摘要
BackgroundThe selection of an implant is a critical factor in the surgical treatment of patella fractures due to the risk of various complications, such as non-union, implant failure, and irritation. The present study evaluated and compared the biomechanical strength of headless cannulated screws about screw length using the tension band wiring technique.MethodsForty-eight sawbone patellas with transverse fractures were divided into three fixation groups based on the screw length used in tension band wiring. Overall, three different fixation groups were determined: Group 1 (recessed headless cannulated screw fixation), Group 2 (full-length headless cannulated screw fixation), and Group 3 (protruding headless cannulated screw fixation). A setup was used to simulate a knee with a flexion angle of 60 degrees. Specimens underwent biomechanical testing under axial traction (static test) and cyclic loading (dynamic test). Displacements at 300 Newtons (N), loads at 2 millimetres (mm) displacement, and failure loads were documented for each sample in the static test. In the dynamic test protocol, 10,000 repetitive cycles were performed under physiological load between 100 and 300 N, and final displacements were recorded.ResultsThere were significant differences in the loads achieved at 2 mm displacement levels, and Group 3 demonstrated lower force values compared to other constructs in the static test (P = 0.003). All groups revealed similar displacements at 300 N and failure load values under axial traction. In the dynamic test, Group 3 had significantly higher fracture displacement under cyclic loading compared to the other specimens (P = 0.006).ConclusionsThis study found headless cannulated screws for transverse patella fracture fixation provide sufficient stability; however, protruding headless screws reduce the fixation strength. Recessed or full-length screws may improve stability and bony healing, potentially preventing complications in patella fractures.Level of evidenceBiomechanical study N/A.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Patella Fractures outcome after Tension Band Wiring; a Cross-sectional Study
    Kazemi, Seyyed-Morteza
    Qoreishi, Seyyed-Mohammad
    Keyhani, Sohrab
    Hosseininejad, Seyyed-Mohsen
    Noktehsanj, Reza
    JOURNAL OF PIONEERING MEDICAL SCIENCES, 2024, 13 (01): : 123 - 126
  • [42] Lateral rim variable angle locked plating versus tension band wiring of simple and complex patella fractures: a biomechanical study
    Stephen Warner
    Christoph Sommer
    Ivan Zderic
    William Woodburn
    Richard Castle
    Jessica Penman
    Eladio Saura-Sanchez
    David L. Helfet
    Boyko Gueorguiev
    Karl Stoffel
    Archives of Orthopaedic and Trauma Surgery, 2024, 144 : 2131 - 2140
  • [43] Lateral rim variable angle locked plating versus tension band wiring of simple and complex patella fractures: a biomechanical study
    Warner, Stephen
    Sommer, Christoph
    Zderic, Ivan
    Woodburn, William
    Castle, Richard
    Penman, Jessica
    Saura-Sanchez, Eladio
    Helfet, David L.
    Gueorguiev, Boyko
    Stoffel, Karl
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (05) : 2131 - 2140
  • [44] Cannulated versus non-cannulated cancellous screw fixation for femoral neck fractures: a synthetic bone biomechanical study
    Mutlu, Harun
    Mutlu, Serhat
    JOURNAL OF ORTHOPAEDIC SURGERY, 2015, 23 (02) : 271 - 271
  • [45] Fixation of Transverse Olecranon Fractures by Suture Bridge Method Using Suture Anchor: Biomechanical Comparison with Tension Band Wiring Technique
    Lee, Hyun Il
    Cho, Jin Ho
    Choi, Jun Young
    Lee, Sung Sahn
    Cho, Sung Tan
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2021, 26 (04): : 563 - 570
  • [46] Cannulated versus non-cannulated cancellous screw fixation for femoral neck fractures: a synthetic bone biomechanical study
    Gardner, A. W.
    Toh, M. Z.
    Yew, K. S. A.
    Lie, D. T. T.
    Chou, S. M.
    JOURNAL OF ORTHOPAEDIC SURGERY, 2015, 23 (01) : 41 - 46
  • [47] Biomechanical comparison of a new handy tension band with malleolar screw, bicortical screw and conventional tension band for the fixation of transverse medial malleolar fractures
    Kuru, Tolgahan
    Akpinar, Fuat
    Isik, Cengiz
    Ozkilic, Recai
    Ipek, Serdar
    Mutlu, Ibrahim
    Kizilay, Hasan
    EKLEM HASTALIKLARI VE CERRAHISI-JOINT DISEASES AND RELATED SURGERY, 2019, 30 (03): : 301 - 308
  • [48] A comparative study in fixation methods of medial malleolus fractures between tension bands wiring and screw fixation
    Mohammed, Ayyoub A.
    Abbas, Khalid Ahmed
    Mawlood, Ammar Salah
    SPRINGERPLUS, 2016, 5
  • [49] Abstaining from symptomatic implants of modified tension band wiring by nonabsorbable suture fixation for transverse patella fractures
    Jirangkul, Puripun
    Kosiyatrakul, Arkaphat
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [50] Abstaining from symptomatic implants of modified tension band wiring by nonabsorbable suture fixation for transverse patella fractures
    Puripun Jirangkul
    Arkaphat Kosiyatrakul
    Journal of Orthopaedic Surgery and Research, 16