the deviations between the predicted and experimental values for R1234yf are as follows: 0.272 %, 0.526 %, 0.980 %, and 1.069 %. From our knowledge, there have been very few optimization studies on the thermodynamic performance of refrigerants using the RSM tool, which reduces experimental costs and saves time.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] 环保混合工质R290+R1234ze(E)/R1234yf的亥姆霍兹模型
    钟权
    董学强
    张海洋
    李会亚
    赵延兴
    沈俊
    公茂琼
    工程热物理学报, 2019, 40 (04) : 737 - 743
  • [42] Comparative Investigation on the Thermophysical Property and System Performance of R1234yf
    Li, Gailian
    Jin, Tingxiang
    Xu, Ran
    Lv, Zijian
    ENERGIES, 2023, 16 (13)
  • [43] Energy impact evaluation of different low-GWP alternatives to replace R134a in a beverage cooler. Experimental analysis and optimization for the pure refrigerants R152a, R1234yf, R290, R1270, R600a and R744
    Sánchez, D.
    Andreu-Nácher, A.
    Calleja-Anta, D.
    Llopis, R.
    Cabello, R.
    Energy Conversion and Management, 2022, 256
  • [44] Energy impact evaluation of different low-GWP alternatives to replace R134a in a beverage cooler. Experimental analysis and optimization for the pure refrigerants R152a, R1234yf, R290, R1270, R600a and R744
    Sanchez, D.
    Andreu-Nacher, A.
    Calleja-Anta, D.
    Llopis, R.
    Cabello, R.
    ENERGY CONVERSION AND MANAGEMENT, 2022, 256
  • [45] Optimal design and environmental, energy and exergy analysis of a vapor compression refrigeration system using R290, R1234yf, and R744 as alternatives to replace R134a
    de Paula, Cleison Henrique
    Duarte, Willian Moreira
    Martins Rocha, Thiago Torres
    de Oliveira, Raphael Nunes
    Torres Maia, Antonio Augusto
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 113 (113) : 10 - 20
  • [46] Condensation heat transfer of pure refrigerants R1234yf and R32 inside multiple circular minichannels
    Jige, Daisuke
    Mikajiri, Naoki
    Nobunaga, Maika
    Inoue, Norihiro
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2022, 195
  • [47] Performance Comparison of a Truck Refrigeration System with R404A, R134a, R1234yf, and R744 Refrigerants under Frosting Conditions
    Shin, Yunchan
    Cho, Honghyun
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2016, 24 (01)
  • [48] Experimental evaluation of NIR spectroscopic characteristics of liquid R32, R1234yf and R454C refrigerants
    Miyawaki, Kosuke
    Shikazono, Naoki
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 156
  • [49] Energetic and exergetic performance comparison o an experimental automotive air conditioning system using refrigerants R1234yf and R134a
    Alkan, Alpaslan
    Kolip, Ahmet
    Hosoz, Murat
    JOURNAL OF THERMAL ENGINEERING, 2021, 7 (05): : 1163 - 1173
  • [50] Performance Analysis of Low GWP Refrigerants R1234yf and R448A in a Small High and Low-temperature Test Equipment
    Liqiang Z.
    Zhang H.
    Zilong W.
    Wenjing G.
    Recent Patents on Mechanical Engineering, 2022, 15 (03) : 277 - 284