Does protruding headless cannulated screw reduce fixation stability in tension band wiring technique for patella fractures? a biomechanical study

被引:0
|
作者
Maden, Mehmet [1 ]
Bayraktar, Omer Berkay [2 ]
Bacaksiz, Tayfun [2 ]
Akan, Ihsan [2 ]
Uzun, Bora [3 ]
Kazimoglu, Cemal [2 ]
机构
[1] Ataturk Training & Res Hosp, Dept Orthopaed & Traumatol, Izmir, Turkiye
[2] Izmir Katip Celebi Univ, Dept Orthopaed & Traumatol, Izmir, Turkiye
[3] Dokuz Eylul Univ, Dept Biomech, Izmir, Turkiye
来源
关键词
Patella fracture; Tension band wiring; Headless cannulated screw; Biomechanic; FIXED-ANGLE PLATE; INTERNAL-FIXATION; TRANSVERSE FRACTURES; NONUNION;
D O I
10.1186/s13018-025-05567-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundThe selection of an implant is a critical factor in the surgical treatment of patella fractures due to the risk of various complications, such as non-union, implant failure, and irritation. The present study evaluated and compared the biomechanical strength of headless cannulated screws about screw length using the tension band wiring technique.MethodsForty-eight sawbone patellas with transverse fractures were divided into three fixation groups based on the screw length used in tension band wiring. Overall, three different fixation groups were determined: Group 1 (recessed headless cannulated screw fixation), Group 2 (full-length headless cannulated screw fixation), and Group 3 (protruding headless cannulated screw fixation). A setup was used to simulate a knee with a flexion angle of 60 degrees. Specimens underwent biomechanical testing under axial traction (static test) and cyclic loading (dynamic test). Displacements at 300 Newtons (N), loads at 2 millimetres (mm) displacement, and failure loads were documented for each sample in the static test. In the dynamic test protocol, 10,000 repetitive cycles were performed under physiological load between 100 and 300 N, and final displacements were recorded.ResultsThere were significant differences in the loads achieved at 2 mm displacement levels, and Group 3 demonstrated lower force values compared to other constructs in the static test (P = 0.003). All groups revealed similar displacements at 300 N and failure load values under axial traction. In the dynamic test, Group 3 had significantly higher fracture displacement under cyclic loading compared to the other specimens (P = 0.006).ConclusionsThis study found headless cannulated screws for transverse patella fracture fixation provide sufficient stability; however, protruding headless screws reduce the fixation strength. Recessed or full-length screws may improve stability and bony healing, potentially preventing complications in patella fractures.Level of evidenceBiomechanical study N/A.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Treatment of displaced transverse fractures of the patella: modified tension band wiring technique with or without augmented circumferential cerclage wire fixation
    Yang, Tien-Yu
    Huang, Tsan-Wen
    Chuang, Po-Yao
    Huang, Kuo-Chin
    BMC MUSCULOSKELETAL DISORDERS, 2018, 19
  • [32] Tension-band wiring through a single cannulated screw combined with suture anchors to treat inferior pole fracture of the patella
    Liu, Chen-dong
    Hu, Sun-jun
    Chang, Shi-Min
    Du, Shou-chao
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54 (04): : 1203 - 1209
  • [33] Biomechanical comparison of three tension band wiring techniques for transverse fracture of patella: Kirschner wires, cannulated screws, and ring pins
    Lee, Kyung-Hag
    Lee, Yohan
    Lee, Young Ho
    Cho, Bong Wan
    Kim, Min Bom
    Baek, Goo Hyun
    JOURNAL OF ORTHOPAEDIC SURGERY, 2019, 27 (03)
  • [34] Olecranon fractures: A biomechanical comparison of three tension band wiring fixation methods on bone models
    Calisal, Emre
    Ugur, Levent
    JOURNAL OF ORTHOPAEDIC SURGERY, 2023, 31 (03)
  • [35] Biomechanical comparison of tension band wiring and plate fixation with locking screws in transverse olecranon fractures
    Midtgaard, Kaare Sourin
    Soreide, Endre
    Brattgjerd, Jan Egil
    Moatshe, Gilbert
    Madsen, Jan Erik
    Flugsrud, Gunnar B.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2020, 29 (06) : 1242 - 1248
  • [36] Biomechanical Evaluation of Transverse Patella Fracture Fixation Using Headless Screws: A Comparison of Suture Versus Cable as a Tension Band
    Bric, Justin D.
    Martin, Jill M.
    McGrady, Linda M.
    Wang, Mei
    Schmeling, Gregory J.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2023, 37 (06) : E253 - E257
  • [37] A retrospective comparison of the modified tension band technique and the parallel titanium cannulated lag screw technique in transverse patella fracture
    Wang Chengxue
    Tan Lei
    Qi Baochang
    Hou Xiangfeng
    Huang Yulong
    Zhang Haipeng
    Yu Tiecheng
    CHINESE JOURNAL OF TRAUMATOLOGY, 2014, 17 (04) : 208 - 213
  • [38] A retrospective comparison of the modified tension band technique and the parallel titanium cannulated lag screw technique in transverse patella fracture
    Wang Chengxue
    Tan Lei
    Qi Baochang
    Hou Xiangfeng
    Huang Yulong
    Zhang Haipeng
    Yu Tiecheng
    中华创伤杂志(英文版), 2014, 17 (04) : 208 - 213
  • [39] Biomechanical comparison of a novel tensioned cable construct versus tension band wiring for transverse patella fracture fixation
    Benjamin D. Kagan
    Alec D. Sundet
    Mack Gardner-Morse
    Pirapon L. Chaidarun
    Bruce D. Beynnon
    Patrick C. Schottel
    European Journal of Orthopaedic Surgery & Traumatology, 2023, 33 : 1573 - 1580
  • [40] Biomechanical comparison of a novel tensioned cable construct versus tension band wiring for transverse patella fracture fixation
    Kagan, Benjamin D.
    Sundet, Alec D.
    Gardner-Morse, Mack
    Chaidarun, Pirapon L.
    Beynnon, Bruce D.
    Schottel, Patrick C.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2023, 33 (05): : 1573 - 1580