Does protruding headless cannulated screw reduce fixation stability in tension band wiring technique for patella fractures? a biomechanical study

被引:0
|
作者
Maden, Mehmet [1 ]
Bayraktar, Omer Berkay [2 ]
Bacaksiz, Tayfun [2 ]
Akan, Ihsan [2 ]
Uzun, Bora [3 ]
Kazimoglu, Cemal [2 ]
机构
[1] Ataturk Training & Res Hosp, Dept Orthopaed & Traumatol, Izmir, Turkiye
[2] Izmir Katip Celebi Univ, Dept Orthopaed & Traumatol, Izmir, Turkiye
[3] Dokuz Eylul Univ, Dept Biomech, Izmir, Turkiye
来源
关键词
Patella fracture; Tension band wiring; Headless cannulated screw; Biomechanic; FIXED-ANGLE PLATE; INTERNAL-FIXATION; TRANSVERSE FRACTURES; NONUNION;
D O I
10.1186/s13018-025-05567-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundThe selection of an implant is a critical factor in the surgical treatment of patella fractures due to the risk of various complications, such as non-union, implant failure, and irritation. The present study evaluated and compared the biomechanical strength of headless cannulated screws about screw length using the tension band wiring technique.MethodsForty-eight sawbone patellas with transverse fractures were divided into three fixation groups based on the screw length used in tension band wiring. Overall, three different fixation groups were determined: Group 1 (recessed headless cannulated screw fixation), Group 2 (full-length headless cannulated screw fixation), and Group 3 (protruding headless cannulated screw fixation). A setup was used to simulate a knee with a flexion angle of 60 degrees. Specimens underwent biomechanical testing under axial traction (static test) and cyclic loading (dynamic test). Displacements at 300 Newtons (N), loads at 2 millimetres (mm) displacement, and failure loads were documented for each sample in the static test. In the dynamic test protocol, 10,000 repetitive cycles were performed under physiological load between 100 and 300 N, and final displacements were recorded.ResultsThere were significant differences in the loads achieved at 2 mm displacement levels, and Group 3 demonstrated lower force values compared to other constructs in the static test (P = 0.003). All groups revealed similar displacements at 300 N and failure load values under axial traction. In the dynamic test, Group 3 had significantly higher fracture displacement under cyclic loading compared to the other specimens (P = 0.006).ConclusionsThis study found headless cannulated screws for transverse patella fracture fixation provide sufficient stability; however, protruding headless screws reduce the fixation strength. Recessed or full-length screws may improve stability and bony healing, potentially preventing complications in patella fractures.Level of evidenceBiomechanical study N/A.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Comparison of Cannulated Screw With Tension Band Wiring Versus Compressive Cannulated Locking Bolt and Nut Device (CompresSURE) in Patella Fractures-A Cadaveric Biomechanical Study
    Domby, Brian
    Henderson, Eric
    Nayak, Aniruddh
    Erdogan, Murat
    Gutierrez, Sergio
    Santoni, Brandon G.
    Sagi, H. Claude
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2012, 26 (12) : 678 - 683
  • [2] Treatment of longitudinal fractures of patella by percutaneous cannulated screws with tension band wiring technique
    Cheng, Anyuan
    Xu, Fusheng
    Huang, Zifeng
    Xu, Li
    Shi, Chen
    Zhang, Wei
    Song, Qi
    MINERVA ORTHOPEDICS, 2021, 72 (04): : 407 - 411
  • [3] Internal Fixation of Transverse Patella Fractures Using Cannulated Cancellous Screws with Anterior Tension Band Wiring
    Khan, I
    Dar, M. Y.
    Rashid, S.
    Butt, M. F.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2016, 10 (02) : 21 - 26
  • [4] Biomechanical comparison of a new staple technique with tension band wiring for transverse patella fractures
    Schnabel, Bernd
    Scharf, Martin
    Schwieger, Karsten
    Windolf, Markus
    van der Pol, Bas
    Braunstein, Volker
    Appelt, Andreas
    CLINICAL BIOMECHANICS, 2009, 24 (10) : 855 - 859
  • [5] Screw fixation as an alternative to tension band wiring in displaced transverse patella fractures: a retrospective, single center study
    Rahm, S.
    Lionetto, S.
    Hotz, T.
    Kaech, K.
    BRITISH JOURNAL OF SURGERY, 2010, 97 : 21 - 21
  • [6] Biomechanical analysis of tension band wiring (TBW) of transverse fractures of patella
    Ali, Mohammed
    Kuiper, Jan
    John, Joby
    CHINESE JOURNAL OF TRAUMATOLOGY, 2016, 19 (05) : 255 - 258
  • [7] Biomechanical analysis of tension band wiring (TBW) of transverse fractures of patella
    Ali Mohammed
    Kuiper Jan
    John Joby
    中华创伤杂志英文版, 2016, 19 (05) : 255 - 258
  • [8] Suture tension band fixation vs. metallic tension band wiring for patella fractures - A biomechanical study on 19 human cadaveric patellae
    Adjal, Jonas
    Haugaard, Asger
    Vesterby, Liv
    Ibrahim, Huda Muhudin
    Sert, Kevser
    Thomsen, Morten Grove
    Tengberg, Peter Toft
    Ban, Ilija
    Ohrt-Nissen, Soren
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (08): : 2749 - 2753
  • [9] Biomechanical comparison of tension band suture fixation and tension band wiring in olecranon fractures
    Vesterby, Liv
    Haugaard, Asger Martin
    Adjal, Jonas
    Muhudin, Huda Ibrahim
    Sert, Kevser
    Thomsen, Morten Grove
    Ban, Ilija
    Ohrt-Nissen, Soren
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54 (08):
  • [10] Cannulated screw fixation of Jones fractures - A clinical and biomechanical study
    Reese, K
    Litsky, A
    Kaeding, C
    Pedroza, A
    Shah, N
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2004, 32 (07): : 1736 - 1742