Modelling transthoracic defibrillation waveforms

被引:7
|
作者
Krasteva, V. [1 ]
Cansell, A. [1 ]
Daskalov, I. [1 ]
机构
[1] Centre of Biomedical Engineering, Bulgarian Academy of Sciences, Sofia 1113, Bulgaria
来源
关键词
Transmembrane voltage - Transthoracic defibrillators;
D O I
10.1080/030919000409320
中图分类号
学科分类号
摘要
Recent investigations connected with implantable defibrillators yielded new data on heart electrophysiology, resulting in reassessment of existing and advancing of new types of electrical impulses. Different electrical equivalent circuits were proposed for modelling intracardiac and transthoracic defibrillation pulse waveforms, comprising generator, electrode interface and tissue resistances. We attempted modelling of the transmembrane voltage V(m) time course, induced by different applied voltage V(s) waveforms, taking into account only the shapes and the relative V(s) and V(m) amplitudes. The excitable cell membrane impedance Z(m) was modelled with higher resistance and lower capacitance, so that a shunting effect on the generator and tissue resistances was avoided. The result was a very simple equivalent circuit. We proposed criteria for efficient defibrillation pulse waveforms yielding a straightforward approach to model existing and new pulses and to assess their efficiency.
引用
收藏
页码:63 / 67
相关论文
共 50 条
  • [41] Improved defibrillation efficacy with triphasic waveforms
    Huang, J
    Kenknight, BH
    Smith, WM
    Ideker, RE
    CIRCULATION, 1997, 96 (08) : 3243 - 3243
  • [42] Comparison between two defibrillation waveforms
    Kostov J.
    Mudrov T.
    Dotsinsky I.
    Mudrov N.
    Journal of Medical Engineering and Technology, 2010, 34 (7-8): : 429 - 436
  • [43] A comparison of endocardial defibrillation with three transthoracic defibrillation configurations in a porcine model
    Michael, K. A.
    Paisey, J. R.
    Bullens, R. W.
    Smits, K. F.
    Roberts, P. R.
    Morgan, J. M.
    CANADIAN JOURNAL OF CARDIOLOGY, 2007, 23 : 207C - 207C
  • [44] Computer modelling of transthoracic electric field during defibrillation shocks: An efficient finite difference implementation
    Malik, M
    Smits, KFAA
    Lindemans, F
    COMPUTERS IN CARDIOLOGY 1997, VOL 24, 1997, 24 : 255 - 258
  • [45] TRANS-THORACIC DEFIBRILLATION THRESHOLD OF SINE AND TRAPEZOIDAL WAVEFORMS IN DEFIBRILLATION
    WILSON, CM
    BAILEY, A
    ALLEN, JD
    ANDERSON, J
    ADGEY, AAJ
    JOURNAL OF ELECTROCARDIOLOGY, 1989, 22 (03) : 241 - 247
  • [46] Tuned defibrillation waveforms outperform 50/50% tilt defibrillation waveforms: A randomized multi-center study
    Natarajan, Senthil
    Henthorn, Richard
    Burroughs, Jefferson
    Esberg, Douglas
    Zweibel, Steven
    Ross, Terence
    Kroll, Mark
    Gianola, Don
    Oza, Ashish
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2007, 30 : S139 - S142
  • [47] First-time evaluation of ascending compared to rectangular transthoracic defibrillation waveforms in modelled out-of-hospital cardiac arrest
    Neumann, Tobias
    Finke, Simon-Richard
    Henninger, Maja
    Lemke, Sebastian
    Hoepfner, Ben
    Steven, Daniel
    Maul, Alexandra C.
    Schroeder, Daniel C.
    Annecke, Thorsten
    RESUSCITATION PLUS, 2020, 1-2
  • [48] Transthoracic biphasic waveform defibrillation at very high and very low energies: a comparison with monophasic waveforms in an animal model of ventricular fibrillation
    Clark, CB
    Zhang, Y
    Davies, LR
    Karlsson, G
    Kerber, RE
    RESUSCITATION, 2002, 54 (02) : 183 - 186
  • [49] EFFECT OF EPICARDIAL PATCH ELECTRODES ON TRANSTHORACIC DEFIBRILLATION
    LERMAN, BB
    DEALE, OC
    CIRCULATION, 1990, 81 (04) : 1409 - 1414
  • [50] Possibilities for predictive measurement of the transthoracic impedance in defibrillation
    Krasteva, V
    Al Hatib, F
    Trendafilova, E
    Daskalov, I
    JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 2001, 25 (05) : 195 - 200