Modelling transthoracic defibrillation waveforms

被引:7
|
作者
Krasteva, V. [1 ]
Cansell, A. [1 ]
Daskalov, I. [1 ]
机构
[1] Centre of Biomedical Engineering, Bulgarian Academy of Sciences, Sofia 1113, Bulgaria
来源
关键词
Transmembrane voltage - Transthoracic defibrillators;
D O I
10.1080/030919000409320
中图分类号
学科分类号
摘要
Recent investigations connected with implantable defibrillators yielded new data on heart electrophysiology, resulting in reassessment of existing and advancing of new types of electrical impulses. Different electrical equivalent circuits were proposed for modelling intracardiac and transthoracic defibrillation pulse waveforms, comprising generator, electrode interface and tissue resistances. We attempted modelling of the transmembrane voltage V(m) time course, induced by different applied voltage V(s) waveforms, taking into account only the shapes and the relative V(s) and V(m) amplitudes. The excitable cell membrane impedance Z(m) was modelled with higher resistance and lower capacitance, so that a shunting effect on the generator and tissue resistances was avoided. The result was a very simple equivalent circuit. We proposed criteria for efficient defibrillation pulse waveforms yielding a straightforward approach to model existing and new pulses and to assess their efficiency.
引用
收藏
页码:63 / 67
相关论文
共 50 条
  • [31] Optimizing defibrillation waveforms for ICDs
    Kroll, Mark W.
    Swerdlow, Charles D.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2007, 18 (03) : 247 - 263
  • [32] Three-dimensional Finite Element Modelling of Current Density in Maternal Transthoracic Defibrillation
    Jeremic, A.
    Pots, J.
    Khosroshahli, E.
    PIERS 2012 MOSCOW: PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM, 2012, : 334 - 338
  • [33] Immediate defibrillation predicts probability of defibrillation curve width for external defibrillation waveforms
    Tovar, OH
    Snyder, DE
    Jones, JL
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 351A - 351A
  • [34] Transthoracic defibrillation: Does electrode position alter transthoracic impedance?
    Garcia, LA
    Kerber, RE
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 93362 - 93362
  • [35] TRANSTHORACIC VENTRICULAR DEFIBRILLATION WITH SQUARE-WAVE STIMULI - 1-HALF CYCLE 1 CYCLE + MULTICYCLE WAVEFORMS
    SCHUDER, JC
    DOLAN, AM
    STOECKLE, H
    CIRCULATION RESEARCH, 1964, 15 (03) : 258 - &
  • [36] Current-based transthoracic defibrillation
    Kerber, RE
    Kieso, RA
    Kienzle, MG
    Olshansky, B
    Waldo, AL
    Carlson, MD
    Wilber, DJ
    Aschoff, AM
    Birger, S
    Charbonnier, F
    AMERICAN JOURNAL OF CARDIOLOGY, 1996, 78 (10): : 1113 - 1118
  • [37] Evaluation of three transthoracic defibrillation configurations
    Michael, K. A.
    Paisey, J. R.
    Baranchuk, A.
    Bullens, R. W. M.
    Smits, K. F. F. A.
    Sunni, N. S.
    Yue, A. M.
    Roberts, P. R.
    Morgan, J. M. M.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 : S92 - S92
  • [38] TRUNCATED BIPHASIC PULSES FOR TRANSTHORACIC DEFIBRILLATION
    BARDY, GH
    GLINER, BE
    KUDENCHUK, PJ
    POOLE, JE
    DOLACK, GL
    JONES, GK
    ANDERSON, J
    TROUTMAN, C
    JOHNSON, G
    CIRCULATION, 1995, 91 (06) : 1768 - 1774
  • [39] CURRENT-BASED TRANSTHORACIC DEFIBRILLATION IS SUPERIOR TO ENERGY-BASED DEFIBRILLATION IN PATIENTS WITH HIGH TRANSTHORACIC IMPEDANCE
    KERBER, RE
    KIENZLE, MG
    OLSHANSKY, B
    CARLSON, MD
    WALDO, AL
    WILBER, D
    ASCHOFF, AM
    BIRGER, S
    WALSH, S
    FOXEASTHAM, K
    ROCKWELL, M
    CHARBONNIER, F
    CLINICAL RESEARCH, 1991, 39 (03): : A690 - A690
  • [40] Comparison of two biphasic waveforms for defibrillation
    Chang, YT
    Tang, WC
    Wang, JL
    Brewer, JE
    Freeman, G
    Sun, SJ
    Huang, L
    Well, MH
    CIRCULATION, 2005, 112 (17) : U1183 - U1183