POSITION RESOLUTION IN SILICON SAMPLING CALORIMETERS.

被引:0
|
作者
Coon, D.D. [1 ]
Liu, L.Z. [1 ]
机构
[1] Univ of Pittsburgh, Pittsburgh, PA,, USA, Univ of Pittsburgh, Pittsburgh, PA, USA
来源
关键词
PHYSICS - High Energy - RADIATION DETECTORS;
D O I
暂无
中图分类号
学科分类号
摘要
Due to the coupling between closely spaced detectors, the position resolution of a silicon sampling calorimeter can be degraded. In a capacitance coupling model, a Green's function is found which quantitatively describes signal spreading over two-dimensional detector arrays. The result provides some theoretical guidance in choosing calorimeter parameters to get the best performance.
引用
收藏
页码:457 / 460
相关论文
共 50 条
  • [21] Evaluation of carbon dioxide excretion measurement accuracy for two calorimeters.
    Orr, J
    Sherman, M
    Brewer, L
    CRITICAL CARE MEDICINE, 2005, 33 (12) : A116 - A116
  • [22] HIGH RESISTANCE LEAD GLASS TUBING FOR RICH COUNTERS AND FOR ELECTROMAGNETIC CALORIMETERS.
    Del Guerra, A.
    Conti, M.
    Gorini, G.
    Fujieda, I.
    Mulera, T.A.
    Perez-Mendez, V.
    Nuclear instruments and methods in physics research, 1986, A257 (03): : 609 - 613
  • [23] RADIAL DISTRIBUTIONS OF SHOWER ENERGY RELEASE IN HODOSCOPIC HADRON AND PHOTON CALORIMETERS.
    Baishev, I.S.
    Mokhov, N.V.
    Semenov, V.K.
    Instruments and experimental techniques New York, 1986, 29 (3 pt 1): : 568 - 572
  • [24] ALICE Zero Degree Calorimeters. The new readout system in LHC Run 3
    Zugravel, S. C.
    Cortese, P.
    Cotto, G.
    Marco, N. De
    Remigis, P. De
    Lombardo, L.
    Mazza, G.
    Puggioni, C.
    Puleo, E.
    Quaglia, L.
    Sitta, M.
    JOURNAL OF INSTRUMENTATION, 2023, 18 (02):
  • [25] Silicon Calorimeters
    Brient, J. -C.
    Rusack, R.
    Sefkow, F.
    ANNUAL REVIEW OF NUCLEAR AND PARTICLE SCIENCE, VOL 68, 2018, 68 : 271 - 290
  • [26] The ATLAS liquid argon calorimeters. Commissioning and performances from selected test beams
    Iconomidou-Fayard, Lydia
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 1959 - 1963
  • [27] EFFECT OF ENERGY LEAKAGE ON THE ENERGY RESOLUTION OF E.M. SAMPLING CALORIMETERS
    Gavrishchuk, O. P.
    Kovtun, V. E.
    Malykhina, T., V
    PROBLEMS OF ATOMIC SCIENCE AND TECHNOLOGY, 2021, (03): : 76 - 80
  • [28] OPTIMIZATION OF ELECTROMAGNETIC SAMPLING CALORIMETERS
    PRABHAHARAN, A
    BUGGE, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 314 (01): : 21 - 25
  • [29] CERENKOV FIBER SAMPLING CALORIMETERS
    ARRINGTON, K
    KEFFORD, D
    KENNEDY, J
    PISANI, R
    SANZENI, C
    SEGALL, K
    WALL, D
    WINN, DR
    CAREY, R
    DYE, S
    MILLER, J
    SULAK, L
    WORSTELL, W
    EFREMENKO, Y
    KAMYSHKOV, Y
    SAVIN, A
    SHMAKOV, K
    TARKOVSKY, E
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) : 840 - 844
  • [30] Sampling Fluctuations in Electromagnetic Calorimeters
    Denisov, S. P.
    Goryachev, V. N.
    PHYSICS OF ATOMIC NUCLEI, 2021, 84 (09) : 1577 - 1579